System Intercom Llais Dwy Ffordd Amser Real Digidol Di-wifr UniTalk UT-001

About UniTalk
We have been committed to wireless technology research, innovation and development of excellent wireless products.
We have a professional technical research and development team, pursuing product characteristics and customer experience, paying attention to every feedback and improving products in time to meet customer needs.
Cyflwyniadau cynnyrch
The wireless digital full-duplex real-time two-way voice intercom system with offline voice control for home and office use is to serve you perfectly wherever you are. This is an unprecedented indoor wireless intercom system product, it will bid farewell to the traditional use of intercom, perfect auto answer and hands-free function, and easy monitoring of children or the elderly to avoid emergency situations. The wireless intercom system uses the advanced Digital Enhanced Cordless Telecommunications (DECT) and the high-fidelity processing technology, sound quality is clear, avoid interference, and make your communication more stable and confidential.
Offline Voice Command Control– The offline voice command control does not require a connection to a WIFI network and is not limited by the usage environment. The biggest significance of offline voice command control is that it can completely free your hands and make it easy to operate. Suitable for people with limited mobility.
Ateb Awtomatig– Usually, we use the intercom that we need to press the call button on the intercom before making a call. The automatic answering function can answer automatically without pressing the answer button.
Audible and visual prompts– Incoming calls with sound and light prompts are more friendly for people with hearing or visual impairments.
Group call- The Group call function that can support one to many calls at the same time.
Monitor function- Easy monitoring of children or the elderly to avoid emergency situations.
Long Distance Wireless- The wireless communication range between FP (Base) and PP unit can up to 1/4mile (400 Meters) in a clear or unobstructed space. If based on the FP (Base) unit as the center, the distance between PP and PP unit can be extended to 1/2mile (800 Meters).
Hawdd i'w Gosod & expandable- This system is plug and play that easy to install and expandable that can be set up within minutes.
Drosoddview


Arddangosfa LCD

Modd Wrth Gefn: LCD backlight is not lit
Modd Gweithredol: LCD displays Ice blue/Green backlight
Nodyn: Ice blue backlight for FP (Base) unit Green backlit
Cyfarwyddiadau Gweithredu
Pŵer Ymlaen / Diffodd
The intercom will power on automatically and the LCD screen will be lighted when the USB 5V is plug in.
Pwyswch a dal y
(Hang up) for 3 seconds to turn on/off the intercom.
Set up the intercom
This intercom system is already paired before leaving the factory and users can plug and play it.
Nodyn: If the user needs to add a new PP unit that must to be paired and registered on the FP (Base) unit before use.
- a. How to identify FP (Base) unit and PP units?
Plug in the USB power and then turn on the intercom, The LCD backlight of the FP(Base) unit will display ice blue and the unit number defaults is 0. The LCD backlight of PP unit will display green and the unit number will be assigned to 1-5. - b. Paring method for registration on FP (Base) unit
Press and hold the VOL+/VOL- button on the FP and PP units respectively for 3 seconds to enter pairing mode, and the icon on LCD will flash. You can hear a successful pairing prompt tone, the system will automatically assign a unit number to the PP unit and the corresponding unit number will be displayed on the LCD.
Please record the unit number of each office / room as following to enable you to rapidly and accurately call others.
| Sianel | 0 | 1 | 2 | 3 | 4 | 5 |
| Categori | FP (Base Unit) | PP | PP | PP | PP | PP |
| Lleoliad Dyfais | Stafell Fyw | Ystafell Fwyta | Ystafell wely | Cegin | garej | Ystafell Astudio |
Full duplex call mode (one-to-one)
- a. If there are only 2 units (1 FP+1 PP), pressing the
(Call) button can make the call directly. - b. If there are multiple devices, you can press the unit number of that you want to call to make a call directly.
- c. When the called party intercom receives the incoming call signal, it will ring and the unit number of the incoming call will be flashing on the LCD screen. The unit will auto answer if the auto answer function is enabled (Default is enabled) or press the Call button to answer if the auto answer function is disabled.
- d. If the auto answer function is disabled and you do not answer the call after ringing for 40 seconds, the intercom will exit and return to the standby mode automatically.
- e. In the calling mode, either party presses the Hung-up button to end the call.
Galwad Grŵp
The intercom has a Group call function that can support one to many calls, you just need to press the
(Group) button to call all online stations at the same time.
Nodyn: The Group call function can only support simultaneous talking between 5 units (1 FP + 4 PP units).
Monitor/VOX (Voice Operated Exchanged) Function
The intercom has a monitor function, which you can use for an elderly care and baby monitor. In order to improve the noise issue during monitoring that you can switch to VOX mode. If the VOX is turned on, as long as the microphone of the intercom detects a speaking sound, it will automatically turn on transmission, achieving “voice controlled” calls.
When the microphone cannot hear sound, the speaker will be muted and will not disturb your rest.
Yn gyntaf pwyswch y
(Monitor) button enter the monitor mode and then press unit number 0-5 to specify the authorized devices allowed to be monitored. The icon of monitor on the LCD will illuminate to indicate this status.
Am gynample, the PP unit (1#) is in the baby room and the FP unit (0#) is in the primary bedroom. In order to protect user privacy, if the parents want to monitor the sound of the baby room, they need to press the Monitor button on the PP unit (1#) in the baby room and then select the unit number with 0(FP unit), and then they can monitor the sound of the baby room in the primary bedroom. If you want to switch to VOX mode during monitoring mode, you only need to press and hold the Monitor button on the FP unit for 3 seconds to enter the VOX mode and the VOX icon on the LCD will light up.
Nodyn: This monitoring function can work continuously.
Rheoli Lefel Cyfrol
Gwasgwch y VOL + / VOL- button to adjust the volume level of the ringing tone in standby mode.
Gwasgwch y VOL + / VOL- button to change the volume level of call in the calling mode.
Nodwyd: There are 6 levels of volume control, 1 is the minimum, 6 is the maximum.
Gosod Ateb Awtomatig
The auto answer function is enabled by default that can completely free your hands to realize full-duplex real-time hands-free call. The recipient does not need to press the Call button to answer the call, the intercom will answer automatically after three rings.
- a. Press and hold the VOL- button for 3 second to disable the auto answer function that you can head a voice prompt with auto answer turned off.
- b. Press and hold the VOL- button for 3 second again to enable the auto answer function that you can head a voice prompt with auto answer turned on.
Howling Detect
There will produce a whistling sound when two intercoms are in close proximity during a conversation, so the intercom has a built-in the howling detect function that it will temporarily mute the output of speaker for 5 seconds after detecting howling to avoid the whistling sound, there will display a flashing “H” on the LCD at the same time.
The howling detect function is enabled by default, you can press and hold the VOL+ button for 3 seconds to turn on/off the function and there will be a prompt sound with howling detect turned on/off.
Chimes Selection
Press the Chimes button to change the ringtone between 0-9 that you want to specify your preferred ringtone.
Nodyn: This intercom has built-in 10 chimes that you can to choose from.
Mic Mute function
Short press the MUTE button in calling mode to enter MIC mute mode. Press the Mute button again to unmute.
Nodyn: An icon with U will be displayed on the LCD and the backlight of LCD will flash when the microphone is muted.
Ambience light setting
Press and hold the Light button to turn on/off the ambience light.
Short press the Light button to change the color of the ambience light from Green → Ice blue → Blue → Purple → Red → Emerald green.
Nodyn: In order to save power and extend battery life, the ambient light is turned off by default.
Charging and Low battery prompt (For battery version only)
Dangosydd tâl
During the charging process, the battery symbol
is displayed in a cyclic manner.
After being fully charged, the battery symbol
stops cycling.
Dangosydd Batri Isel
Symbol y batri
on the LCD flashes and emits a low battery prompt sound.
Please charge in a timely manner, otherwise it will automatically shut down.
Rheoli Llais All-lein
This intercom is equipped with an offline voice recognition chip and you can control this unit with voice commands, which can completely free up your hands and be more friendly to people with limited mobility.
First you need to say the wake-up word with Hi UniTalk to wake up the unit and then say the command word to execute the corresponding function.
Please refer to below voice command for details.
| Nac ydw | Geiriau Gorchymyn | Math Swyddogaeth | Playback Sentence |
| 1 | HI-UniTalk | Gair deffro | Hi, how can I help you? |
| 2 | CALL-UNIT-ONE | Gair gorchymyn | Calling unit one |
| 3 | CALL-UNIT -TWO | Gair gorchymyn | Calling unit two |
| 4 | CALL-UNIT -THREE | Gair gorchymyn | Calling unit three |
| 5 | CALL-UNIT -FOUR | Gair gorchymyn | Calling unit four |
| 6 | CALL-UNIT -FIVE | Gair gorchymyn | Calling unit five |
| 7 | CALL-BASE-UNIT | Gair gorchymyn | Calling base unit |
| 8 | MONITOR-UNIT -ONE | Gair gorchymyn | Start Monitoring unit one |
| 9 | MONITOR-UNIT -TWO | Gair gorchymyn | Start Monitoring unit two |
| 10 | MONITOR-UNIT -THREE | Gair gorchymyn | Start Monitoring unit three |
| 11 | MONITOR-UNIT -FOUR | Gair gorchymyn | Start Monitoring unit four |
| 12 | MONITOR-UNIT -FIVE | Gair gorchymyn | Start Monitoring unit five |
| 13 | MONITOR-BASE-UNIT | Gair gorchymyn | Start Monitoring base unit |
| 14 | GROUP-CALL | Gair gorchymyn | Start Group call |
| 15 | GOLAU-AR | Gair gorchymyn | Light turned on |
| 16 | GOLAU-OFF | Gair gorchymyn | Light turned off |
| 17 | CYFROL-I FYNY | Gair gorchymyn | Volume turned up |
| 18 | CYFROL-DOWN | Gair gorchymyn | Cyfrol wedi'i gwrthod |
| 19 | MAXIMUM-VOLUME | Gair gorchymyn | Volume at maximum |
| 20 | LLEIAF-GYFROL | Gair gorchymyn | Cyfaint o leiaf |
| 21 | PWER I FFWRDD | Gair gorchymyn | Mae pŵer i ffwrdd |
| 22 | Welcoming speech | Welcome to UniTalk, please say Hi UniTalk to wake me up. | |
| 23 | Resting language | Honey, I’m resting now. |
Wireless Transmission Distance Expansion
The wireless communication range between FP and PP unit can up to 1/4mile (400 Meters) in a clear or unobstructed space.
If based on the FP (Base) unit as the center, the distance between PP and PP unit can be extended to 1/2mile (800 Meters).

Clear pairing records on the FP (Base) unit
Press and hold the VOL+/VOL- on the FP(Base) unit at the same time for 3 seconds and then press the MUTE button continuously 7 times to clear pairing records.
Nodyn: If you want to continue using it, you need to refer to the previous Set up the intercom section to re-pair it.
How to installation the intercom
- a. Place on the desktop

- b. Hang on the wall

Paramedrau Technegol
Model Rhif .: UT-001
Cyflenwad Pŵer: DC 5V/1A Input with 6 feet (1.8 meters) USB Type C cable.
Built in Battery (For Battery Version only):
3.7V/2000mAh for FP (Base) Unit
3.7V/1200mAh for PP Unit
Bywyd batri: Can talk continuously for 14 hours (For Battery Version only)
Pellter Trosglwyddo Di-wifr: The distance between FP(Base) and PP unit is ≥1/4 mile(400 Meters) in a clear or unobstructed space.
Nodyn: The distance between PP and PP can be extended to 1/2mile (800 Meters) if the FP(Base) unit is placed in the center position.
Amlder Gwaith:
1921.536MHz-1928.448MHz for US
Tymheredd Gwaith:
-4 °F to 140 °F(-20 °C to +60 °C) for working
32°F to 113 °F (0 °C to +45 °C) for battery charging
Datrys problemau
The intercom can’t power on
- a. Check if the USB cable is connected correctly. Or replace another USB cable for testing. It can help us understand whether the problem is on USB cable or the intercom.
- b. Check if the battery is fully charged. (For Battery Version Only)
- c. If the problem has not been improved, please contact us to obtain our technical support or replace the faulty unit.
Cannot talk to another intercom
- a. Please refer to the operating instructions → Set up the intercom to make sure the both intercoms are paired properly.
- b. Please check the signal strength indicators on the LCDs of both units to confirm if the distance between the two units exceeds the range of use.
- c. If the problem has not been improved, please contact us to obtain our technical support or replace the faulty unit.
Talk sound is too low
- a. Make sure the volume level of intercom has been set to the maximum.
- b. Try to be close to the position of MIC during talk.
There was a howl or static noise during the call
- a. Maybe the intercoms are too close to each other, please try move away the distance between two intercoms, or move one intercom to another room to eliminate audio self-excitation.
- b. Some electrical equipment will also interfere with the intercom to cause the static noise. E.g. Microwave Oven, Cell phone or other radio devices, please try to adjust the position to move away from these interference sources.
The system is not getting expected transmission range
- a. Ensure that all intercoms are installed away from metal obstacles and other electrical equipment interference.
- b. Please check the signal strength indicators on the LCDs of both intercoms and then try to adjust the placement of the intercom in order to obtain better reception and transmission.
- c. If the problem has not been improved, please contact us to obtain our technical support or replace the faulty unit.
Datganiad Cyngor Sir y Fflint
- Mae'r ddyfais hon yn cydymffurfio â Rhan 15 o Reolau Cyngor Sir y Fflint. Mae gweithredu yn amodol ar y ddau amod canlynol:
- Efallai na fydd y ddyfais hon yn achosi ymyrraeth niweidiol.
- Rhaid i'r ddyfais hon dderbyn unrhyw ymyrraeth a dderbynnir, gan gynnwys ymyrraeth a allai achosi gweithrediad annymunol.
- Gallai newidiadau neu addasiadau nad ydynt wedi'u cymeradwyo'n benodol gan y parti sy'n gyfrifol am gydymffurfio ddirymu awdurdod y defnyddiwr i weithredu'r offer.
NODYN:
Mae'r offer hwn wedi'i brofi a chanfuwyd ei fod yn cydymffurfio â'r terfynau ar gyfer dyfais ddigidol Dosbarth B, yn unol â Rhan 15 o Reolau Cyngor Sir y Fflint.
Mae'r terfynau hyn wedi'u cynllunio i ddarparu amddiffyniad rhesymol rhag ymyrraeth niweidiol mewn gosodiad preswyl.
Mae'r offer hwn yn cynhyrchu defnyddiau a gall belydru ynni amledd radio ac, os na chaiff ei osod a'i ddefnyddio yn unol â'r cyfarwyddiadau, gall achosi ymyrraeth niweidiol i gyfathrebiadau radio. Fodd bynnag, nid oes unrhyw sicrwydd na fydd ymyrraeth yn digwydd mewn gosodiad penodol. Os yw'r offer hwn yn achosi ymyrraeth niweidiol i dderbyniad radio neu deledu, y gellir ei bennu trwy droi'r offer i ffwrdd ac ymlaen, anogir y defnyddiwr i geisio cywiro'r ymyrraeth gan un neu fwy o'r mesurau canlynol:
Ailgyfeirio neu adleoli'r antena sy'n derbyn.
Cynyddu'r gwahaniad rhwng yr offer a'r derbynnydd.
Cysylltwch yr offer ag allfa ar gylched sy'n wahanol i'r un y mae'r derbynnydd wedi'i gysylltu ag ef.
Cysylltwch â'r deliwr neu dechnegydd radio/teledu profiadol am gymorth.
Datganiad Gwybodaeth SAR
Trosglwyddydd radio a derbynnydd yw eich ffôn diwifr. Mae wedi'i ddylunio a'i weithgynhyrchu i beidio â mynd y tu hwnt i'r terfynau allyriadau ar gyfer dod i gysylltiad ag ynni radio-amledd (RF) a osodwyd gan Gomisiwn Cyfathrebu Ffederal Llywodraeth yr UD. Mae'r terfynau hyn yn rhan o ganllawiau cynhwysfawr ac yn sefydlu lefelau a ganiateir o ynni RF ar gyfer y boblogaeth gyffredinol. Mae'r canllawiau'n seiliedig ar safonau a ddatblygwyd gan sefydliadau gwyddonol annibynnol trwy werthusiad cyfnodol a thrylwyr o astudiaethau gwyddonol.
The standards include a substantial safety margin designed to assure the safety of all persons, regardless of age and health. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6 W/kg. * Tests for SAR are conducted with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when tested for use on the body, as described in this user guide, is 0.216W/Kg (Mae mesuriadau a wisgir ar y corff yn amrywio ymhlith modelau ffôn, yn dibynnu ar yr ategolion sydd ar gael a gofynion Cyngor Sir y Fflint). Er y gall fod gwahaniaethau rhwng lefelau SAR ffonau amrywiol ac mewn gwahanol swyddi, maent i gyd yn bodloni gofyniad y llywodraeth am amlygiad diogel. Mae'r Cyngor Sir y Fflint wedi rhoi Awdurdodiad Offer ar gyfer y ffôn model hwn gyda'r holl lefelau SAR a adroddwyd wedi'u gwerthuso yn unol â chanllawiau datguddiad RF Cyngor Sir y Fflint. Mae gwybodaeth SAR ar y ffôn model hwn ymlaen file gyda'r Cyngor Sir y Fflint a gellir dod o hyd iddo o dan adran Grant Arddangos o http://www.fcc.gov/oet/fccid ar ôl chwilio ymlaen
ID Cyngor Sir y Fflint :2BQFX-UT001Additional information on Specific Absorption Rates (SAR) can be found on the Cellular Telecommunications Industry Association (CTIA) web-safle yn http://www.wow-com.com. * Yn yr Unol Daleithiau a Chanada, y terfyn SAR ar gyfer ffonau symudol a ddefnyddir gan y cyhoedd yw 1.6 wat/kg (W/kg) ar gyfartaledd dros un gram o feinwe. Mae'r safon yn ymgorffori ffin diogelwch sylweddol i roi amddiffyniad ychwanegol i'r cyhoedd ac i roi cyfrif am unrhyw amrywiadau mewn mesuriadau.
Gweithrediad a wisgir ar y Corff
Profwyd y ddyfais hon ar gyfer llawdriniaethau arferol a wisgir ar y corff. Er mwyn cydymffurfio â gofynion amlygiad RF, rhaid cadw pellter gwahanu lleiaf o 10mm rhwng corff y defnyddiwr a'r set llaw, gan gynnwys yr antena. Ni ddylai clipiau gwregys trydydd parti, holsters, ac ategolion tebyg a ddefnyddir gan y ddyfais hon gynnwys unrhyw gydrannau metelaidd. Efallai na fydd ategolion a wisgir ar y corff nad ydynt yn bodloni'r gofynion hyn yn cydymffurfio â gofynion amlygiad RF a dylid eu hosgoi. Defnyddiwch yr antena a gyflenwir neu antena gymeradwy yn unig.
Cefnogaeth i Gwsmeriaid
Thank you for purchasing our product. Please read and keep this manual carefully.
Mae croeso i chi gysylltu â ni os oes gennych unrhyw ymholiad.
Post: unitalkstore@outlook.com
Dogfennau / Adnoddau
![]() |
System Intercom Llais Dwy Ffordd Amser Real Digidol Di-wifr UniTalk UT-001 [pdfLlawlyfr Defnyddiwr UT-001F, UT-001P, UT-001 Wireless Digital Full Duplex Real Time Two Way Voice Intercom System, UT-001, Wireless Digital Full Duplex Real Time Two Way Voice Intercom System, Digital Full Duplex Real Time Two Way Voice Intercom System, Full Duplex Real Time Two Way Voice Intercom System, Real Time Two Way Voice Intercom System, Two Way Voice Intercom System, Voice Intercom System, Intercom System, System |
