1. Cynnyrch Drosview
The Idec RJ2S-CL-D12 is an 8A DPDT (Double Pole Double Throw) electromechanical relay designed for general purpose switching applications. It operates on a 12VDC coil voltage and features a compact design suitable for various industrial electrical control systems. This relay is typically used for switching higher power circuits with a low power control signal, providing isolation between control and load circuits.

Figure 1: Idec RJ2S-CL-D12 Electromechanical Relay. This image shows the compact, transparent yellow casing of the relay, revealing the internal coil and contacts, with the pin base visible at the bottom.
2. Gwybodaeth Diogelwch
Always observe the following safety precautions when installing, operating, or maintaining the relay:
- Ensure all power is disconnected before installation or maintenance to prevent electric shock.
- Dim ond personél cymwysedig ddylai berfformio'r gosodiad.
- Gwirio cywir cyftage and current ratings before connecting the relay to a circuit.
- Do not exceed the specified current or voltage ratings of the relay.
- Amddiffynwch y ras gyfnewid rhag lleithder, llwch a thymheredd eithafol.
- Use appropriate wiring and connectors for the specified current load.
3. Gosod a Gosod
The RJ2S-CL-D12 relay is designed for socket mounting. Follow these steps for proper installation:
- Datgysylltu Pŵer: Before beginning, ensure that all power to the circuit where the relay will be installed is completely disconnected and locked out.
- Dewis Soced: Use a compatible relay socket (e.g., Idec SY4S-05 or similar) that matches the relay's pin configuration.
- Mounting the Socket: Securely mount the relay socket to a DIN rail or panel using appropriate fasteners.
- Wiring the Socket: Cysylltwch y rheolydd cyftage (12VDC) to the coil terminals of the socket. Refer to the socket's wiring diagram for correct polarity. Connect the load circuit wires to the appropriate contact terminals (common, normally open, normally closed) as required by your application. The DPDT configuration provides two independent sets of contacts.
- Inserting the Relay: Carefully align the relay pins with the corresponding holes in the socket. Gently push the relay into the socket until it is fully seated. Do not force the relay, as this may bend or damage the pins.
- Dilysu: Gwiriwch yr holl gysylltiadau gwifrau ddwywaith am gywirdeb a diogelwch cyn adfer y pŵer.
4. Cyfarwyddiadau Gweithredu
The RJ2S-CL-D12 relay operates by energizing its coil, which then actuates the internal contacts to switch the connected load circuits.
- Coil Activation: When 12VDC is applied across the coil terminals, an electromagnetic field is generated, pulling the armature and changing the state of the contacts.
- Contact Switching:
- Normally Open (NO) contacts will close.
- Normally Closed (NC) contacts will open.
- Analluogi: When the 12VDC supply to the coil is removed, the electromagnetic field collapses, and the contacts return to their original (de-energized) state.
- Dangosydd: Many compatible sockets or the relay itself may feature an LED indicator to show when the coil is energized.
5. cynnal
Electromechanical relays like the RJ2S-CL-D12 are generally low-maintenance devices. However, periodic inspection can help ensure reliable operation.
- Archwiliad gweledol: Periodically inspect the relay and its socket for any signs of physical damage, discoloration (indicating overheating), or loose connections.
- Glanhau: If dust or debris accumulates, gently clean the exterior of the relay and socket using a soft, dry cloth. Do not use solvents or abrasive cleaners.
- Gwisg Cyswllt: While not typically user-serviceable, excessive arcing or frequent switching of high inductive loads can lead to contact wear over time. If erratic behavior or failure to switch is observed, consider replacing the relay.
- Amodau Amgylcheddol: Sicrhewch fod yr amgylchedd gweithredu yn aros o fewn yr ystodau tymheredd a lleithder penodedig i atal methiant cynamserol.
6. Datrys Problemau
If the RJ2S-CL-D12 relay is not functioning as expected, consider the following troubleshooting steps:
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Relay coil does not energize (no click, no indicator light) |
|
|
| Relay energizes but load does not switch |
|
|
| Relay buzzes or chatters |
|
|
7. manylebau
| Priodoledd | Gwerth |
|---|---|
| Rhif Model | RJ2S-CL-D12 |
| Brand | Idec |
| Math Cyswllt | DPDT (Tafliad Dwbl Pol Dwbl) |
| Coil Voltage | 12VDC |
| Graddfa Gyfredol | 8 Amps |
| Ymwrthedd Coil | 271 Ohms |
| Dimensiynau (tua) | 28.8 x 12.7 x 33 mm |
| Modd Gweithredu | Awtomatig |
| Gwneuthurwr | IDEC |
8. Gwarant a Chefnogaeth
Specific warranty terms and conditions for the Idec RJ2S-CL-D12 relay are not provided in this manual. For detailed warranty information, technical support, or service inquiries, please contact Idec Corporation directly or refer to their official websafle.
You may also contact the authorized distributor or seller from whom you purchased the product for assistance.





