ERV WALL CONTROLLER
ODD-ERV-AMSERYDD
Llawlyfr Cyfarwyddiadau
Rheolydd Wal ERV-TIMER
RHYBUDD
RHYBUDD - RHAID I'R GOSOD GAEL EI GYNNAL GAN DRYDANYDD CYMWYSEDIG.
Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, unplug the unit or switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Always wear safety glasses and gloves while performing these insteuctions.
RHYBUDD
Gall methu â chydymffurfio â’r canlynol achosi gweithrediad anghyson y rheolydd a/neu’r uned:
- Never install more than three timer devices per ventilation unit. When used in conjunction with screen controller, do not install more than two timer devices
- Cadw rheolaeth yn isel cyftage wiring at least 1 foot (305 mm) away from motors, lighting balast, light dimming circuit and power distribution panel. Do not route control wiring alongside house power wiring Ensure the wires are securely connected
- Defnyddiwch wifren cowper arferol neu gyfaint iseltage wire to connect the unit with the controller, 30M length maximun or use a shielded wire,10M ideal
GOSODIAD
- Tynnwch y plwg o'r uned awyru.
- Cut a 27/8″ X 13/4 ” hole in a wall, at a convenient location for the control. Route a cable (type 22/4) for the control from the unit to this hole. Seefigure at right.
- Rhowch y rheolaeth dros y twll dros dro a marciwch y ddau safle twll sgriw mowntio.
- Remove the control, drillboth screwholes (3/16″ o) in wall and insert the wall anchors (included).
- Stripiwch ddiwedd y cebl i gael mynediad i'r 4 gwifren (tua 3″). Stripiwch ddiwedd pob gwifren (tua 1/4″). Cysylltwch y gwifrau â'r terfynellau waeth beth fo'r lliw gwifren. Sylwch pa liw gwifren sydd wedi'i ddewis ar gyfer pob terfynell.
- Gosodwch y rheolydd i'r wal.
- Perfformiwch y cysylltiad trydanol â chysylltydd terfynell yr uned. Am ragor o fanylion, cyfeiriwch at lawlyfr gosod yr uned awyru.
NODYN: Er mwyn osgoi camweirio, cyfeiriwch at y nodiadau a gymerwyd yng ngham 5 i gydweddu'r lliw gwifren â'r derfynell gywir. - Plygiwch yr uned awyru a phrofwch reolaeth y wal.

SUT I DDEFNYDDIO
Mae'r prif fotwm yn gweithio yn dilyn y dilyniant hwn:
CYFARWYDDIADAU:
- Rheolaeth
Push once for 20-minute, twice for 40-minute, or three times for 60-minute activation. Indicator lights up and the controlled unit goes to high speed.
Push once more to stop activation. Unit returns to its previous setting.
Math o arwydd:
Mae amserydd LED 1 = 20 munud yn weithredol
Mae amserydd LED 2 = 40 munud yn weithredol
Mae amserydd LED 3 = 60 munud yn weithredol
- Data Technegol
Allbwn Voltage = 24V AC 10% or 24V DC 10%
Current Out = 100mA, max
Power Supply = 24V AC :10% or 24V DC±10%
Communication = protocol: Normally opened contact
User Interface = Push Button

www.ortechindustries.ca
1.888.543.6473
13376 Comber Way, Surrey, BC V3W 5V9
205 Heol Summerlea, Bramptunnell, Ontario