CISCO Secure Network Analytics Flow Sensor Update Patch

Cyfarwyddyd Cynnyrch
- This document provides the patch description and installation procedure for the Cisco Secure Network Analytics Flow Sensor appliance v7.6.0.
- There are no prerequisites for this patch, but make sure you read the Before You Begin section before you get started.
Enw Patch
- Maint: Fe wnaethom gynyddu maint y clwt SWU files. Mae'r files gall gymryd mwy o amser i lawrlwytho. Hefyd, dilynwch y cyfarwyddiadau yn yr adran Gwiriwch y Gofod Disg sydd ar Gael i gadarnhau bod gennych ddigon o le ar y ddisg gyda'r newydd file meintiau.
Disgrifiad Patch
- This patch, update-fsuf-ROLLUP20260611-7.6.0-v2-01.swu, includes security fixes and fixes for the following issues:
| CDETS | Disgrifiad |
| CSCwu84655 | Missing status indication for diagnostic pack generation |
| CSCwu84453 | Data Store Database Security tab error banner displays placeholder text instead of the user-provided private key size. |
| CSCwu83718 | Missing option in SystemConfig menu to enable or disable IP inbound validation for svc-token-authority |
- Disgrifir atgyweiriadau blaenorol sydd wedi'u cynnwys yn y darn hwn yn Atgyweiriadau Blaenorol.
Details & File Meintiau
| Patch / SWU File Enw | update-fsuf-ROLLUP20260611-7.6.0-v2-01.swu |
|---|---|
| Notes on Patch Size | Patch SWU file sizes were increased; downloads may take longer. Verify disk space using the /lancope/var partition guidance. |
| Security and Issue Fixes Included | CDETS: CSCwu84655, CSCwu84453, CSCwu83718 |
| New Patch File Sizes by Appliance |
|
Cyfarwyddyd Defnydd
Cyn i Chi Ddechrau
- Gwnewch yn siŵr bod gennych ddigon o le ar y Rheolwr ar gyfer yr holl offer SWU files eich bod yn llwytho i fyny i Update Manager. Hefyd, cadarnhewch fod gennych ddigon o le ar gael ar bob teclyn unigol.
Gwiriwch y Lle Disg Sydd Ar Gael
Defnyddiwch y cyfarwyddiadau hyn i gadarnhau bod gennych ddigon o le ar y ddisg:
- Mewngofnodwch i'r rhyngwyneb Gweinyddu Offer.
- Cliciwch Cartref.
- Dewch o hyd i'r adran Defnydd Disg.
- Review y golofn Ar Gael (beit) a chadarnhewch fod gennych y gofod disg gofynnol ar gael ar y rhaniad /lancope/var/.
- Requirement: On each managed appliance, you need at least four times the size of the individual software update file (SWU) ar gael. Ar y Rheolwr, mae angen o leiaf bedair gwaith maint yr holl offer SWU arnoch chi files eich bod yn llwytho i fyny i Update Manager.
- Managed Appliances: For example, os bydd y Casglwr Llif SWU file yw 6 GB, mae angen o leiaf 24 GB ar gael ar y rhaniad Llif Collector (/lancope/var) (1 SWU file x 6 GB x 4 = 24 GB ar gael).
- Manager: For example, os ydych chi'n uwchlwytho pedwar SWU files i'r Rheolwr sydd bob un yn 6 GB, mae angen o leiaf 96 GB ar gael ar y rhaniad /lancope/var (4 SWU filesx 6 GB x 4 = 96 GB ar gael).
Mae'r tabl canlynol yn rhestru'r clwt newydd file maint:
| Offer | Patch File Maint |
| Rheolwr | 6.05 GB |
| Casglwr Llif NetFlow | 3.36 GB |
| sFlow Casglwr Llif | 3.36 GB |
| Cronfa Ddata Casglwr Llif | 2.47 GB |
| Synhwyrydd Llif | 2.09 GB |
| Cyfarwyddwr y CDU | 2.04 GB |
| Storfa Ddata | 2.39 GB |
Llwytho i Lawr a Gosod
Starting with v7.5.1, the following two options are available for downloading software:
- Lawrlwytho Llawlyfr: Download software from Cisco Software Central and upload it to your Update Manager.
- Direct Software Downloads (Beta): Register with your cisco.com user ID (CCOID) and download software directly to your Update Manager.
Lawrlwytho â Llaw
To manually download the patch update file, cwblhewch y camau canlynol:
- Mewngofnodwch i Cisco Software Central, https://software.cisco.com.
- Yn yr ardal Lawrlwytho ac Uwchraddio, dewiswch Mynediad i'w lawrlwytho.
- Teipiwch Ddadansoddeg Rhwydwaith Diogel yn y blwch chwilio Dewis Cynnyrch.
- Dewiswch y model offer o'r gwymplen, yna pwyswch Enter.
- O dan Dewiswch Math o Feddalwedd, dewiswch Clytiau Dadansoddeg Rhwydwaith Diogel.
- Dewiswch 7.6.0 o'r ardal Datganiadau Diweddaraf i leoli'r clwt.
- Lawrlwythwch y diweddariad patch file, update-fsuf-ROLLUP20260611-7.6.0-v2-
- swu, and save it to your preferred location.
Direct Software Downloads (Beta)
To use this Beta integration and download software and patch update files directly to your Update Manager, complete the following steps:
You will need to register with your cisco.com user ID (CCOID) before you can start using Direct Software Downloads. If you have already registered, you can skip to 3. View and Download Updates.
- Open Update Manager
- Mewngofnodwch i'r Rheolwr.
- From the main menu, choose Configure > Global > Central Management.
- Cliciwch ar y tab Rheolwr Diweddaru.
- Register for Direct Software Downloads
If you have already registered, skip to 3. View and Download Updates.
- Click the Direct Software Downloads link to open the registration page.

- Click the Register button to begin the registration process.

- Click the link that is provided.

- You will be taken to the Activate Your Device page. Click Next to continue.
- Mewngofnodwch gyda'ch cisco.com user ID (CCOID).
- You will receive a “Device Activated” message once your activation is complete.

- Go back to the Direct Software Downloads page on your Manager and click Continue.
- Click the links for the EULA and K9 agreements to read and accept the terms. Once the terms are accepted, click Continue.

View and Download Updates
- Click the Check for Updates button to check for any available updates.

- Click the PREVIOUS RELEASES link to view and download previous patches and updates.
- To download an update or patch click the Download All button. Once the download is complete, you will be given the option to return to the Update Manager to continue the update process. Click the Go to Update Manager button to continue the update process.

Gosodiad
I osod y diweddariad patch file, cwblhewch y camau canlynol:
- Mewngofnodwch i'r Rheolwr.
- From the main menu, choose Configure > Global > Central Management.
- Cliciwch ar y tab Rheolwr Diweddaru.
- Ar y dudalen Rheolwr Diweddaru, cliciwch Llwytho i Fyny, ac yna agorwch y diweddariad clwt sydd wedi'i gadw file, update-fsuf-ROLLUP20260611-7.6.0-v2-01.swu.
- Yn y golofn Camau Gweithredu, cliciwch ar yr eicon (Ellipsis) ar gyfer y teclyn, yna dewiswch Gosod Diweddariad.
Mae'r clwt yn ailgychwyn y teclyn.
Atgyweiriadau Blaenorol
Mae'r eitemau canlynol yn atgyweiriadau diffygion blaenorol sydd wedi'u cynnwys yn y darn hwn:
| Cyflwyno 20260512 | |
| CDETS | Disgrifiad |
| The Manager displays the detections pack SWU as an installed version on the Update Manager page after the installation | |
| Cyflwyno 20260512 | |
| CDETS | Disgrifiad |
| CSCwt01559 | SNMPAgentExtractor inserts incorrect values into configuration fields |
| CSCwt38510 | Appliance license status intermittently reverts to Evaluation Mode after a reboot |
| CSCwu50989 | Wrth ailosod y Web Admin user password on non-Manager deletes all other user accounts |
Cysylltu â Chefnogaeth
Os oes angen cymorth technegol arnoch, gwnewch un o'r canlynol:
- Cysylltwch â'ch Partner Cisco lleol
- Cysylltwch â Cisco Support
- I agor achos erbyn web: http://www.cisco.com/c/en/us/support/index.html
- Ar gyfer cefnogaeth ffôn: 1-800-553-2447 (UDA)
- Ar gyfer niferoedd cymorth byd-eang: https://www.cisco.com/c/en/us/support/web/tsd-cisco-worldwide-contacts.html
Gwybodaeth Hawlfraint
- Mae Cisco a logo Cisco yn nodau masnach neu'n nodau masnach cofrestredig Cisco a/neu ei chymdeithion yn yr Unol Daleithiau a gwledydd eraill. I view rhestr o nodau masnach Cisco, ewch i hwn URL: https://www.cisco.com/go/trademarks. Mae'r nodau masnach trydydd parti a grybwyllir yn eiddo i'w perchnogion priodol. Nid yw defnyddio'r gair partner yn awgrymu perthynas bartneriaeth rhwng Cisco ac unrhyw gwmni arall. (1721R)
Datrys problemau
- Patch download/install fails due to insufficient storage: verify available space on the /lancope/var partition as instructed. The requirement is at least bedair gwaith the relevant SWU file size on each managed appliance, and at least bedair gwaith the total SWU sizes uploaded to the Manager.
- Using Direct Software Downloads (Beta) cannot proceed: registration is required with your cisco.com user ID (CCOID). After registration, activate the device as prompted, then return to the Update Manager to continue.
Dogfennau / Adnoddau
![]() | Secure Network Analytics Flow Sensor Update Patch |
Cyfeiriadau
- Ciscobst.cloudapps.cisco.com
- Ciscobst.cloudapps.cisco.com
- Ciscobst.cloudapps.cisco.com
- Ciscobst.cloudapps.cisco.com
- Ciscobst.cloudapps.cisco.com
- Ciscobst.cloudapps.cisco.com
- Ciscobst.cloudapps.cisco.com
- meddalwedd.cisco.commeddalwedd.cisco.com
- software.cisco.com/meddalwedd.cisco.com
- Llawlyfr Defnyddiwrmanual.tools