Cyflwyniad Cynnyrch

  • Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability.
  • Equipped with dual-relay functionality, enabling control of two sets of lighting devices.
  • Supports both mechanical and push switches. Even if the light is manually turned off, remote control via the APP remains available, meeting diverse needs.
  • Supports OTA (Over-the-Air) online upgrades, ensuring timely feature updates and usage safety, keeping the product up-to-date.
  • Supports direct connection to devices via smartphone, allowing direct control through the APP. Supports gateway-free control, enabling LAN remote control, wireless panels, group control, and more. Supports integration with a smart gateway to enable remote control of home devices, making life more convenient.
  • Compact size, allowing easy installation in European, American, and national standard junction boxes, suitable for various installation scenarios.
  • Supports power-off reset functionality and mechanical key reset functionality.

Manylebau Technegol

Model KBS
Math di-wifr Rhwyll SIG Bluetooth 5.2
Newid sianel 2CH
Cyfrol weithredoltage 100-240V~, 50/60Hz,
Max. load current of the relay 10A
Max. load parameters of the relay Resistive load: 1000W@230Vac/CH, 500W@110Vac/CH, Max.2000W Capacitive load: 400W@230Vac/CH, 200W@110Vac/CH, Max.800W
Cerrynt ymchwydd cyfnewid 70A@10ms
Tymheredd gweithio -25 ° C ~ 50 ° C
Maint y cynnyrch L45 × W45.5 × H20.5(mm)
Pwysau cynnyrch 30g
Safonau UL 8750、EN 61347-2-13:2014+A1:2017、EN 61347-1:2015+A1:2021、EN 62493:2015/A1:2022

Delweddau Cynnyrch

LTECH-KBS-Switch-Module (3)

Maint Cynnyrch

LTECH-KBS-Switch-Module (4)

Diagram Gwifrau

  1. Two mechanical switches control one relay each.
  2. One mechanical switch controls two relays.LTECH-KBS-Switch-Module (5)
  3. Two push switches control one relay each.
  4. One push switch controls two relays. LTECH-KBS-Switch-Module (6)

Ceisiadau a Argymhellir

  1. Wireless light control
  2. After setting up the remote control association with the switch module via the APP, both the APP and the remote control can be used to control the device.LTECH-KBS-Switch-Module (7)
  3. Supports local scenes, gateway-free operation, and controllable even when offline.
  4. Work with intelligent gateway, it can realize visual control, cloud scene and automatic linkage. LTECH-KBS-Switch-Module (8)
  5. Intelligent control. Set up more app configs as you like

Cyfarwyddiadau Gweithredu Ap

  1. Cofrestru cyfrif
    Sganiwch y cod QR isod gyda'ch ffôn symudol a dilynwch yr awgrymiadau i gwblhau gosod yr ap. LTECH-KBS-Switch-Module (9)
  2. Gosodiad paramedr
    More settings such as editable binding interface, group control, local scenes, cloud scenes, and automation. LTECH-KBS-Switch-Module (10)
  3. Binding interface settings
    After pairing is completed, enter the binding interface for the smart remote control/smart wireless switch. Select the switch module device to associate it, and then you can control the device’s on/off function using the smart remote control/smart wireless switch. You can also unbind the device from this interface. LTECH-KBS-Switch-Module (11)
  4. Light fixture group
    The same type of lighting fixtures can be grouped together, allowing users to control power on/off and other operations for the entire group, making operations more convenient. Switch to the “Group” menu, click the “+” icon in the upper right corner, follow the prompts to modify the group name, then click “Next,” select the devices you want to include in the group, and save. LTECH-KBS-Switch-Module (12)
  5. Golygfa leol
    Switch to the 【Smart】 page, click “+” in the upper right corner to create a local scene, and after setting the execution action, you can realize the local linkage of Bluetooth devices. LTECH-KBS-Switch-Module (13)
  6. Golygfeydd cwmwl ac awtomeiddio
    Make sure that a smart gateway, such as SP-GW-6S,has been added to the family.
    Cloud scenes: Switch to the 【Smart】 interface and click “+” to create a cloud scene. After setting the execution action, remote linkage can be achieved.
    Automation: Select “Automation” in the【Smart】page and click “+” to create automation. You can choose local/cloud execution mode,and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkage LTECH-KBS-Switch-Module (14)

Ailosod i Ddiffygion Ffatri

  • Mechanical Reset: Connect device to lighting fixture. Hold reset button for 15s until indicator light flashes red rapidly, then release. Press reset button 3 times briefly within 3s. Slow red flash means factory settings restored; rapid blue flash means setup is complete.
  • Power Cycle Reset: With power off, switch device on for 15s then off. Repeat power on/off 6 times (2s on, 5s off each). On 7th power-on, connected fixture blinks 3 times, showing factory settings restored.
  • APP Reset: Click the ” ” on the switch module to enter the main interface, then click the ” ” in the upper right corner to access the settings interface. Click “Delete Device” to complete the reset. LTECH-KBS-Switch-Module (1)

Sylw

  • Product installation and commissioning should be done by a qualified professional. Our company products are and not lightning proof non-waterproof(special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure they are mounted in a water proof enclosure or in an area equipped with lightning protection devices Good heat dissipation will prolong the working life of products. Please ensure good ventilation.
  • Gwiriwch a yw'r cyftage ddefnyddir yn cydymffurfio â gofynion paramedr cynhyrchion.
  • Rhaid i ddiamedr y wifren a ddefnyddir allu llwytho'r gosodiadau golau rydych chi'n eu cysylltu a sicrhau'r gwifrau cadarn.
  • Cyn i chi bweru ar gynhyrchion, gwnewch yn siŵr bod yr holl wifrau'n gywir rhag ofn y bydd cysylltiad anghywir sy'n achosi difrod i osodiadau golau.
  • Os bydd nam yn digwydd, peidiwch â cheisio trwsio cynhyrchion eich hun. Os oes gennych unrhyw gwestiwn, cysylltwch â'ch cyflenwyr.

Cytundeb Gwarant

Cyfnodau gwarant o'r dyddiad cyflwyno: 5 mlynedd.
Darperir gwasanaethau atgyweirio neu amnewid am ddim ar gyfer problemau ansawdd o fewn cyfnodau gwarant.

Gwaharddiadau gwarant isod:
Nid yw'r amodau canlynol o fewn yr ystod gwarant o wasanaethau atgyweirio neu amnewid am ddim:

  • Y tu hwnt i gyfnodau gwarant.
  • Unrhyw ddifrod artiffisial a achosir gan gyfaint ucheltage, gorlwytho, neu weithrediadau amhriodol. Cynhyrchion â difrod corfforol difrifol.
  • Difrod a achosir gan drychinebau naturiol a force majeure.
  • Mae labeli gwarant a chodau bar wedi'u difrodi.
  • No any contract signed by our company.
  1. Repair or replacement provided is the only remedy for customers. Our company is not liable for any incidental or consequential damage unless it is within the law.
  2.  Our company has the right to amend or adjust the terms of this warranty, and release in written form shall prevail.

Mae'r llawlyfr hwn yn destun newidiadau heb rybudd pellach. Mae swyddogaethau cynnyrch yn dibynnu ar y nwyddau. Mae croeso i chi gysylltu â'n dosbarthwyr swyddogol os oes gennych unrhyw gwestiwn.

Dogfennau / Adnoddau

LTECH KBS Switch Module [pdfLlawlyfr Cyfarwyddiadau
KBS Switch Module, KBS, Switch Module, Module

Cyfeiriadau

Gadael sylw

Ni fydd eich cyfeiriad e-bost yn cael ei gyhoeddi. Mae meysydd gofynnol wedi'u marcio *