TRACEABLE AO-94460-72

Traceable® Digital Thermometer with Calibration (Bottle Probe)

Model: AO-94460-72 | Brand: TRACEABLE

Rhagymadrodd

This manual provides detailed instructions for the proper use, setup, and maintenance of your Traceable® Digital Thermometer with Bottle Probe. This precision instrument is designed for accurate temperature monitoring, particularly in environments requiring stable temperature readings such as refrigerators, freezers, and water baths. It features a sealed bottle probe that mimics the temperature of stored liquids, preventing false alarms from temporary door openings.

Each unit comes with a NIST-traceable certificate from an ISO/IEC 17025:2017 (1750.01) accredited calibration laboratory, ensuring accuracy and reliability.

Cynnyrch Drosview

Traceable Digital Thermometer with Bottle Probe

Ffigur 1: Blaen view of the Traceable Digital Thermometer with Bottle Probe. The display shows current, minimum, and maximum temperatures. The bottle probe is connected via a cable.

Traceable Digital Thermometer in a refrigerator setting

Figure 2: The Traceable Digital Thermometer with its bottle probe positioned inside a refrigerator, demonstrating its typical application for stable temperature monitoring.

The Traceable Digital Thermometer is equipped with a triple-display, allowing simultaneous viewing of the current, minimum, and maximum temperatures. The sealed bottle probe is filled with a non-toxic glycol solution, which buffers temperature changes, providing a more accurate representation of the temperature of stored contents rather than ambient air fluctuations.

Gosod a Gosod

  1. Gosod Batri: The thermometer requires one AA battery (included). Open the battery compartment on the back of the unit and insert the battery, observing polarity.
  2. Lleoliad Archwilio:
    • Place the bottle probe inside the environment you wish to monitor (e.g., refrigerator, freezer). Ensure the probe is positioned where it will accurately reflect the temperature of the contents.
    • Route the probe cable carefully to avoid pinching or damage.
  3. Lleoliad Uned:
    • Use the fold-out stand to place the unit on a flat surface.
    • Utilize the magnetic strips on the back to attach the unit to a metal surface (e.g., refrigerator door).
    • Hang the unit on a wall using the keyhole slot.
  4. Pŵer Cychwynnol Ar: The unit should power on automatically once the battery is installed. The display will show the current temperature, along with the minimum and maximum recorded temperatures since the last reset.
Yn ol view of Traceable Digital Thermometer showing battery compartment and stand

Ffigur 3: Cefn view of the thermometer, illustrating the battery compartment, fold-out stand, and wall-mount keyhole.

Cyfarwyddiadau Gweithredu

Swyddogaethau Arddangos

The thermometer's display shows three temperature readings simultaneously:

Swyddogaethau Botwm

BotwmSwyddogaeth
COF YN GLIRPress to clear the stored MIN and MAX temperature readings. The display will update with the current temperature as the new MIN/MAX.
MODDToggles between Celsius (°C) and Fahrenheit (°F) temperature units.
ALARM ON / OFF SwitchActivates or deactivates the audible alarm function. When activated, the alarm will sound if the temperature goes outside the set high/low alarm limits.
RESET (on back)A small button on the back of the unit (often recessed) used to perform a hard reset of the device, typically requiring a pointed object like a paperclip. This will clear all settings and memory.
LO/HI (on back)Buttons on the back of the unit used to set the low and high temperature alarm limits. Refer to the alarm setting section for details.

Setting Alarms (Optional)

The thermometer can be configured to sound an alarm if the temperature exceeds or falls below user-defined limits. The alarm setting buttons (LO and HI) are located on the back of the unit.

  1. Ensure the ALARM ON/OFF switch is in the OFF position before setting limits.
  2. Pwyswch a dal y LO button on the back of the unit. The LO temperature will flash. Use the MODD button on the front to adjust the desired low alarm limit. Release the LO button to set.
  3. Pwyswch a dal y HI button on the back of the unit. The HI temperature will flash. Use the MODD button on the front to adjust the desired high alarm limit. Release the HI button to set.
  4. Once limits are set, slide the ALARM ON / OFF switch to the ON position to activate the alarm.
  5. If the temperature goes outside the set range, the alarm will sound. To silence the alarm, slide the ALARM ON/OFF switch to OFF.
Close-up of thermometer buttons and back panel with alarm settings

Ffigur 4: Manwl view of the thermometer's front control buttons (Memory Clear, Mode, Alarm On/Off) and the rear panel showing the LO, HI, and Reset buttons for alarm configuration.

Manylebau

NodweddManylyn
Rhif ModelAO-94460-72
Amrediad Tymheredd-50 i 70°C (-58 i 158°F)
Datrysiad1° (Celsius/Fahrenheit)
Math ArddangosDigital LCD, Triple-display
Math o BrawfSealed Bottle Probe (glycol-filled)
Hyd y Cebl ProbTua 3 metr (10 troedfedd)
Ffynhonnell Pwer1 x Batri AA (wedi'i gynnwys)
Dimensiynau Cynnyrch8.19 x 4.61 x 2.44 inches (20.8 x 11.7 x 6.2 cm); 8 ounces
Deunydd AllanolPlastig
Nodwedd ArbennigHigh Accuracy, NIST-Traceable Calibration
Cydrannau wedi'u CynnwysDigital Thermometer Unit, Bottle Probe, 1 AA Battery, NIST-Traceable Certificate
Dimensions of the Traceable Digital Thermometer

Figure 5: Diagram showing the approximate dimensions of the thermometer unit.

Cynnal a Chadw a Gofal

Datrys problemau

ProblemAchos PosiblAteb
Dim arddangosfa neu arddangosfa dywyllDead or low battery; incorrect battery installation.Amnewidiwch y batri AA, gan sicrhau'r polaredd cywir (+/-).
Darlleniadau anghywirProbe not properly placed; probe damage; unit malfunction.Ensure the bottle probe is fully immersed in the monitored environment. Check the probe cable for visible damage. If issues persist, contact customer support.
Larwm ddim yn seinioAlarm switch is OFF; alarm limits not set correctly.Slide the ALARM ON/OFF switch to ON. Verify that the LO and HI alarm limits are set to the desired range.
MIN/MAX readings not clearingMEMORY CLEAR button not pressed firmly or unit malfunction.Press the MEMORY CLEAR button firmly. If it still doesn't clear, try a hard reset using the RESET button on the back.

Gwarant a Chefnogaeth

Traceable products are designed for reliability and accuracy. For warranty information or technical support, please refer to the official TRACEABLE website or contact your authorized distributor. Each product includes a NIST-traceable certificate, ensuring its accuracy at the time of purchase.

Am gymorth pellach, gallwch ymweld â'r TRACEABLE Store on Amazon neu'r gwneuthurwr websafle.

Dogfennau Cysylltiedig - AO-94460-72

Cynview Thermomedr Oergell Signal Radio Olrhainadwy 37804-10: Llawlyfr Defnyddiwr a Chyfarwyddiadau
Llawlyfr defnyddiwr swyddogol a chyfarwyddiadau ar gyfer Thermomedr Oergell Signal Radio Traceable 37804-10. Dysgwch am fanylebau, gosodiad, gweithrediad, datrys problemau, a nodweddion ar gyfer monitro tymheredd yn gywir.
Cynview Traceable Extra-Long Probe Waterproof Thermometer Instructions and Specifications
User manual and specifications for the Traceable Extra-Long Probe Waterproof Thermometer (Cat. No. 6406), including operation, probe use, display messages, troubleshooting, and warranty information.
Cynview TraceableLIVE WiFi Datalogging Refrigerator/Freezer Thermometer Instructions
Comprehensive instructions for setting up and operating the TraceableLIVE WiFi Datalogging Refrigerator/Freezer Thermometer, covering controls, specifications, setup, WiFi configuration, alarms, and troubleshooting.
Cynview Traceable Kangaroo Thermometer Instructions and Specifications
User manual and specifications for the Traceable Kangaroo Thermometer, detailing operation, features like temperature alarms and memory, probe cable management, bench stand usage, battery replacement, and warranty information.
Cynview Traceable Refrigerator/Freezer Digital Thermometer Quick-Start Guide
Quick-start guide for the Traceable Refrigerator/Freezer Digital Thermometer (Models 5650, 5651, 5652). Learn setup, configuration, and alarm functions for accurate temperature monitoring.
Cynview Traceable Refrigerator/Freezer Digital Thermometer Quick-Start Guide
Quick-start guide for the Traceable Refrigerator/Freezer Digital Thermometer (Models 5650, 5651, 5652). Learn how to set up, configure alarms, and understand display messages for accurate temperature monitoring.