Danfoss-Logo

Danfoss 080Z2830 Gas Detecting Sensor

Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's-PRODUCT

DGS sensors can be used in stand-alone or integrated systems, where continuous real-time, automatic monitoring with Danfoss ADAP-KOOL® Refrigeration Control & Monitoring System and/or Building Management Systems is applied.

DGS supports our customers in complying with environmental F-Gas Regulations and Health & Safety requirements on new or existing systems in:

  •  supermarkets
  •  process refrigeration plants
  •  refrigerated storage and warehousing
  •  special application areas/zones

Typical refrigerant gas applications include:

  • halocarbons: HFCs, HCFCs, CFCs
  • carbon dioxide (CO₂/R744)
  • hydrocarbons (e.g. R290)
  • other special application gases to customer request

Sensing technology varies to make the best detection for a given gas, in terms of performance and cost. DGS-IR is based on infra-red sensor technology, DGS-SC is based on semi-conductor and DGS-PE is based on pellistor.

Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (2)

Manyleb cynnyrch

Data Technegol

Tabl 1: Technical data

Grym cyflenwad 24 V DC ± 20 % ; reverse polarity protected 24 V AC – 10 % / + 15 %
Power Consumption (24 V DC) Max. 250 mA (6 VA)
Allbwn digidol
  • Alarm acknowledge and test alarm: Potential-free contact
  • Alarm relay /fault relay: 40 V AC/DC, 0.5 A, change-over contact (SPDT) Critical relay: normally closed (SIL II compliant), warning relay: normally open
Signal allbwn analog Proportional, overload and short-circuit proof, load ≤ 500 Ohm Measuring range: 0 – 10 V / 2 – 10 V / 0 – 20 mA / 4 – 20 mA
MODBUS Physical 5 V DC, 250 mA max. overload, short-circuit and reverse-polarity protected
Enclosure rate IP 65
Amrediad lleithder 15 – 90 % RH not-condensing
Ymddygiad llosgi UL 94 V2
Lliw tai Du
Dimensiynau (W x H x D mewn mm) 94 x 130 x 57
Gosodiad Mowntio wal
Mynediad cebl 2 x M12 / 3 x M20
Cysylltiad gwifren: Power supply, MODBUS: Screw-type terminals 0.25 – 2.5 mm2 Analogue output, Digital input: Screw-type terminals 0.25 – 1.3 mm2 Sensor head: 3-pin plug connector
Synhwyrydd gwybodaeth DGS-IR (CO2) DGS-SC (HFC) DGS-PE (Propane)
Amrediad tymheredd -35 - 50 ° C -30 - 60 ° C -30 - 60 ° C
Amser ymateb T90 <90 eiliad. ≤ 150 eiliad. <15 eiliad.
Recovery time, T0 90 eiliad. 180 eiliad. 120 eiliad.
Maximum calibration interval 60 mis 12 mis 12 mis
Amrediad mesur 0 – 20000 ppm 0 – 2000 ppm 0 – 5000 ppm
Lowest threshold 10% of the measuring range 10% of the measuring range 10% of the measuring range
Trothwy larwm diofyn 5000 ppm 500 ppm 800 ppm
Cydymffurfiad EN61010-1
B&L – Buzzer and Light (option by product selection) Light (LED): Red / yellow /green (alarm – fault – operation – service) Buzzer: >85 dB (A) (0.1 distance ) 2300 Hz ± 300 Hz

Archebu

Tabl 2: Ordering

Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (3) Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (4)

  • HFC gHFC grrp 1: R1234zp 1: R1234zee, R454C, , R454C, R1234yfR1234yf, R452A, R455A, R454B, R452A, R455A, R454B, R513A, R1233z, R513A, R1233zdd, R515b, R515b
  • HFC gHFC grrp 2: R407Fp 2: R407F, R416A, R417A, R407A, R422A, R427A, R449A, R437A, , R416A, R417A, R407A, R422A, R427A, R449A, R437A, R134AR134A, R438A, R422D, R438A, R422D, R450A, R450A HFC gHFC grrp 3: R448A, R125, R404A, R32, R507A, R434A, R410A, R452Bp 3: R448A, R125, R404A, R32, R507A, R434A, R410A, R452B, , R407CR407C, R143B, R143B

Beiddgar = nwy graddnodi
NODYN: DGS is also available for alternative refrigerant gases on request. Please contact your local Danfoss Sales Office for details.

Ategolion

Hand-held Service tool

Figure 1: Hand-held Service tool

Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (5)

  • Hand-held device for display, calibration, addressing and parameters changes.
  • Communication and power supply will be ensured via a cable that is plugged into the respective devices.

Nodweddion

  • Dyluniad hawdd ei ddefnyddio
  • Simple menu structure
  • Two-line display / 16 characters
  • Six operating buttons
  • Three LEDs for status display
  • Communication / power supply via a cable

Gas detecting sensor, type DGS

Tabl 3: Manylebau

Nodweddion Disgrifiad
Trydanol
Cyflenwad pŵer 5 V DC from device, reverse-polarity protected
Defnydd pŵer 50 mA, max. (0.25 VA)
Serial interface local bus 5 V level / 19200 Baud
Amgylchynol Amodau
Amrediad tymheredd -10 – +40 °C (14 – 104 °F)
Amrediad lleithder 0 – 90% RH nad yw'n cyddwyso
Corfforol
Tai Pholycarbonad
Dimensiynau 117 x 78 x 25 mm
Pwysau Ca. 200g
Dosbarth Gwarchod IP65
Hyd Cebl 1.50 m
Rheoliadau
Cyfarwyddebau EMC directives 2014/30/EU CE Conformity to:EN 61010-1:2010ANSI/UL 61010-1CAN/CS-C22.2 No. 61010-1

Strôb a Chorn

Ffigur 2: Strôb a Chorn

Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (6)

Electronic sounder that allows two levels of alarm (warning, critical) controllable via independent electric contacts.

Nodweddion

  • Tonau detholadwy
  • Separate electric control for strobe and horn

Tabl 4: Manylebau

Larwm Seiniwr Disgrifiad
Cyfrol weithredoltage 12 – 24 V DC
Tymheredd gweithredu -40 - +55 °C
Number of user-selectable tones 32
Lliw lens Coch
Sgôr IP IP 65

Sensor head protection

Ffigur 3: Sensor head protection

Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (7)

  • Plastic protective cap with non-slip, knurled rim, for covering sensors of the DGS series.
  • The elastic protective cap is placed on the sensor to protect it from contamination during installation, cleaning and painting work and to protect the sensor element from poisoning, e.g. by silicone vapours.
  • When commissioning, it is essential to remove the tight-fitting cap to ensure the proper functioning of the sensor.

Nodweddion

  • Hawdd i'w defnyddio
  • Perfect coverage of the sensor head
  • Protection against pollution/poisoning

Tabl 5: Manylebau

CAP Disgrifiad
Deunydd Plastic TPE
Lliw Coch (RAL 3000)
Dimensions inside Ca. 24 mm x 18 mm (D x G ) see figure below
Temperature range cap -50 °C i +120 °C (-58 °F i 248 °F)

Gwarchodwr sblash

Ffigur 4: Gwarchodwr sblash

  • Cap for protecting the DGS sensor against splash water.
  • The cap is placed over the sensor head and secured by means of a detachable zip tie. It protects the sensor against rain and splash water coming from all directions.
  • The splash guard is used in gas warning systems, which are mounted outside unprotected from the weather. It can also be used to protect the sensor during cleaning work.

Nodweddion

  • Protection against rain, splash water and other weather conditions.
  • Easy installation. Assembly and disassembly possible at any time due to detachable zip tie.

Tabl 6: Manylebau

REDCAP Disgrifiad
Deunydd LDPE+PC
Dimensiynau 25 x 37 mm (D x H)
Dosbarth amddiffyn IP66

Set dwythell
The duct mounting set consists of a sampling tube with hose and adapter for DGS sensors. Duct mounting set for sampling from air ducts.

Nodweddion

  • Hawdd i'w defnyddio
  • Perfect coverage of the sensor head
  • Double pipe can be cut to length for adaptation to the duct diameter

Tabl 7: Manylebau

Sampling SET Disgrifiad
Nwy sampling Via sampling tube / connecting hose
Cyfradd llif Min. 5000 m/h (3.1 mph), max. 20,000 m/h (12.4 mph)
Diamedr dwythell aer Min. 0.1 m (3.94 in.), max. 1.0 m (39.37 in.)
Hyd samptiwb ling 250 mm (9.84 in.), adaptable to the duct diameter by cutting to length: 192 mm (7.56 in.), 133 mm (5.24 in.) or 77 mm (3.03 in.)
Hyd pibell 2 x 1000 mm (39.37 in.)
Cynulliad
  • Arrow at the sampling set in flow direction
  • Always install in the center of the duct
  • Keep a minimum distance of at least 1000 mm to duct bends etc.

Addasydd graddnodi

Ffigur 5: Calibration AdapterDanfoss-080Z2830-Gas-Detecting-Sensor-Owner's (9)

  • Calibration adapter for comfortable gas supply to DGS sensors.
  • The calibration adapter is used for the targeted supply of zero and test gases to the sensor head.

Nodweddion:

  • Hawdd i'w defnyddio
  •  Perfect coverage of the sensor head
  • Double pipe can be cut to length for adaptation to the duct diameter

Tabl 8: Manylebau

Eitem Disgrifiad
Cap
Deunydd PE-LD
Dimensions (D x G) 25 x 20 mm (0.98 x 0.79 modfedd)
Hose
Deunydd PVC-P polyvinyl chloride
Amrediad tymheredd -20 – +60 °C (-4 – +140 °F)
Diamedr OD = 7 mm, ID = 4 mm
Hyd 1 m (39.37 mewn)

Pecyn o bell

Figure 6: Remote kitDanfoss-080Z2830-Gas-Detecting-Sensor-Owner's (10)

  • Cable extension with housing for remote mounting of DGS sensors.
  • The remote kit is used as a cable extension for the remote installation of sensors.

Nodweddion

  • Hawdd i'w defnyddio
  • Perfect coverage of the sensor head
  • Double pipe can be cut to length for adaptation to the duct diameter

Tabl 9: Manylebau

Nodweddion Disgrifiad
Corfforol
Deunydd Pholycarbonad
Flammability classification UL 94 V2
Dimensiynau (W x H x D) 94 x 65 x 57 mm
Pwysau 0.2 kg (0.66 pwys)
Dosbarth amddiffyn NEMA 4X (IP65)
Mowntio Mowntio wal
Knockouts for cable entry 2x M25
Rheoliadau
Cyfarwyddebau EMC Directives 2014/30/EU CE, UKCA

Tystysgrifau, datganiadau, a chymeradwyaeth

  • Mae'r rhestr yn cynnwys yr holl dystysgrifau, datganiadau, a chymeradwyaethau ar gyfer y math hwn o gynnyrch. Efallai y bydd gan rif cod unigol rai neu bob un o'r cymeradwyaethau hyn, ac efallai na fydd rhai cymeradwyaethau lleol yn ymddangos ar y rhestr.
  • Some approvals may change over time. You can check the most current status at danfoss.com neu cysylltwch â'ch cynrychiolydd Danfoss lleol os oes gennych unrhyw gwestiynau.

Tabl 10: Tystysgrifau, datganiadau, a chymeradwyaeth

Math o ddogfen Dogfen pwnc Cymmeradwyaeth awdurdod
Datganiad yr UE EMCD/LVD Danfoss

Cefnogaeth ar-lein

Mae Danfoss yn cynnig ystod eang o gefnogaeth ynghyd â'n cynnyrch, gan gynnwys gwybodaeth am gynnyrch digidol, meddalwedd, apiau symudol, ac arweiniad arbenigol. Gweler y posibiliadau isod.

Siop Cynnyrch Danfoss

  • Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (11)Siop Gynhyrchion Danfoss yw eich siop un stop ar gyfer popeth sy'n gysylltiedig â chynnyrch—ni waeth ble rydych chi yn y byd neu ym mha faes o'r diwydiant oeri rydych chi'n gweithio. Cael mynediad cyflym at wybodaeth hanfodol fel manylebau cynnyrch, rhifau cod, dogfennaeth dechnegol, ardystiadau, ategolion, a mwy.
    Start browsing at store.danfoss.com.
  • Dod o hyd i ddogfennaeth dechnegol
    Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (12)Dewch o hyd i'r ddogfennaeth dechnegol sydd ei hangen arnoch i roi'ch prosiect ar waith. Sicrhewch fynediad uniongyrchol i'n casgliad swyddogol o daflenni data, tystysgrifau a datganiadau, llawlyfrau a chanllawiau, modelau a lluniadau 3D, straeon achos, pamffledi, a llawer mwy.
    Dechreuwch chwilio nawr yn www.danfoss.com/cy/service-and-support/documentation.
  • Dysgu Danfoss
    Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (13)Mae Danfoss Learning yn blatfform dysgu ar-lein rhad ac am ddim. Mae'n cynnwys cyrsiau a deunyddiau sydd wedi'u cynllunio'n benodol i helpu peirianwyr, gosodwyr, technegwyr gwasanaeth, a chyfanwerthwyr i ddeall yn well y cynhyrchion, cymwysiadau, pynciau diwydiant, a thueddiadau a fydd yn eich helpu i wneud eich swydd yn well.
    Creu eich cyfrif Danfoss Learning am ddim yn Kwww.danfoss.com/en/service-and-support/learning.
  • Cael gwybodaeth a chefnogaeth leol
    Danfoss-080Z2830-Gas-Detecting-Sensor-Owner's (1)Danfoss lleol webgwefannau yw'r prif ffynonellau ar gyfer cymorth a gwybodaeth am ein cwmni a'n cynhyrchion. Dewch o hyd i argaeledd cynnyrch, cael y newyddion rhanbarthol diweddaraf, neu gysylltu ag arbenigwr cyfagos - i gyd yn eich iaith eich hun.

Dewch o hyd i'ch Danfoss lleol websafle yma: www.danfoss.com/cy/choose-region.

Cwestiynau Cyffredin

What is the maximum calibration interval for the sensor?

The maximum calibration interval is specified by the manufacturer and should be followed to ensure accurate detection.

Can the sensor be used for residential applications?

The sensor is primarily designed for commercial buildings but can be adapted for specific residential use cases based on gas detection requirements.

Dogfennau / Adnoddau

Danfoss 080Z2830 Gas Detecting Sensor [pdfLlawlyfr y Perchennog
080Z2830, 080Z2831, 080Z2832, 080Z2833, 080Z2834, 080Z2835, 080Z2836, 080Z2837, 080Z2838, 080Z2839, 080Z2840, 080Z2841, 080Z2842, 080Z2830 Gas Detecting Sensor, 080Z2830, Gas Detecting Sensor, Detecting Sensor, Sensor

Cyfeiriadau

Gadael sylw

Ni fydd eich cyfeiriad e-bost yn cael ei gyhoeddi. Mae meysydd gofynnol wedi'u marcio *