FSP iFP600 Uninterruptible Power Supply (UPS) User Manual

Model: iFP 600

1. Rhagymadrodd

This manual provides essential instructions for the installation, operation, and maintenance of your FSP iFP600 Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installing or operating the unit to ensure proper function and safety. The FSP iFP600 is designed to provide reliable power backup and surge protection for your electronic devices.

FSP iFP600 UPS front view gydag arddangosfa LCD

Delwedd 1.1: Blaen view of the FSP iFP600 UPS, showcasing its compact design and integrated LCD display.

2. Cyfarwyddiadau Diogelwch

Please adhere to these important safety guidelines during installation, operation, and maintenance of the UPS:

  • Peidiwch ag agor yr UPS casing. Nid oes unrhyw rannau y gall y defnyddiwr eu gwasanaethu y tu mewn. Cyfeiriwch yr holl waith cynnal a chadw at bersonél gwasanaeth cymwys.
  • Do not connect appliances that could overload the UPS, such as laser printers, vacuum cleaners, or heaters.
  • Sicrhewch fod yr UPS wedi'i gysylltu ag allfa pŵer AC wedi'i seilio.
  • Avoid placing the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
  • Position the UPS in a well-ventilated area to prevent overheating.
  • In case of fire, use a dry chemical extinguisher. Water can be hazardous.
  • The battery inside the UPS is not user-replaceable. Battery replacement should only be performed by qualified personnel.

3. Cynnyrch Drosview

The FSP iFP600 UPS provides reliable power protection for your critical electronics. It features a compact design and an intuitive LCD display for monitoring status.

3.1 Cynnwys Pecyn

Wrth agor y pecyn, gwiriwch fod yr holl gydrannau yn bresennol ac yn ddi-ddifrod:

  • FSP iFP600 UPS Unit
  • Llawlyfr Defnyddiwr (y ddogfen hon)
  • Cord Pŵer
  • Cebl Cyfathrebu USB
FSP iFP600 UPS with its retail packaging

Image 3.1: The FSP iFP600 UPS shown alongside its retail packaging, illustrating the product's presentation.

3.2 Cydrannau'r Panel Cefn

Familiarize yourself with the connections on the rear panel of the UPS:

Rear panel of FSP iFP600 UPS showing outlets, AC input, fuse, USB, and RJ11/RJ45 ports

Delwedd 3.2: Manwl view of the FSP iFP600 UPS rear panel, highlighting connection points.

  1. Allfeydd: Two SCHUKO type outlets for connecting protected equipment.
  2. Mewnbwn AC: Connects the UPS to the main utility power.
  3. Fuse/Breaker: Overcurrent protection for the UPS.
  4. Cyfathrebu USB: Port for connecting to a computer for monitoring and management.
  5. Combo RJ11/RJ45 Surge Protection: Provides surge protection for telephone/network lines.

4. Gosod a Gosod

Follow these steps to set up your FSP iFP600 UPS:

  1. Dadbacio: Carefully remove the UPS from its packaging. Inspect for any shipping damage.
  2. Lleoliad: Place the UPS on a flat, stable surface in a clean, cool, and well-ventilated area. Ensure adequate clearance around the unit for airflow.
  3. Tâl Cychwynnol: Connect the UPS to a standard grounded AC outlet using the provided power cord. Allow the unit to charge for at least 4-6 hours before initial use to ensure optimal battery performance. The UPS will charge whether it is turned on or off.
  4. Offer cysylltu: Plug your computer, monitor, and other critical electronic devices into the UPS outlets (A). Do not connect surge suppressors or power strips to the UPS outlets.
  5. USB Communication (Optional): Connect the USB cable from the UPS USB port (D) to your computer's USB port to enable power management software features (software not included, typically downloaded from manufacturer's websafle).
  6. RJ11/RJ45 Protection (Optional): For surge protection of your telephone or network line, connect the incoming line to the 'IN' port of the Combo RJ11/RJ45 (E) and connect the 'OUT' port to your device.

5. Cyfarwyddiadau Gweithredu

5.1 Pweru Ymlaen/Diffodd

  • I Bweru Ymlaen: Press and hold the power button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates.
  • I Bweru i ffwrdd: Press and hold the power button for approximately 2 seconds until you hear a beep and the LCD display turns off.

5.2 Gwybodaeth Arddangosfa LCD

The FSP iFP600 features an LCD display that provides real-time status information. The display is touch-sensitive for navigating information.

Close-up of FSP iFP600 UPS LCD display showing '230V' and a finger touching it

Image 5.1: The LCD display of the FSP iFP600 UPS, indicating voltage output and its touch-screen functionality.

The LCD display typically shows:

  • Mewnbwn Voltage
  • Allbwn Voltage
  • Lefel Tâl Batri
  • Lefel Llwyth
  • Operating Mode (e.g., AC mode, Battery mode)
  • Warning/Fault Indicators

5.3 Battery Mode Operation

When the utility power fails or fluctuates outside acceptable limits, the UPS will automatically switch to battery mode. During battery mode, the UPS will provide power to connected equipment from its internal battery. An audible alarm will sound to indicate battery operation.

6. cynnal

Proper maintenance ensures the longevity and reliability of your UPS.

  • Glanhau: Use a soft, dry cloth to clean the exterior of the UPS. Do not use liquid or aerosol cleaners.
  • Gofal Batri: To maximize battery life, ensure the UPS is connected to AC power and fully charged. If the UPS is stored for an extended period, recharge it every three months to prevent battery degradation.
  • Amnewid Batri: The internal battery (12V / 7Ah x1) is not user-serviceable. Battery replacement should only be performed by FSP-certified service personnel or a qualified technician. Incorrect battery replacement can pose a risk of explosion or injury.
  • Storio: Store the UPS in a cool, dry place with adequate ventilation. Ensure the battery is fully charged before storage.

7. Datrys Problemau

Refer to the following table for common issues and their solutions. If the problem persists, contact FSP support.

SymptomauLarwm ClywadwyAchos PosiblAteb
UPS operating on battery powerBeeps bob 10 eiliadUtility power failure or fluctuationSave work and shut down equipment if power outage is prolonged. UPS will return to AC mode when power is restored.
Rhybudd batri iselBîp bob eiliadMae gwefr y batri yn isel iawnImmediately save work and shut down connected equipment.
Cyflwr gorlwythoBîp bob 0.5 eiliadConnected equipment exceeds UPS capacityDisconnect non-essential equipment until the alarm stops. Ensure total load is within UPS capacity.
UPS faiCanu yn barhausNam mewnol neu gamweithioTurn off the UPS and disconnect it from the AC outlet. Contact FSP technical support.
Specification table for FSP iFP series UPS models, including alarm indicators

Image 7.1: Excerpt from the FSP iFP series specification table, detailing alarm indicators and their meanings.

8. manylebau

Detailed technical specifications for the FSP iFP600 UPS:

NodweddManyleb
ModeliFP 600
Gallu600 VA / 360 W
Mewnbwn Voltage110/120 Vac or 220/230/240 Vac
Mewnbwn Voltage Ystod81-145 Vac / 140-290 Vac
Ystod Amlder Mewnbwn60/50 Hz (synhwyro awtomatig)
Allbwn Voltage110/120 Vac or 220/230/240 Vac
AC Cyftage Rheoliad (Modd Ystlumod)±10%
Output Frequency Range (Batt. Mode)60 Hz or 50 Hz ±1 Hz
Amser TrosglwyddoNodweddiadol 2-6 ms
Waveform (Modd Batt.)Sinewave Efelychu
Math a Rhif Batri12V / 7Ah x1
Amser Ad-daliad Nodweddiadol4 awr hyd at 90% o'r capasiti
DangosyddionLCD Display (Touch panel with digital information)
AmddiffyniadOverload, Discharge, and Overcharge Protection
Pwysau Eitem9.24 pwys (4.2 kg)
Dimensiynau Cynnyrch (LxWxH)11.81 x 3.98 x 5.59 modfedd
LliwDu
DeunyddMetel

9. Gwarant a Chefnogaeth

FSP products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official FSP website. For technical support, troubleshooting assistance, or service inquiries, please contact FSP customer service through their official channels.

Gallwch ddod o hyd i ragor o wybodaeth ac adnoddau cymorth ar y FSP Store on Amazon.

Dogfennau Cysylltiedig - iFP 600

Cynview Guia do Utilizador FSP Online UPS 1K/2K/3K
Este manual fornece instruções essenciais de segurança, instalação e operação para os sistemas FSP Online UPS modelos 1K, 2K e 3K, cobrindo especificações técnicas e manutenção.
Cynview Manuale Utente FSP Online UPS 1K/2K/3K: Guida Completa
Scopri come installare, configurare e utilizzare il tuo FSP Online UPS 1K, 2K o 3K con questo manuale utente dettagliato. Include precauzioni di sicurezza, specifiche tecniche e guide alla manutenzione.
Cynview Manual do Utilizador FSP Online UPS 1K/2K/3K: Segurança, Instalação e Especificações
Guia completo para o FSP Online UPS 1K/2K/3K, cobrindo precauções de segurança essenciais, instruções detalhadas de instalação e configuração, orientações de uso, manutenção e especificações técnicas para garantir o desempenho ideal.
Cynview UPS Ar-lein FSP 1K/2K/3K Cyfeiriadur a Manyleb
Denna guide ger detaljerade instruktioner for installation, drifft a thanhåll av FSP Online UPS modellerna 1K, 2K a 3K. Innehåller säkerhetsvarningar, tekniska specifikationer a felsökningsinformation.
Cynview UPS Ar-lein FSP 1K/2K/3K Felhasználói Kézikönyv is Útmutató
Ez a dokumentum az FSP Online UPS 1K, 2K és 3K sorozat biztonságos és hatékony üzemeltetéséhez nyújt alapvető információkat. Részletezi a fontos biztonsági óvintézkedéseket, a lépésről lépésre történő telepítési eljárásokat és a helyes használatra vonatkozó útmutatásokat. A felhasználók átfogó utasításokat találnak az UPS csatlakoztatásához, működési módjainak megértéséhez és az alapvető karbantartás elvégzéséhez. Az útmutató továbbá ismerteti a hibaelhárítási lépéseket és az FSP Online UPS modellek műszaki specifikációit.
Cynview Llawlyfr Defnyddiwr UPS Ar-lein Rac/Tŵr FSP 1K/1.5K/2K/3K
Llawlyfr defnyddiwr cynhwysfawr ar gyfer modelau UPS Ar-lein Rac/Tŵr FSP 1K, 1.5K, 2K, a 3K. Mae'r canllaw hwn yn ymdrin â chyfarwyddiadau diogelwch, gosod, gweithredu, cynnal a chadw, datrys problemau, a manylebau technegol manwl.