Trydan Globe 17000207

Globe Electric 17000207 Triple Head Motion Activated LED Flood Light Security Light User Manual

Model: 17000207

1. Gwybodaeth Diogelwch

Please read and understand this entire manual before attempting to assemble, operate, or install the product. Failure to do so could lead to electric shock, fire, or other injuries that could be fatal or cause serious damage.

2. Cynnwys Pecyn

Gwiriwch fod yr holl gydrannau yn bresennol cyn dechrau'r gosodiad.

3. manylebau

ManylebGwerth
Rhif Model17000207
Ffynhonnell PwerGwifrau caled
Wattage32 Wat
Disgleirdeb3200 o Lumens
Tymheredd Lliw4000 Kelvin (Gwyn golau dydd)
Parth Canfod Cynnig240 degrees, up to 50 ft (15 m)
DeunyddPlastig
Defnydd Dan Do / Awyr AgoredAwyr Agored
Lefel Gwrthsefyll DŵrGwrth-ddŵr
Dimensiynau (L x W x H)7" x 12" x 8.4"
GwarantGwarant gyfyngedig gwneuthurwr 2 flwyddyn
Dimensions of the Globe Electric 17000207 flood light, showing 12 inches width, 8.4 inches height, and 7 inches depth.

Image: Product dimensions for planning installation space.

4. Gosod a Gosod

This flood light is hardwired and requires connection to your home's electrical system. If you are not comfortable with electrical wiring, it is recommended to consult a qualified electrician.

4.1 Opsiynau Mowntio

The fixture offers dual mounting capabilities, allowing for installation on a wall or under an eave. The canopy can be rotated to accommodate the desired position.

Diagram showing the flood light installed as a wall mount and an eave mount, with an arrow indicating rotation of the canopy for different orientations.

Image: Wall mount and eave mount installation options.

4.2 Camau Gosod

  1. Trowch Pŵer i ffwrdd: Before starting, ensure the power to the installation area is turned off at the circuit breaker or fuse box.
  2. Install Mounting Bar: Secure the mounting bar onto the junction box.
  3. Gosod Plât Mowntio: Attach the mounting plate to the mounting bar.
  4. Cysylltiadau Gwifren: Connect the fixture's wires to your home's electrical wires according to local codes (typically black to black, white to white, and ground to ground). Use wire nuts to secure connections.
  5. Atodwch gêm: Secure the flood light fixture to the mounting plate using the center bolt.
  6. Sêl: Apply weather-resistant sealant around the mounting plate to prevent water intrusion.
  7. Adfer Pwer: Once installation is complete and secure, restore power to the circuit.
Three step diagram showing installation: 1. Install mounting bar onto junction box. 2. Install mounting plate to the mounting bar. 3. Attach fixture to mounting plate with center bolt.

Image: Step-by-step installation guide.

5. Cyfarwyddiadau Gweithredu

The Globe Electric 17000207 flood light features motion activation and adjustable settings for optimal performance.

5.1 Motion Activation

The integrated motion sensor detects movement within a 240-degree zone, up to 50 feet (15 meters) away. The light will activate when motion is detected within this range.

Diagram illustrating a person walking within a 240-degree, 50-foot detection zone of the motion-activated flood light.

Image: Motion detection zone illustration.

5.2 MotionBright™ 2-Level Lighting

This feature provides constant low ambient lighting when no motion is detected, and automatically switches to full brightness when motion is sensed, enhancing security and saving energy.

Side-by-side comparison showing the flood light providing low ambient light when no motion is detected, and full brightness when motion is detected.

Image: MotionBright feature demonstrating low and full brightness modes.

5.3 Addasu Gosodiadau

The motion sensor unit has adjustable dials to customize the light's behavior:

Close-up image of the flood light's control panel, showing dials for On Time, Sensitivity, Brightness, and MotionBright settings, with labels for each function.

Image: Control dials for adjusting light settings.

5.4 Addasu Lamp Penaethiaid

Y tri LED lamp heads are independently adjustable, allowing you to direct the light precisely where needed for optimal coverage.

Diagram showing the adjustable lamp heads of the flood light, with arrows indicating their range of motion.

Image: Adjustable lamp heads for directing light.

6. cynnal

This LED flood light is designed for minimal maintenance.

7. Datrys Problemau

If you experience issues with your flood light, refer to the following common problems and solutions:

ProblemAchos PosiblAteb
Nid yw golau yn troi ymlaen.No power, faulty wiring, sensor blocked, incorrect settings.Check circuit breaker. Verify wiring connections. Clear sensor lens. Adjust 'On Time' or 'Sens' settings.
Mae golau yn aros ymlaen yn barhaus.Continuous motion detected, 'On Time' set too long, 'MotionBright' setting.Ensure no constant motion in detection zone. Adjust 'On Time' to a shorter duration. Check 'MotionBright' setting (e.g., if set to 'Dusk to Dawn').
Motion not detected reliably.Sensor blocked, sensitivity too low, incorrect angle.Clear sensor lens. Increase 'Sens' setting. Adjust sensor angle for optimal coverage.
Fflachiadau golau.Loose wiring connection, power fluctuations.Check all wiring connections for tightness. Consult an electrician if power fluctuations are suspected.

8. Gwarant a Chefnogaeth

This Globe Electric product is backed by a Gwarant gyfyngedig gwneuthurwr 2 flwyddyn o'r dyddiad prynu. Mae'r warant hon yn cwmpasu diffygion mewn deunyddiau a chrefftwaith o dan ddefnydd arferol.

For warranty claims, technical assistance, or further inquiries, please contact Globe Electric customer support. Keep your proof of purchase for warranty validation.

Am ragor o wybodaeth, ewch i'r Globe Electric Store on Amazon.

Dogfennau Cysylltiedig - 17000207

Cynview Globe Electric Motion Activated Security Light: Installation and Operation Manual
This guide provides detailed instructions for installing, operating, and troubleshooting the Globe Electric motion-activated security light (Model 17000200). Includes specifications, safety warnings, and maintenance tips.
Cynview Canllaw Gosod Glanfa LED 3 Golau Globe Electric ROCKHILL gyda Golau Nos wedi'u Gyrru gan Symudiad
Canllaw gosod manwl a llawlyfr defnyddiwr ar gyfer y Globe Electric ROCKHILL Vanity LED 3-Golau gyda Golau Nos wedi'i Actifadu gan Symudiad (Model 63000230), gan gynnwys cyfarwyddiadau diogelwch, nodweddion, manylebau, camau gosod, a datrys problemau.
Cynview Golau Diogelwch Pensaernïol LED wedi'i Actifadu gan Symudiad Trydan Globe - Canllaw Gosod a Gweithredu
Mae'r canllaw hwn yn darparu cyfarwyddiadau manwl ar gyfer gosod, gweithredu a datrys problemau gyda'r Globe Electric Motion Activated LED Architectural Security Light. Dysgwch am fanylebau, rhagofalon diogelwch, gosodiad a phroblemau cyffredin.
Cynview Golau Gwagedd LED 1-Golau Globe Rockhill gyda Golau Nos wedi'i Actifadu gan Symudiad - Canllaw Gosod
Canllaw gosod a defnyddiwr ar gyfer Golau Gwagedd LED 1-Golau Globe Rockhill (model 63000231). Mae'r nodweddion yn cynnwys goleuadau LED, golau nos sy'n cael ei actifadu gan symudiad, a thymheredd lliw addasadwy. Yn cynnwys cyfarwyddiadau diogelwch a datrys problemau.
Cynview Bylbiau Clyfar Globe Electric: Nodweddion, Gosod, a Chanllaw Rheoli Apiau
Dysgwch sut i sefydlu a rheoli eich Bwlb Clyfar Globe Electric gan ddefnyddio'r ap Globe Suite. Mae'r canllaw hwn yn ymdrin â nodweddion, manylebau, cyfarwyddiadau cysylltu, rheolyddion ap, ac integreiddio cynorthwyydd llais.
Cynview Canllaw Gosod a Llawlyfr Defnyddiwr Pecyn Cloch Drws Gwifredig Globe Smart
Canllaw cynhwysfawr ar gyfer gosod a defnyddio'r Pecyn Cloch Drws â Gwifrau Clyfar Globe (Model 18000156), gan gynnwys gosod, rheoli apiau, a datrys problemau.