1. Cynnyrch Drosview

The Bard Urinary Drain Bag is designed for efficient and hygienic collection of urine. This sterile, 4000 mL vinyl bag features an anti-reflux valve to prevent urine backflow, ensuring patient safety and comfort. It includes a double hook hanger and 48-inch tubing for versatile placement and ease of use.

Bard Urinary Drain Bag, 4000 mL capacity, with anti-reflux valve and tubing.

Image 1: Bard Urinary Drain Bag (4000 mL) with tubing and anti-reflux valve.

2. Gwybodaeth Diogelwch

  • For single use only. Discard after use.
  • Do not store in direct sunlight or at extreme temperatures or in high humidity.
  • Do not use if the package is damaged or opened.
  • Consult a healthcare professional for proper usage and disposal instructions.

3. Cynnwys Pecyn

Each pack contains 5 sterile urinary drain bags. Each individual bag includes:

  • 1 x 4000 mL Urinary Drain Bag
  • 1 x 48-inch Drainage Tubing
  • 1 x Anti-Reflux Valve
  • 1 x Double Hook Hanger

4. Cyfarwyddiadau Gosod

  1. Archwiliwch becynnu: Before use, carefully check the sterile packaging. Do not use if the package is opened or damaged.
  2. Paratoi'r bag: Remove the drain bag from its sterile packaging. Ensure the drain valve at the bottom of the bag is in the closed position.
  3. Tiwbiau Cyswllt: Connect the 48-inch drainage tubing securely to the catheter. Ensure a tight fit to prevent leaks.
  4. Attach to Bag: Connect the other end of the drainage tubing to the inlet port of the urinary drain bag. Verify that the connection is secure.
  5. Lleoli'r Bag: Use the double hook hanger to suspend the drain bag below the level of the patient's bladder. This prevents backflow and ensures proper drainage. The hanger can be attached to a bed frame, wheelchair, or other suitable support.

5. Cyfarwyddiadau Gweithredu

  1. Sicrhau Draeniad Priodol: Regularly check that the tubing is not kinked or obstructed, allowing for continuous urine flow into the bag.
  2. Cyfrol Monitro: The bag is graduated with volume markings up to 4000 mL. Monitor the urine volume regularly as instructed by a healthcare professional.
  3. Gwagio'r bag:
    • Place a suitable container below the drain valve.
    • Open the drain valve at the bottom of the bag.
    • Allow the urine to drain completely into the container.
    • Close the drain valve securely after emptying.
    • Dispose of the urine according to medical guidelines.
  4. Anti-Reflux Valve: The integrated anti-reflux valve prevents urine from flowing back up the tubing towards the patient, reducing the risk of infection.

6. Cynnal a Chadw a Glanhau

This urinary drain bag is designed for single use and is sterile. It should not be cleaned or reused. After use, dispose of the bag and tubing according to local medical waste disposal regulations.

7. Datrys Problemau

  • No Urine Flow:
    • Check for kinks or obstructions in the drainage tubing.
    • Ensure the drain bag is positioned below the level of the bladder.
    • Gwiriwch fod pob cysylltiad yn ddiogel.
  • Gollyngiad:
    • Check all connections (catheter to tubing, tubing to bag) for tightness.
    • Ensure the drain valve at the bottom of the bag is fully closed.
    • If the bag itself is damaged, replace it immediately with a new sterile bag.
  • Anesmwythder:
    • Ensure the tubing is not pulling or causing tension.
    • Adjust the position of the bag and tubing for optimal comfort.

If issues persist, consult a healthcare professional.

8. manylebau

Gallu4000 mL
DeunyddFinyl
Hyd Tywio48 modfedd
NodweddionAnti-Reflux Valve, Double Hook Hanger, Graduated Volume Markings
AnffrwythlondebSterile, Single Use
GwneuthurwrBardd

9. Gwarant a Chefnogaeth

For specific warranty information or product support, please refer to the contact details provided on the product packaging or contact Bard customer service directly. As a medical device, proper handling and usage are crucial for its intended function.

Dogfennau Cysylltiedig - B0FG5THNF3

Cynview Bard CB5002 Canllaw Gosod Bwrdd Cyfathrebu
Cyfarwyddiadau gosod atodol ar gyfer Bwrdd Cyfathrebu Bard CB5002, sy'n cwmpasu gosod, gwifrau, a gweithdrefnau mewngofnodi diofyn ar gyfer systemau HVAC.
Cynview Cyfarwyddiadau Gosod Awyrydd Ystafell Fasnachol Bard CRV-V5A
This document provides detailed installation instructions for the Bard CRV-V5A Full Flow Modulating Low Leakage Commercial Room Ventilator. It covers general information, unpacking, kit components, basic installation procedures, control system notes, blade adjustment, and operational sequences for compatibility with Bard Wall Mount Air Conditioner and Heat Pump models.
Cynview Cyflyrwyr Aer Bard THE WALL-MOUNT™: Manylebau a Nodweddion
Darganfyddwch gyfres Bard THE WALL-MOUNT™ o gyflyrwyr aer wal, sy'n cynnig atebion oeri sy'n effeithlon o ran ynni ar gyfer cymwysiadau masnachol. Mae'r ddogfen hon yn manylu ar fodelau W17A i W60A, oerydd R-410A, nodweddion wedi'u peiriannu, a manylebau.
Cynview Cyfarwyddiadau Gosod Cyflyrydd Aer Wal Bard MULTI-TEC W42-72AC a Rheolydd Goruchwyliol LC6000-200
Canllaw gosod cynhwysfawr ar gyfer y Cyflyrydd Aer Wal-Mount Bard MULTI-TEC W42-72AC a'r Rheolwr Goruchwylio LC6000-200. Yn cwmpasu paratoi'r safle, gosod yr uned, gwifrau, gosod y system, ffurfweddu synwyryddion, a gweithdrefnau gweithredol.
Cynview Llawlyfr Rhannau Amnewid Cyflyrydd Aer Pecynedig wedi'i osod ar y wal Bard W12AF-A W12AF-K
Llawlyfr rhannau newydd cynhwysfawr ar gyfer modelau W12AF-A a W12AF-K Cyflyrydd Aer Pecynedig wedi'i osod ar y wal Bard, yn manylu ar gydrannau'r cabinet, cydrannau swyddogaethol, panel rheoli, a chynulliad chwythwr gyda rhifau rhannau a diagramau.
Cynview Llawlyfr Gosod a Gweithredu Arddangosfa Gyffwrdd Bard 8620-308 PGDx
Mae'r llawlyfr hwn yn darparu cyfarwyddiadau cynhwysfawr ar gyfer gosod, gweithredu a ffurfweddu'r Arddangosfa Gyffwrdd Bard 8620-308 PGDx ar gyfer Unedau MEGA-TEC Annibynnol. Mae'n cwmpasu gwybodaeth gyffredinol, gweithdrefnau gosod, llywio rhyngwyneb, gosodiadau system a datrys problemau.