1. Rhagymadrodd
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Daikin 18,000 BTU 2-Zone Mini Split Air Conditioner Heat Pump R-32 System. Please read this manual thoroughly before using your new air conditioning unit and retain it for future reference.

Figure 1: Complete Daikin 2-Zone Mini Split System with outdoor condenser, two indoor units, and installation accessories.
2. Gwybodaeth Bwysig am Ddiogelwch
WARNING: Installation and servicing of this equipment must be performed by qualified, experienced technicians. Improper installation or servicing can result in property damage, personal injury, or death. This system uses R-32 refrigerant, which requires specific handling procedures. Always consult local codes and regulations.
- Gwnewch yn siŵr bod y cyflenwad pŵer wedi'i ddatgysylltu cyn unrhyw osod neu gynnal a chadw.
- Gwisgwch offer amddiffynnol personol (PPE) priodol yn ystod gosod a chynnal a chadw.
- Peidiwch â cheisio atgyweirio neu addasu'r uned eich hun. Cysylltwch â thechnegydd gwasanaeth cymwys.
- Cadwch blant ac anifeiliaid anwes i ffwrdd o'r uned awyr agored yn ystod y gweithrediad.
3. Cynnwys Pecyn
Gwiriwch fod yr holl gydrannau yn bresennol ac yn ddi-ddifrod wrth eu derbyn:
- 1x 2MXM-A Series Multi-Split 18,000 BTU Heat Pump Air Conditioner Outdoor Condenser
- 1x Maxwell Wall Mounting Bracket (for outdoor unit)
- 2x FTXV Series Indoor Fan Coils with Remote Control
- 2x Maxwell 15 ft Pre-Flared Installation Kits with Interconnecting Cables (for each indoor unit)
4. Manylebau Technegol

Figure 2: System dimensions and key specifications for the Daikin 2-Zone Mini Split.
| Nodwedd | Manyleb |
|---|---|
| Brand | DAIKIN |
| Gwybodaeth Model | 2MXM18AVJU9 + FTXV12AVJU9 + FTXV12AVJU9 |
| Effeithlonrwydd (SEER2) | 21 |
| Gallu | 1.5 Tunnell (18,000 BTU) |
| Lefel Sŵn | 24 Desibel (Dan Do) |
| Oergell | R-32 |
| Gallu Oeri | 17,200 BTU (5,700 BTU Min – 21,000 BTU Max) |
| Cynhwysedd Gwresogi | 18,500 BTU (2,900 BTU Min – 25,000 BTU Max) |
| Operating Cooling Range | 14°F i 115°F |
| Operating Heating Range | 5°F i 59.9°F |
| Cyflenwad Pŵer | 1Ph, 60 Hz, 208-230V |
| Ardystiedig AHRI | #214837757 |
| Nodweddion Arbennig | Inverter Compressor, Multi-Zone Comfort, Automatic Defrosting, Silent Mode, 4 Way Swing, Titanium Photocatalytic Air Purifying Filter, Econo Mode, Remote Controlled, Wireless LAN connection, Self-diagnosis |
5. Canllaw Gosod
Installation of this Daikin Mini Split system requires specialized knowledge and tools. It is strongly recommended that installation be performed by an HVAC-certified technician to ensure proper function, safety, and warranty validity.
5.1 Camau Gosod Cyffredinol (Argymhellir Gosod Proffesiynol)
The following video provides a general overview of mini-split installation steps. Please note that specific details may vary for your Daikin model. Always refer to the detailed instructions provided in your physical owner's manual and consult with a certified installer.
Video 1: General Mini Split Installation Guide. This video demonstrates common steps for installing a mini split unit. Specific procedures for your Daikin model may differ. Professional installation is highly recommended.
5.2 Cydrannau Gosod Allweddol
- Mowntio Uned Dan Do: Securely attach the indoor unit mounting plate to the wall using appropriate fasteners. Ensure it is level.
- Lleoliad Uned Awyr Agored: Position the outdoor condenser on a stable, level surface or a dedicated wall mounting bracket. Ensure adequate clearance for airflow.
- Cysylltiad Set Llinell: Connect the pre-flared copper line sets between the indoor and outdoor units. Ensure all connections are tight and leak-free.
- Gwifrau Trydanol: Connect the electrical wiring according to the wiring diagram in your manual. This typically involves connecting power, ground, and communication wires.
- Hwfro'r Set Llinell: A vacuum pump must be used to remove all air and moisture from the refrigerant lines before releasing refrigerant. This is a critical step for system performance and longevity.
- Rhyddhau Oergell: Carefully open the service valves on the outdoor unit to release the R-32 refrigerant into the system.

Figure 3: The Daikin outdoor condenser unit features Blue Fin anti-corrosion treatment on the heat exchanger for enhanced durability.
6. Cyfarwyddiadau Gweithredu
Your Daikin Mini Split system offers versatile control options for personalized comfort.
6.1 Swyddogaethau Rheoli o Bell
Each indoor unit comes with a dedicated remote control. The remote allows you to:
- Trowch yr uned ymlaen / ODDI
- Addasu gosodiadau tymheredd
- Select operating modes (Auto, Cool, Dry, Heat, Fan Only)
- Addasu cyflymder y gefnogwr
- Control airflow direction (Swing)
- Set timers for automatic operation
- Activate special features like ECONO mode, Powerful mode, and Sleep mode
Video 2: Demonstrating the remote control and indoor unit operation. This video shows how to use the remote control to adjust settings and highlights the quiet operation of the indoor unit.
6.2 Daikin One Home App & Voice Control
The system works exclusively with the Daikin One Home app, allowing for convenient remote control and monitoring. It also supports voice commands with Alexa and Google Home for effortless environment control.
- Download the Daikin One Home app from your device's app store.
- Follow the in-app instructions to connect your mini split system.
- Integrate with Alexa or Google Home through their respective apps for voice control.

Figure 4: Diagram of the FTXV Series indoor unit, highlighting key components and features such as washable air filters and Titanium Apatite Deodorizing Filters.
7. cynnal
Mae cynnal a chadw rheolaidd yn sicrhau perfformiad a hirhoedledd gorau posibl eich system Daikin Mini Split.
7.1 Glanhau'r Hidlydd Aer
The indoor units are equipped with 2-Washable Air Filters and 2-Titanium Apatite Deodorizing Filters. Clean these filters regularly (e.g., every 2 weeks or as needed) to maintain air quality and system efficiency.
- Diffoddwch yr uned a datgysylltwch y pŵer.
- Agorwch banel blaen yr uned dan do.
- Tynnwch yr hidlyddion aer.
- Clean the washable filters with a vacuum cleaner or wash them with water and a mild detergent. Allow them to dry completely before reinstallation.
- The Titanium Apatite Deodorizing Filters should be cleaned by vacuuming. Do not wash these filters with water.
- Ail-osodwch y hidlwyr a chau'r panel blaen.
7.2 Cynnal a Chadw Uned Awyr Agored
Keep the area around the outdoor unit clear of debris, leaves, and other obstructions to ensure proper airflow. Periodically clean the outdoor coil with a soft brush or vacuum cleaner. Ensure the drain pan and drain line are clear.
8. Datrys Problemau
If you encounter issues with your Daikin Mini Split system, refer to the following common troubleshooting tips. For complex problems, contact a certified HVAC technician.
- Uned Ddim yn Troi Ymlaen: Gwiriwch y cyflenwad pŵer, y torrwr cylched, a sicrhewch fod batris y teclyn rheoli o bell yn gweithio'n iawn.
- Oeri/Gwresogi Annigonol: Verify temperature settings, ensure air filters are clean, check for obstructions around indoor/outdoor units, and confirm all windows/doors are closed.
- Sŵn Anarferol: Mae synau bach yn ystod y llawdriniaeth yn normal. Os bydd synau uchel neu anarferol yn digwydd, cysylltwch â thechnegydd.
- Dŵr yn gollwng: Check the indoor unit's drain line for blockages. Ensure the outdoor unit is level.
- Codau Gwall: If an error code appears on the display, consult your detailed owner's manual for specific code meanings and recommended actions.
9. Gwarant a Chefnogaeth
Your Daikin Mini Split system comes with a Gwarant Gwneuthurwr 12 Flwyddyn. To ensure warranty validity, the system must be installed by an HVAC-certified technician.
For warranty claims, technical support, or service inquiries, please refer to the contact information provided in your official warranty documentation or visit the Daikin websafle.