Axis Communications 02621-001

Llawlyfr Defnyddiwr Switsh PoE++ Rheoledig Diwydiannol AXIS D8208-R 8-Porthladd

Model: 02621-001

1. Rhagymadrodd

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Axis Communications D8208-R Industrial 8-Port Managed PoE++ Switch. This device is designed for robust industrial environments, offering reliable network connectivity and Power over Ethernet (PoE++) capabilities for connected devices. Please read this manual thoroughly before using the product to ensure proper and safe operation.

2. Gwybodaeth Diogelwch

Dilynwch y rhagofalon diogelwch canlynol i atal difrod i'r cynnyrch a sicrhau diogelwch y defnyddiwr:

  • Ffynhonnell Pwer: Use only the specified power supply for this device. Ensure the power source meets the voltage a gofynion cyfredol.
  • Amgylchedd: Install the switch in an environment that complies with its operating temperature and humidity specifications. Avoid exposure to direct sunlight, excessive heat, moisture, or corrosive substances.
  • Awyru: Sicrhewch fod digon o awyru o amgylch y ddyfais i atal gorboethi. Peidiwch â rhwystro agoriadau awyru.
  • Gosod: Dylai'r gosodiad gael ei wneud gan bersonél cymwys yn unol â chodau a rheoliadau trydanol lleol.
  • Cynnal a Chadw: Do not attempt to open or service the device yourself. Refer all servicing to qualified service personnel.
  • Ceblau: Use appropriate and certified cables for all connections.

3. Cynnwys Pecyn

Verify that all items are present in the package. If any item is missing or damaged, contact your supplier.

  • AXIS D8208-R Industrial 8-Port Managed PoE++ Switch
  • Canllaw Gosod Cyflym
  • Mounting Kit (e.g., DIN rail clip, screws)
  • Terminal Block Connectors (for power input)

4. Cynnyrch Drosview

The AXIS D8208-R is a robust industrial switch designed for demanding applications. It features multiple Ethernet ports with Power over Ethernet capabilities and advanced management features.

4.1 Cynllun y Panel Blaen

Blaen view of AXIS D8208-R Industrial Switch showing ports and indicators

Ffigur 1: Blaen view of the AXIS D8208-R Industrial Switch. This image displays the front panel of the switch, highlighting the various Ethernet ports, power input terminals, LED indicators, and the console port. Ports 1-4 are 1G PoE++ ports, ports 5-8 include 1G and 2.5G PoE++ capabilities, and ports 9-10 are 10G SFP+ ports.

Blaen manwl view of AXIS D8208-R Industrial Switch

Ffigur 2: Blaen manwl view of the AXIS D8208-R Industrial Switch. This image provides a closer look at the port configuration and LED indicators. It shows the two 10G SFP+ uplink ports (9 and 10) at the bottom, the console port, and the reset button. The power input terminals are visible on the right side.

4.2 Components Description

  • Porthladdoedd Ethernet (1-4): 1 Gigabit Ethernet ports with PoE++ (802.3bt) support.
  • Porthladdoedd Ethernet (5-8): 1 Gigabit and 2.5 Gigabit Ethernet ports with PoE++ (802.3bt) support.
  • 10G Ports (9-10): 10 Gigabit SFP+ uplink ports for high-speed connections.
  • Power Input (P1, P2): Redundant power input terminals for enhanced reliability.
  • Porth Consol: RJ45 port for local management and configuration via a serial connection.
  • Botwm Ailosod: Fe'i defnyddir i ailosod y ddyfais i osodiadau diofyn y ffatri neu i ailgychwyn.
  • Dangosyddion LED:
    • SYS: Dangosydd statws system.
    • P1, P2: Power input status indicators.
    • ALM: Dangosydd larwm.
    • RM, RC: Redundancy Management / Redundancy Control indicators.

5. Gosod

5.1 Mowntio

The AXIS D8208-R is designed for DIN rail mounting.

  1. Attach the DIN rail clip (if not pre-installed) to the rear of the switch using the provided screws.
  2. Hook the top edge of the DIN rail clip onto the DIN rail.
  3. Push the bottom of the switch firmly towards the DIN rail until it clicks into place.
  4. Ensure the switch is securely fastened to the DIN rail.

5.2 Cysylltiad Pwer

The switch supports redundant power inputs (P1 and P2) for increased reliability.

  1. Ensure the power source is turned off before making any connections.
  2. Connect the positive (+) and negative (-) wires from your DC power supply to the corresponding terminals on the provided terminal block connector for P1.
  3. Insert the terminal block connector into the P1 power input port on the switch.
  4. (Optional) For redundant power, repeat steps 2 and 3 for the P2 power input.
  5. Once all connections are secure, turn on the power supply. The P1 and/or P2 LEDs should illuminate.

5.3 Cysylltiad Rhwydwaith

Connect network devices and uplink connections.

  • Standard Devices: Connect your network devices (e.g., IP cameras, access points) to ports 1-8 using standard Ethernet cables. These ports will provide PoE++ power if the connected device supports it.
  • Uplink: For high-speed uplink to your core network, insert compatible SFP+ transceivers into ports 9 and 10, then connect fiber optic cables.

5.4 Ffurfweddiad Cychwynnol

Gellir ffurfweddu'r switsh trwy a webrhyngwyneb seiliedig ar - neu ryngwyneb llinell orchymyn (CLI) trwy'r porthladd consol.

  • Web Rhyngwyneb: Connect a computer to any Ethernet port on the switch. The switch will typically obtain an IP address via DHCP or use a default static IP. Refer to the Quick Installation Guide for the default IP address and login credentials.
  • Porth Consol: Connect a serial cable from your computer to the console port on the switch. Use a terminal emulation program (e.g., PuTTY) with the specified serial settings (e.g., 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control) to access the CLI.

6. Gweithredu

6.1 Dangosydd LED

Monitor the LED indicators for the operational status of the switch.

LEDStatwsDisgrifiad
SYSGwyrdd (Solet)Mae'r system yn gweithredu'n normal.
SYSGwyrdd (Fflachio)System is booting or performing an operation.
Ll1/P2Gwyrdd (Solet)Corresponding power input is active.
ALMRed (Solid/Flashing)An alarm condition exists (e.g., power failure, port error). Check system logs.
LEDau porthladdoeddGwyrdd (Solet)Cyswllt wedi'i sefydlu.
LEDau porthladdoeddGwyrdd (Fflachio)Gweithgaredd data.

6.2 Rheolaeth a Chyfluniad

The AXIS D8208-R is a managed switch, offering a range of configuration options for network optimization and security.

  • WebGUI seiliedig ar: Mynediad i'r switsh web interface via a standard web browser to configure VLANs, QoS, port settings, PoE management, security features, and more.
  • CLI: For advanced users, the Command Line Interface provides granular control over all switch functions.
  • SNMP: The switch supports SNMP for integration with network management systems.

7. cynnal

7.1 Glanhau

To maintain optimal performance, periodically clean the exterior of the switch.

  • Sicrhewch fod y pŵer wedi'i ddatgysylltu cyn glanhau.
  • Defnyddiwch frethyn meddal, sych i sychu'r arwynebau allanol.
  • Peidiwch â defnyddio glanhawyr hylif na glanhawyr aerosol, gan y gallant niweidio'r ddyfais.
  • Keep ventilation openings clear of dust and debris.

7.2 Diweddariadau Firmware

Regularly check the Axis Communications website for the latest firmware updates. Firmware updates can provide new features, performance improvements, and security enhancements.

  • Lawrlwythwch y firmware priodol file from the official Axis Communications support page for your model.
  • Follow the instructions provided with the firmware update package for the correct update procedure, typically performed via the web rhyngwyneb.

8. Datrys Problemau

If you encounter issues with your AXIS D8208-R switch, refer to the following common troubleshooting steps.

  • Dim pŵer:
    • Check power cable connections to the switch and the power source.
    • Gwiriwch fod y cyflenwad pŵer yn gweithio'n gywir ac yn darparu'r cyfaint cywirtage.
    • Ensure the P1/P2 LEDs are illuminated.
  • Dim Cysylltedd Rhwydwaith:
    • Check Ethernet cable connections for both the switch and the connected device.
    • Verify the link/activity LEDs on the respective port are active.
    • Ensure the connected device is powered on and configured correctly.
    • Check switch configuration (VLANs, port status) via the web rhyngwyneb neu CLI.
  • Dyfais PoE Ddim yn Troi Ymlaen:
    • Ensure the connected device is PoE compatible and within the switch's PoE budget.
    • Check the PoE status for the port in the switch's management interface.
    • Verify the Ethernet cable is a standard Cat5e/6 or higher.
  • Cyrchu Web Interface Fails:
    • Confirm your computer's IP address is in the same subnet as the switch, or that DHCP is functioning.
    • Try accessing the switch via the console port to verify its IP configuration.
    • Cliriwch storfa eich porwr neu rhowch gynnig ar borwr gwahanol.
  • Ailosod Ffatri: If issues persist and you need to restore default settings, press and hold the reset button for approximately 10-15 seconds until the SYS LED changes behavior, then release. Rhybudd: Bydd hyn yn dileu'r holl gyfluniadau personol.

9. manylebau

NodweddManylyn
BrandCyfathrebu Echel
Rhif Model02621-001
Enw CynnyrchAXIS D8208-R Industrial 8-Port Managed PoE++ Switch
Porthladdoedd8 x PoE++ Ethernet (1G/2.5G), 2 x 10G SFP+
Mewnbwn PwerRedundant DC power input (terminal blocks)
Pwysau Eitem3.37 pwys (tua 1.53 kg)
Dimensiynau Pecyn1.97 x 0.79 x 0.79 modfedd (tua 5 x 2 x 2 cm)
GwneuthurwrAXIS - ACCESS CONTROL
Dyddiad Ar Gael CyntafMai 29, 2024

10. Gwarant a Chefnogaeth

For detailed warranty information, technical support, and additional resources, please visit the official Axis Communications websafle.

Websafle: www.axis.com

Contact Axis Communications support for assistance with product installation, configuration, or troubleshooting beyond the scope of this manual.

Dogfennau Cysylltiedig - 02621-001

Cynview Canllaw Ffurfweddu Switsh Rhwydwaith Axis - Gosod a Rheoli
Canllaw cynhwysfawr i weinyddwyr rhwydwaith ar ffurfweddu a rheoli switshis rhwydwaith AXIS T85 a D8208-R. Yn cwmpasu gosod, nodweddion, diogelwch a datrys problemau.
Cynview Canllaw Gosod AXIS High PoE Midspan a Splitters
Canllaw gosod ar gyfer Holltwyr AXIS T8123 High PoE Midspan ac AXIS T8126/T8128 High PoE, yn cwmpasu gosod, manylebau, a datrys problemau ar gyfer atebion Power over Ethernet.
Cynview Canllaw Gosod Synhwyrydd Ansawdd Aer AXIS D6310
Canllaw gosod cynhwysfawr ar gyfer Synhwyrydd Ansawdd Aer AXIS D6310. Dysgwch sut i osod, cysylltu a ffurfweddu eich dyfais yn ddiogel ac yn effeithiol. Yn cynnwys cydymffurfiaeth reoliadol, cyfarwyddiadau diogelwch a manylebau technegol.
Cynview AXIS M43 Panoramic Camera Series Installation Guide
This installation guide provides essential information for setting up the AXIS M43 Panoramic Camera Series, including models AXIS M4327-P and AXIS M4328-P. It covers installation procedures, safety, and regulatory compliance.
Cynview Llawlyfr ar gyfer defnydd o gamaras tipo domo AXIS M30
Guía gyflawn ar gyfer gosod, configuración a uso de las cámaras tipo domo AXIS M30, incluyendo detalles sobre imagen, fideo, sain, ceisiadau a ciberseguridad.
Cynview Canllaw Gosod Mowntiad Cilfachog AXIS TP3201-E
Mae'r canllaw hwn yn darparu cyfarwyddiadau ar gyfer gosod y Mowntiad Cilfachog AXIS TP3201-E, gan gynnwys gwybodaeth diogelwch, ystyriaethau cyfreithiol, a gweithdrefnau cydosod cam wrth gam ar gyfer modelau camera AXIS cydnaws.