Synhwyrydd Pridd Dyfnder Aml SENSECAP MTEC-01B

Cyflwyniad Cynnyrch
This Multi-Soil MT-01 Soil Sensor can monitor soil at different depths in real-time. By measuring the dielectric constant of the soil, this Multi-Soil MT-01 sensor can directly and stably reflect the true moisture content of various soils, and is the internationally standard method of measuring soil moisture. Apply to water-saving in farming, checking the weather, monitoring the environment, growing flowers and vegetables in greenhouses, grassy fields, soil testing, plant cultivation, scientific experiments, and more.
Nodweddion:
Soil moisture content, electrical conductivity, and temperature all in one.
Multi-layer monitoring. Supports 4 layers of soil temperature & moisture & EC monitoring.
High-quality plastic shell. Anti-aging and resistant to corrosion from acid and alkali in the soil.
Tight waterproof treatment. It can be immersed in water for a long time without leakage.
Reliable performance. Measurement accuracy is high, less affected by soil salinity, and applicable to various soil types.
Multi-directional imitation misconnection protection. With the power line, ground line, and signal line, there is multi-directional anti-wrong connection protection.
Manyleb
| Tymheredd y Pridd | |
| Amrediad | -30 ~ 70 ℃ |
| Cywirdeb | ±0.5 ℃ |
| Datrysiad | 0.1 ℃ |
| Lleithder y Pridd | |
| Amrediad | 0 ~ 70 % |
| Cywirdeb | ±3 % |
| Datrysiad | 0.1 % |
| Dargludedd Trydanol | |
| Amrediad | 0 ~ 5000 μs/cm Extensible customization range: 0 ~ 20000 μs/cm |
| Cywirdeb | ±10 % |
| Datrysiad | 10 μs / cm |
| Paramedrau Cyffredinol | |
| Rhyngwyneb | RS-485 |
| Protocol | MODBUS-RTU RS485 |
| Pwynt Mesur | 10cm (4 i mewn) 20cm (8 i mewn) 30cm (12 i mewn) 40cm (16 i mewn) |
| Ardal Fesur | Within 10cm outside the surface |
| Amser Ymateb | <100ms |
| Amser Cychwyn | 10 seconds after powering on |
| Cyflenwad Pŵer | 12V ~ 24V |
| Defnydd Presennol | 12V / 40mA 24V / 20mA |
| Tymheredd Gweithredu | -10 ℃ ~ 55 ℃ |
| Graddfa IP | IP68 |
| Hyd Cebl | 10 metr |
| Pwysau Dyfais | 1505g |
Caledwedd drosoddview
Gwifrau

![]() |
Cysylltydd Hedfan | Gwifren Synhwyrydd | Disgrifiad |
| 1 | VCC+ | DC12-24V | |
| 2 | NC | Dim cysylltu | |
| 3 | RS485 A | – | |
| 4 | RS485 B. | – | |
| 5 | GND | Daear |
Dimensiynau

Gosodiad
Set monitoring locations:
Use an earth auger to drill holes at suitable locations, then remove impurities from the removed earth, rub it fine, and add water to make a slurry.

Grouting installation:
Slowly pour the mud into the hole and turn the sensor down slowly in one direction. Until some of the mud is spilled and the 0 scale line is level with the ground surface.

Sylwch: Installation should be done slowly, do not pull the sensor upwards to avoid air entering the hole and affecting the measurement.
Wait for mud to stabilize:
After completing the installation, it is necessary to wait for a period of time til the slurry has stabilised and returned to its normal state before starting monitoring.
Protocol Modbus RS485
Protocol Modbus
Modbus Protocol is widely used to establish master-slave communication between intelligent devices or sensors. A MODBUS message sent from a master to a slave contains the address of the slave, the function code (e.g. ‘read register’ or ‘write register’), the data, and a checksum (LRC or CRC).
Multi-Soil MT-01 sensor with RS485 interface supports Modbus protocol. The communication parameters to factory default values for: Baud rate 9600 bps, one start bit, 8 data bits, no parity, one stop bit.
Communication protocol is Modbus RTU protocol. Communication parameters can be changed by the setup program or MODBUS command, after the communication parameters are changed, the sensor is required to re-enter the sensor to be effective.
Following modbus function code are supported by sensor:
Modbus Function Code 0x03: used for reading holding register.
Modbus Function Code 0x04: used for reading input register.
Modbus Function Code 0x06: used for writing single holding register.
Modbus Function Code 0x10: used for writing multiple
Cofrestrau Modbus
| Enw Paramedr | Cyfeiriad Cofrestru | Math Paramedr | Modbus Function number | Ystod Paramedr a Disgrifiad |
| Soil Temperature (10cm) | 0x0000/0 | INT16, darllenwch | 3/4 | -32768-32767 Divide by 10 to get the true value Unit: ℃ |
| Soil Moisture (10cm) | 0x0001/1 | UINT16, darllen | 3/4 | 0-1000 Correspond to0-100% |
| Soil EC (10cm) | 0x0002/2 | UINT16, darllen | 3/4 | 0-500 Correspond to0-5000μs/cm |
| Pridd Tymheredd (20cm) |
0x0003/3 | INT16, darllenwch | 3/4 | -32768-32767 Divide by 10 to get the true value Unit: C |
| Lleithder y Pridd (20cm) |
0x0004/4 | UINT16, darllen | 3/4 | 0-1000 Correspond to 0-100% |
| Soil EC (20cm) |
0x0005/5 | UINT16, darllen | 3/4 | 0-500 Correspond to 0-5000 μs/cm |
| Pridd Tymheredd (30cm) |
9/9000×0 | INT16, darllenwch | 3/4 | -32768-32767 Divide by 10 to get the true value Unit: “C |
| Soil Moisture (30cm) | 0x0007/7 | UINT16, darllen | 3/4 | 0-1000 Correspond to 0-100% |
| Soil EC (30cm) | 0x0008/8 | UINT16, darllen | 3/4 | 0-500 Correspond to 0-5000 μs/cm |
| Soil Temperature (40cm) | 0x0009/9 | INT16. read | 3/4 | -32768-32767 Divide by 10 to get the true value Unit: ‘C |
| Lleithder y Pridd (40cm) |
0x000A/10 | UINT16, darllen | 3/4 | 0-1000 Correspond to 0-100% |
| Soil EC (40cm) | 0x000B/11 | UINT16, darllen | 3/4 | 0-500 Correspond to 0-5000 μs/cm |
| Slave ADDRESS | 0x0100/256 | UINT16, Read/Write | 3/6/16 | 0-255 Default is 49(Dec) |
Darllen Data Synhwyrydd
Reads data (soil temperature, soil moisture, soil EC) from the sensor (address 49, decimal)
Master Send:
31 03 0000 000C 403F (CRC Checksum)
Sensor Response:
| 31 03 18 | 00D3 (Soil Temperature-10cm) | 0110 (Soil Moisture-10cm) | 0028(Soil |
| EC-10 cm) | 00D0 (Soil Temperature-20cm) | 0121 (Soil Moisture-20cm) | 0032(Soil |
| EC-20 cm) | 00CD (Soil Temperature-30cm) | 012E (Soil Moisture-30cm) | 003C(Soil |
| EC-30 cm) | 00CB (Soil Temperature-40cm) | 0138 (Soil Moisture-40cm) | 0041(Soil |
| EC-40 cm) | 62D9 (CRC Checksum) |
Data representation:
Soil Temperature: INT16 format, divide by 10 to get real value in C
Lleithder y Pridd: UINT16 format, divide by 10 to get real value in %(m³/m³)
Soil EC: UINT16 format, multiply by 10 to get the true value in µs/cm
Am gynample, the data above indicates that:
| 10cm: | Soil Temperature: 21.1℃, | Soil Moisture: 27.2%(m³/m³), Soil | Soil EC: 400 μs/cm; |
| 20cm: | Soil Temperature: 20.8°C | Soil Moisture: 28.9%(m³/m³) | – Soil EC: 500 μs/cm; |
| 30cm: | Soil Temperature: 20.5°C, | Soil Moisture: 30.2% * ((m ^ 3) / (m ^ 3)) | Soil EC: 600 μs/cm; |
| 40cm: | Soil Temperature: 20.3°C, | Soil Moisture: 31.2%(m³/m³), | Soil EC: 650 μs/cm; |
Modify Modbus Address
Set default Modbus address (49 in decimal) to 02:
| Gwiber Caethwas | Cod Swyddogaeth | Register Addr H | Register Addr L | Register Data H | Register Data L | CRC16 H |
CRC16 L |
| 31 | 06 | 01 | 00 | 00 | 02 | 0C | 07 |
Repeat the sent command if the sensor successfully receives and modifies the address.
Sylwch: Make sure that only one slave is connected when using the broadcast address to modify the sensor address.
Fersiwn y Ddogfen
| Fersiwn | Dyddiad | Disgrifiad | Golygydd |
| v1.0 | 1/24/2025 | Argraffiad cyntaf | LeoLiu |
Cefnogaeth i Gwsmeriaid