masibus 1008S Flow Indicator Totaliser

Cyfansymydd Dangosydd Llif 1008S
| Math Mewnbwn | Amrediad |
| i 20 mA | i 30000 |
| i 20 mA | |
| i 5 V. | |
| i 5 V. | |
| *Pulse Input | |
| Integrated/ Batch Total | i 999999 |
MANYLION
- NIFER Y MEWNBYNIADAU 1 with Optional 2 & 3
- Cywirdeb ± 0.25% of full scale ± 1 Count , **0.45 % – for Integrated/ Batch Total
- BURN OUT DETECTION Available for 1 to 5VDC, 4 to 20 mA, 0 to 10 KHz.
- GWRTHWYNEBIAD MEWNBWN
- 250 Ohms Internal for current Input
- 320K Ohms for Voltage Mewnbwn
- ALLOWABE SIGNAL SOURCE RESISTANCE
- Mewnbwn DC cyftage: 1KΩ or less. Effect from allowable signal source
- Gwrthsafiad: 0.031 % / 100Ω or less
- ALLOWABLE INPUT VOLTAGE
- DC cyftage: ±20V DC
- NOISE REJECTION RATIO
- Modd Cyffredin:> 100db
- Modd arferol:> 40db
- AMSER YMATEB
- Input to relay o/p: < 1 second.
- Input to Analog o/p: < 1 second or less, 63 % (10 – 90%) (Time required for o/p to reach 63% of the maximum excursion when PV changes from 10% to 90%)
- PENDERFYNIAD 16 bit POLARITY
- AMDDIFFYN Heb ei ddarparu
- CEFNDIR COFFA EEPROM
Loop Power Supply Specification
- LOOP POWER SUPPLY 24VDC ± 5% @ 50mA
Allbwn Ail-drosglwyddo
| NIFER O ALLBYNNAU | 1 |
| ARWYDDION ALLBWN | to 20 mA DC
|
| LOAD RESISTANCE | 500Ω neu lai |
| OUTPUT ACCURACY | ± 0.25% of full scale +1 count |
| PENDERFYNIAD | bits (5uA) |
Contact Input (Digital input)
| NO OF INPUTS | 4 |
| DEFNYDD | Input 1 : Stop Batch Input 2 : Integration total zero(Therefore Batch total and roll count will be zero) Input 3 : Start Batch
Input 4 : Batch total zero |
| MATH INPUT | Non- voltage contact input or transistor open collector input |
| INPUT CONTACT CAPACITY | 12VDC,10mA or more (for non – voltage contact input) |
| YMLAEN/ I FFWRDD
PENDERFYNIAD |
• Am non-cyftage mewnbwn cyswllt ON = contact resistance of 1KΩ or
less, OFF = contact resistance of 20KΩ or more • For transistor contact input ON = 2V or less OFF = leak current of 100µA or less |
| LLEIAF
RETENTION TIME FOR STATUS DETECTION |
About 1 Second |
Allbynnau Cyswllt
- NIFER O ALLBYNNAU 4 (2 Flow alarm relays, 2 Batch relays)
- DEFNYDD Flow alarm / Batch relay
- RELAY CONTACT TERMINAL 3(Common, NO, NC)
- RELAY CONTACT RATING 250VAC/5Amps
Manyleb Cyfathrebu
| PROTOCOL | Modbus RTU cyfresol |
| SAFON | EIA RS-485 |
| MAX
CYFATHREBU TRAFOD |
mtrs. (For 9600 bps RS 485) |
| COMMUNICATION METHOD | wire half duplex (RS
485) |
| FFRAM DATA | N, 8, 1 |
| COMMUNICATION RATE | 9600, 19200 bps |
| MAX. CONNECTABLE
CONTROLLERS/ DANGOSYDD |
32 |
| ADDRESS RANGE | i 99 |
Display Unit Specification
| PROCESS VALUE DISPLAY | 0.56” 5 digit 7- segment red display |
| INTEGRATED TOTAL DISPLAY | 0.40” 8 digit 7- segment red display |
| PARAMETER DISPLAY | Same integrated total display |
| STATUS INDICATING LAMP | LEDs coch |
Manyleb Cyflenwad Pŵer
- CYFLENWAD PŴER 110 to 230 VAC, 50Hz ; 24VDC(optional)
- TYWYLLWCH GRYM <10Va
- WITHSTANDING VOLTAGE
- Between primary terminal and secondary terminal : 1500VAC(For 1 min)
- Between primary terminal and ground terminal : 500VDC(for 1 min)
- Between ground terminal and Secondary terminal: 500V AC (for 1 minute).
- (Primary terminal: Power supply, relay output) (Secondary terminal: Analog input/output signal terminals, contact input terminal)
Signal Isolation Specifications
| YNYSU
GWRTHIANT |
Between power supply terminal and ground terminal: 500 VDC, 50MΩ |
| MEASURED INPUT TERMINAL | Isolated from other input/output terminals. Not isolated from 24Vdc supply
(Transmitter power supply) and internal circuit. |
| CYFLENWAD 24V DC
ER MWYN TRAWSNEWID |
Not isolated from the measured input terminal & internal circuit, isolated from other input/output terminals. |
| AIL-DROSGLWYDDO
ALLBWN TERFYNOL |
Isolated from other input/output terminals and internal circuit. |
| CONTACT INPUT TERMINAL | Isolated from other input/output terminals and internal circuit. |
| CYSYLLTIAD CYFNEWID
O/P TERMINAL (DIGITAL INPUT) |
Isolated from other input /output terminals and internal circuit. |
| RS–485
CYFATHREBU TERFYNOL |
Isolated from other input/output terminals and internal circuit. |
| TERFYN CYFLENWAD GRYM | Isolated from other input / output terminals and internal circuit. |
| TERMINAL TIR | Isolated from other input/ output terminals and internal circuit. |
Manyleb Amgylcheddol
- TYMHEREDD GWEITHREDOL 0 i 55°C
- Tymheredd Ystorio 0 i 70°C
- LLITHRWYDD 30 to 90% RH (Noncondensing) WARM UP TIME >10 Minute
- EFFECT OF AMBIENT TEMPERATURE
- Am Voltage Mewnbwn: 0.005% of FS/ °C or less
- For analog output: 0.010% of FS/ °C or less
Alarm Specification
| MATHAU ALARM | Flow high limit, Flow low limit |
| BATCHING ALARM | Pre warn and set point |
| GOSOD
RANGES FOR PROSES GWERTH GALWADAU |
Flow (PV) Alarms:
Min = Zero of individual I/P type Max = Span of individual I/P type |
Manyleb Arddangos
| PV DISPLAY | 5 digit red 7 segment display for flow rate |
| INTEGRATED TOTAL | 8 digit red 7 segment display for integrated total |
| PARAMETER DISPLAY | Same 8 digit red 7 segment display integrated total |
| STATWS
ARDDANGOS |
Red LEDs (for alarm & Batch) |
Manyleb Arall
| ESTYNIAD GWRAIDD SGWÂR | Perthnasol |
| HWYL DIGIDOL | Perthnasol |
| TIME BASE UNIT | Second, minute, hour, day |
| FFACTOR TRAWSNEWID | 0.00 i 99.99 |
| FIVE POINT
LLINELLIAD |
Perthnasol |
| PULSE OUT PUT | Maximum pulse: 20 pulses/Sec.
Cyffro Voltage: <24Vdc with maximum 10 mAdc |
| TORRI LLIF ISEL | Perthnasol |
MANYLION SYMUDOL
- Structure: Front fascia IP54 complied(not certified), Enclosure GP (IP20)
- Body construction: Polycarbonate plastic.
- Case color: Dark grey
- Pwysau: 0.45Kg
- Instrument Dimension: 96 W* 96H*125D max behind panel with terminal (all in mm)
- Mounting Method: Panel mounting
- Panel cut-out: 92W* 92H (all in mm)
- Wiring: 2.5sq.mm
- Standard Accessories: 2 mounting clamp
DISGRIFIAD PANEL BLAEN
| Enw'r Rhan | Swyddogaeth |
SET OR SHIFT |
1. It will allow user to enter in EDIT mode, when instrument is in RUN mode.
2. It will scroll menu and submenu When it is enabled. 3. It will save edited data. |
START OR SHIFT |
1. It will enter into the submenu, when main menu is enabled and shows submenu’s value.
2. It will select the digit to modify, when value is edited. 3. It will start batch, if pressed, when IT & BT are being displayed |
|
CYNYDD |
1. It will increment value of digit selected or constant selected.
2. It will stop batch, if pressed, when BT/IT are being displayed. 3. For Pause batch press stop key for 1 second. 4. If we press stop key for 3 second then batch becomes zero. |
|
|
1. It will escape to previous status, with reference to its current status.
Sequence of status: IT MENU SUB-MENU Parameter’s Value Dilyniant dianc When Esc key is pressed in Menu, the instrument will come in RUN Mode. If user wants to go in EDIT mode, he will have to enter the correct password again. 2. When Esc key is pressed in RUN Mode, it will directly enter in to the set point menu. This function is only applicable when type of instrument is totaliser. |
| RL1, RL2 RL3,RL4 | When Respective Relay LED Lits (In
Red) OR When Channel is OPEN(Channel no. is corresponding to Relay no.) |
| Rx/Tx | When Communication on, two LEDs (In Red) blink. |
BACK PLATE CONNECTION DETAIL
Rear Panel Diagram of 1008S Standard
Rear Panel Diagram Of 1008S With Mass Flow
Terminal Details of 1008S Standard
Terminal Details of 1008S with Mass Flow
Batch total:
This is an eight digit totalized value, displayed as Batch total. As per the selected time base, Zero and Full-scale settings, this total is updated continuously, proportional to input. When New Batch Starts or Integration total is reset this value also gets initialized to 0.
Integration total:
This is an eight digit totalized value, displayed as integrated total. As per the selected time base, Zero and Full-scale settings, this total is updated continuously, proportional to input.
Relay-mode:
In ‘Relay-mode’ (relay nod), if set to ‘normal ‘mode then alarm relays and LEDs will work according to alarm values.
i.e. Relays on, LEDs on
Relays off, LEDs off. But if set to ‘Failsafe’ modede then the alarm relays and LEDs will operate reversibly.
i.e. Relays on, LEDs off Relays off, LEDs on
Cut Off(Low Flow Cut Off):
Cut off could be set to 0000 to 0100. Cut off will display the % value.
Gwerth torbwynt = Cutoff parameter (in %)*Full scale value
If full scale value is 10000 and cut off is 5% Then cut off value will be calculated as = (5/100)*10000 = 500.
So, if the displayed flow rate (displayed at upper window) is less then 500, it will not be added to integration.
For operation manual ymwelwch www.masibus.com
Specifications are subject to change without notice due to continuous improvements.
Pvt Automation Ac Offeryniaeth Masibus. Cyf.
B-30, Ystâd Electroneg GIDC, Sector-25, Gandhinagar382044, Gujarat, India.
Ffon: +91 79 23287275-79
Ffacs: 91 79 + 23287281
Web:www.masibus.com
Ebost:cymorth@masibus.com
Cwestiynau Cyffredin
Q: What are the alarm types supported by by the product?
A: The alarm types supported are Flow high limit and Flow low limit.
Q: What is the power supply specification of the product?
A: The power supply supports 110 to 230 VAC, 50Hz and has a power consumption of…