Gwybodaeth Cynnyrch

Manylebau:

  • Canllaw Creu Protocol Personol
  • Compatible with ENTTEC pixel controllers: DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3
  • Firmware Version Requirements: V1.0 or above for some models, V2.0 or above for others, V4.0 or above for OCTO MK2

Cyfarwyddiadau Defnydd Cynnyrch

Cyflwyniad:
ENTTEC Pixel controllers support over 20 default pixel protocols. The custom protocol feature allows users to create a custom protocol for pixel fixtures not covered by default protocols without the need for new firmware.

Gofynion Gosod:

  • Datasheet of the desired pixel fixture
  • Computer to access the device settings page
  • For ENTTEC Ethernet Controller: Device IP address (DHCP or static)
  • For DIN PIXIE: EMU Software for configuration

Guide to Custom Protocol Creation:

  1. Verify datasheet for compatible pixel protocol
  2. Navigate to the Device’s User Interface to enablethe  custom protocol feature
  3. Adjustthe  pixel fixture’s data voltage timing viathe  web interface based othe n datasheet

Step 1: Verify Datasheet for Compatible Protocol

  1. Check the data transmission method from the datasheet
  2. Identify data transmission method (e.g., D1-D2-D3…Dn or C1-C2-D1-D2…Dn)
  3. Choose a supported protocol with a similar data transmission method

CADARNWEDD CYDNABYDDOL

Mae creu protocol personol i'w weld yn y rheolwyr picsel ENTTEC canlynol:

SKU Cynnyrch Fersiwn Cadarnwedd
73539 DIN PIXIE V2.0 neu'n uwch
70067 MINI PIXELATOR V2.0 neu'n uwch
70068 PIXELATOR MINI MK2 V1.0 neu'n uwch
71521 OCTO MK2 V4.0 neu'n uwch
71522 OCTO MK3 V1.0 neu'n uwch

RHAGARWEINIAD

  • ENTTEC Pixel controllers support more than 20 pixel protocols by default. In the event of missing protocol, this custom feature allows users to create a custom protocol for the desired pixel fixture anytime without having to submit a support request for new firmware.
  • Mae'r nodwedd hon yn galluogi defnyddwyr i addasu'r cyftage amseriad yn seiliedig ar y protocolau a gefnogir os yw'r dull trosglwyddo data yn cyd-fynd ag unrhyw un o'n protocolau a gefnogir.
  • Mae'r ddogfen hon yn darparu cyfarwyddiadau gosod ar gyfer creu protocol picsel wedi'i deilwra a gwirio'r meini prawf.

GOFYNION SEFYDLIAD

Mae angen y canlynol i greu protocol personol:

  1. Taflen ddata: Obtain the datasheet of the desired pixel fixture to gather necessary information. Contact the dealer or manufacturer for this document.
  2. Dyfais: Use a computer to access the device settings page.
  3. For the TEC Ethernet Controller: Obtain the device IP address, which can be either DHCP or static, based on your network settings. Discover the IP using the ENTTEC EMU app.
  4. For DIN PIXIE: Use the EMU Software for configuration.

ARWEINIAD I GREU PROTOCOL CUSTOM

Mae'r nodwedd hon yn caniatáu i ddefnyddwyr addasu'r data cyftage timing to meet specific protocol needs. To create a custom protocol:

  1. Dilyswch y daflen ddata ar gyfer y protocol picsel cydnaws.
  2. Llywiwch i Ryngwyneb Defnyddiwr y Dyfais i alluogi'r nodwedd protocol arferiad.
  3. Addaswch ddata'r gosodiad picsel cyftage amseru drwy'r web rhyngwyneb yn unol â thaflen ddata'r gwneuthurwr.

Cam 1: Gwiriwch y daflen ddata ar gyfer y protocol cydnaws

  1. Gwiriwch ddull trosglwyddo data eich protocol dymunol o'r daflen ddata.
    1. The data transmission method implies how the data is forwarded. Below are demonstrated the common data transmission methods:
      • Mae'r dull mwyaf cyffredin yn trosglwyddo data heb ddarnau ychwanegol (ee, D1-D2-D3…Dn).
        Example: Gwybodaeth a gasglwyd o daflen ddata WB2812B

        ENTTEC-73539-DIN-PIXIE-FIG-2

      • Mae rhai protocolau, fel TM1814, yn cynnwys data ychwanegol ar y blaen (ee, C1-C2-D1-D2…Dn).
        Example: Gwybodaeth a gasglwyd o daflen ddata TM1814

        ENTTEC-73539-DIN-PIXIE-FIG-3

  2. Enwebwch y protocol paru a gefnogir gan y ddyfais (neu dewiswch o'r uchod example) that shares the same data transmission method as your desired pixel protocol.
  3. Ewch ymlaen i Gam 2 am ffurfweddiad pellach.

Step 2: Navigate to the Device’s Settings page to enable the custom protocol feature
In this step, the OCTO/PIXELATOR MINI Series and Din PIXIE are guided accordingly due to their distinct interfaces.
For ENTTEC Ethernet Controllers (OCTO/PIXELATOR MINI Series)

  1. Access to the OCTO/PIXELATOR MINI web rhyngwyneb
    1. Mae Google Chrome yn cael ei awgrymu fel y web browser to access the OCTO/PIXELATOR MINI’s web rhyngwyneb.
    2. Free ENTTEC app, EMU can be used to discover OCTO/PIXELATOR MINI’s IP address. See the ENTTEC webgwefan www.enttec.com i lawrlwytho'r ap.
    3. After entering the IP address of OCTO/PIXELATOR MINI, the user will land on the Home page of OCTO/PIXELATOR MINI’s User Interface.

      ENTTEC-73539-DIN-PIXIE-FIG-4
      Example of the OCTO homepage in Figure 1 indicates IP address 10.10.3.31, which was assigned by the DHCP server. For the out-of-box OCTO/PIXELATOR MINI that is connected directly to a computer (no DHCP server), the default IP address is 192.168.0.10.
      See OCTO/PIXELATOR MINI User Manual ‘Networking’ section for more information.

  2. Navigate to the Settings page – Output Setting.
    Ewch i'r allbwn lle mae'r gosodiad picsel dymunol wedi'i gysylltu ag ef. Dewiswch brotocol picsel o'r gwymplen sy'n rhannu'r un dull trosglwyddo a ddilyswyd yng Ngham 1.

    ENTTEC-73539-DIN-PIXIE-FIG-5

  3. Enable Custom protocol (Continue to Step 3)
    Galluogi'r blwch ticio 'Custom' i gyrchu'r data cyftage setup amseru. Dad-diciwch i analluogi'r protocol personol.

    ENTTEC-73539-DIN-PIXIE-FIG-6

Am DIN PIXIE

  1. Cysylltwch DIN PIXIE â chyfrifiadur gan ddefnyddio USB Math-B.
  2. Lansio Meddalwedd EMU.
  3. Sganiwch am y ddyfais a chliciwch ar Conf y DIN PIXIE a ddarganfuwyd.

    ENTTEC-73539-DIN-PIXIE-FIG-6

  4. Enable Custom Protocol (Continue to Step 3)
    Pick a pixel protocol from the dropdown list that shares the same transmission method verified in tp,1, and enable Custom.

    ENTTEC-73539-DIN-PIXIE-FIG-8

Cam 3: Gosod cyftage amseriad

  1. Cydweddwch y cyftage amseriad ar daflen ddata eich protocol dymunol. Mae Protocol Custom yn gofyn am 4 mewnbwn i gwblhau data cyftage addasiad amseru:
    Cyftage Timing Definition
    Amser Uchel Did 0 (T0H) Mae'r cyftage amser uchel sydd ei angen ar gyfer cod 0.
    Amser Uchel Did 1 (T1H) Mae'r cyftage amser uchel sydd ei angen ar gyfer cod 1.
    Overall Bit Time: Cyfanswm cyftage time for a single bit.

    Lower limit = T0H+T0L

    Upper limit = T1H+T1L

    Ailosod Amser Cyfanswm cyftage amser isel sydd ei angen i ailosod y trosglwyddiad data rhwng pob swp data.

    ENTTEC-73539-DIN-PIXIE-FIG-9

  2. Taflen ddata – Data cyftage gwybodaeth amseru Example
    O daflen ddata WB2818B
    • Locate the ‘Sequence Time’ table in WB2818B’s datasheet for the voltage ystod amseru.
    • Llenwch y cyftage ystod amseru yn y maes arfer yn y Gosodiadau Allbwn.

      ENTTEC-73539-DIN-PIXIE-FIG-10

PWYSIG

  • ENTTEC recommends taking the median value of the range for the start.
  • Bydd yn rhaid i'r defnyddiwr ARBED gosodiadau er mwyn i'r gwerth addasedig ddod i rym.
  • Fine adjustment of value required, followed by actual output test to optimise custom protocol for pixel fixture control.
  • ENTTEC recommends a trial run on the actual setup before finalising the custom protocol setup.
  • Typical issues of incorrect setup include, including and not limited to, failure to light up and output flickering.

CASGLIAD

  • Roedd y canllaw hwn yn dangos sut i sefydlu protocol wedi'i deilwra ar gyfer dyfeisiau ENTTEC cymwys ac yn darparu gwybodaeth dechnegol ar wirio taflen ddata eich gosodiadau picsel dymunol.
  • Trwy ddilyn y camau hyn, gall defnyddwyr greu protocol picsel wedi'i deilwra na cheir yn y gwymplen heb aros am gefnogaeth dechnegol neu ryddhad firmware newydd. Os oes gennych unrhyw gwestiynau neu anhawster dod o hyd i'r wybodaeth gywir, cysylltwch â'n tîm cymorth cyfeillgar yn y swyddfeydd lleol.

FAQ

How do I access the device settings page on my computer?

You can access the device settings page by connecting your computer to the device's network and entering the IP address in a web porwr.

Can I create a custom protocol without the datasheet?

It is recommended to have the datasheet to ensure accurate customization of the protocol based on the pixel fixture's specifications.

Dogfennau / Adnoddau

PDF thumbnail73539 DIN PIXIE
Instruction Manual · DIN PIXIE, PIXELATOR MINI, PIXELATOR MINI MK2, OCTO MK2, OCTO MK3, 73539 DIN PIXIE, 73539, DIN PIXIE, PIXIE

Gofyn Cwestiwn

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Gofyn Cwestiwn

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.