Alcedo AE174

Alcedo Forehead and Ear Thermometer (Model AE174) User Manual

Your guide to accurate temperature measurement for adults, children, and infants.

1. Rhagymadrodd

This manual provides detailed instructions for the safe and effective use of your Alcedo Forehead and Ear Thermometer, Model AE174. Please read this manual thoroughly before first use and keep it for future reference. This device is designed for measuring human body temperature via the forehead or ear, and also for measuring object temperatures.

2. Cynnyrch Drosview a Chynnwys Pecyn

Alcedo Forehead and Ear Thermometer with packaging

Image: Alcedo Forehead and Ear Thermometer, Model AE174, shown with its retail packaging.

The Alcedo AE174 thermometer is a versatile device offering multiple measurement modes. Its design includes a magnetic probe cover for easy switching between forehead and ear modes.

Cynnwys y Pecyn:

Contents of the Alcedo thermometer package: thermometer, storage bag, 2 AAA batteries, user manual, quick start guide.

Image: All items included in the Alcedo thermometer package.

3. Nodweddion Allweddol

Diagram illustrating the four measurement modes: Non-contact Object Temperature, Non-contact Forehead Reading, Adult/Child Precision Technology, and Accurate Ear Measurement.

Image: Visual representation of the thermometer's 4-in-1 measurement capabilities.

4. Cydrannau Dyfais

Diagram showing the components of the Alcedo thermometer: Probe Cover, Probe, Power/Measure button, Mode button (Adult/Child/Ear/Object), °F/°C Switch, and Memory/Mute button.

Image: Labeled diagram of the Alcedo thermometer's external parts.

  1. Clawr y chwiliedydd: Protects the ear probe and enables forehead mode when attached.
  2. Archwiliwr: Infrared sensor for temperature measurement.
  3. Botwm Pŵer/Mesur: Turns the device on/off and initiates a measurement.
  4. Mode Button (Adult/Child/Ear/Object): Yn cylchdroi trwy wahanol ddulliau mesur.
  5. ° F/°C Switch: Toggles between Fahrenheit and Celsius temperature units.
  6. Memory/Mute Button: Accesses stored readings and activates/deactivates silent mode.

5. Gosod

5.1 Gosod Batri

Your Alcedo thermometer requires 2 AAA batteries (included). To install or replace batteries:

  1. Lleolwch glawr adran y batri ar gefn y ddyfais.
  2. Sleidwch y clawr yn agored.
  3. Mewnosodwch ddau fatri AAA, gan sicrhau'r polaredd cywir (+/-).
  4. Caewch y clawr adran batri yn ddiogel.

5.2 Initial Power On and Unit Selection

After installing batteries, press the Power/Measure button to turn on the thermometer. The device will perform a self-check and display the last reading. To switch between Fahrenheit (°F) and Celsius (°C), locate the °F/°C switch on the side of the device and slide it to your desired unit.

6. Cyfarwyddiadau Gweithredu

Ensure the thermometer has been in the same room as the user for at least 30 minutes before measurement for optimal accuracy.

6.1 Forehead Mode (Adult/Child)

Use this mode for non-contact temperature measurement on the forehead. The probe cover must be attached.

Three-step guide for forehead temperature measurement. Step 1: Choose Adult or Child mode. Step 2: Point thermometer 1-3cm from forehead. Step 3: Press and release measure button for instant reading.

Image: Step-by-step instructions for taking a forehead temperature.

  1. Ensure the probe cover is securely attached.
  2. Pwyswch y botwm Pŵer/Mesur i droi'r ddyfais ymlaen.
  3. Press the Mode button to select either Adult Forehead or Child Forehead mode.
  4. Point the thermometer probe to the center of the forehead, approximately 1-3 cm (0.4-1.2 inches) away from the skin surface.
  5. Press and release the Power/Measure button. The temperature will be displayed on the screen instantly.

Pwysig: Ensure there is no sweat, water, or condensation on the skin during forehead measurement.

6.2 Ear Mode

Use this mode for accurate temperature measurement inside the ear canal. The probe cover must be removed.

Three-step guide for ear temperature measurement. Step 1: Choose Ear mode. Step 2: Remove the magnetic probe cover. Step 3: Gently insert the probe into the ear canal and press the measure button. Not recommended for infants under 3 months.

Image: Step-by-step instructions for taking an ear temperature.

  1. Gently remove the magnetic probe cover. The device will automatically switch to Ear mode.
  2. Pwyswch y botwm Pŵer/Mesur i droi'r ddyfais ymlaen.
  3. Gently insert the probe into the ear canal. For children, gently pull the earlobe back and up to straighten the ear canal.
  4. Press and release the Power/Measure button. The temperature will be displayed instantly.

Pwysig: Ear mode is not recommended for infants under 3 months. Ensure the ear canal is clean and free of earwax for accurate readings.

6.3 Object Mode

Use this mode to measure the temperature of surfaces, liquids (like bath water), or food.

Three-step guide for object temperature measurement. Step 1: Choose Object mode. Step 2: Point thermometer 1-3cm from the object surface. Step 3: Press and release measure button for instant reading.

Image: Step-by-step instructions for taking an object temperature.

  1. Ensure the probe cover is attached.
  2. Pwyswch y botwm Pŵer/Mesur i droi'r ddyfais ymlaen.
  3. Pwyswch y botwm Modd i ddewis modd Gwrthrych.
  4. Point the thermometer probe to the center of the object, approximately 1-3 cm (0.4-1.2 inches) away from the surface.
  5. Press and release the Power/Measure button. The temperature will be displayed instantly.

6.4 Modd Tawel

To activate or deactivate silent mode, press and hold the Memory/Mute button for a few seconds until the mute icon appears or disappears on the display. This is useful for taking temperatures without disturbing a sleeping individual.

Image showing the thermometer in silent mode with a baby, indicating 1-second measurement and safe/hygienic use.

Image: The thermometer display showing the silent mode icon.

6.5 Swyddogaeth Cof

The thermometer automatically stores the last 20 temperature readings. To recall previous readings, press the Memory/Mute button briefly when the device is on. Each press will cycle through the stored readings.

6.6 Color-Coded Display and Fever Guidance

The display backlight changes color to provide a quick indication of temperature status:

Table showing color-coded display and sound indicators for normal and fever temperatures across different measurement modes.

Image: Table detailing temperature ranges, display colors, and sound alerts for normal and fever conditions.

Temperature Guidance Table
Math MesurYstod Tymheredd ArferolFever Temperature RangeArwyddiad Sain
Forehead (Adult/Child)35.0°C-37.5°C (95.0°F-99.5°F)37.6°C-42.2°C (99.6°F-108.0°F)Normal: A long beep; Fever: 3 short double beeps
Ear (Adult/Child)35.0°C-37.5°C (95.0°F-99.5°F)37.6°C-42.0°C (99.6°F-107.6°F)Normal: A long beep; Fever: 3 short double beeps
Tymheredd Gwrthrych0°C-100°C (32.0°F-212°F)AmhNormal: A long beep; Fever: 3 short double beeps

7. cynnal

7.1 Glanhau'r Thermomedr

Regular cleaning ensures accurate readings and extends the life of your thermometer.

7.2 Storio

Store the thermometer in its provided storage pouch in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.

8. Troubleshooting and Tips for Accurate Results

Tips for accurate results, including ensuring user and thermometer are in the same room for 30 minutes, cleaning the lens, ensuring no sweat on forehead, and not moving during measurement.

Image: Visual guide for ensuring accurate temperature readings.

9. manylebau

NodweddManylyn
Rhif ModelAE174
Moddau MesurForehead (Adult/Child), Ear, Object
Amser MesurTua 1 eiliad
Unedau TymhereddCelsius (°C) / Fahrenheit (°F)
Storio CofHyd at 20 o ddarlleniadau
Math ArddangosLCD gyda Backlight
Ffynhonnell Pwer2 x Batris AAA (wedi'u cynnwys)
Dimensiynau Cynnyrch6.61 x 1.97 x 1.93 modfedd
Pwysau4.3 owns
Deunydd AllanolPlastig
Technoleg CysyllteddIsgoch
Manyleb wedi'i ChwrddFDA
GwneuthurwrNature Major Inc.

10. Gwarant a Chefnogaeth

10.1 Gwybodaeth Gwarant

The Alcedo Forehead and Ear Thermometer (Model AE174) comes with a Gwarant cyfyngedig 1 mlynedd o ddyddiad y pryniant. Mae'r warant hon yn cwmpasu diffygion gweithgynhyrchu o dan ddefnydd arferol. Cadwch eich prawf prynu ar gyfer hawliadau gwarant.

10.2 Cefnogaeth i Gwsmeriaid

For any questions, concerns, or technical assistance, please contact Alcedo customer support. Alcedo Health provides US-based customer service to assist you.

Please refer to the contact information provided on the product packaging or the official Alcedo websafle am y manylion cymorth diweddaraf.