TCI E0882-25G

Llawlyfr Cyfarwyddiadau Cynnyrch

Cynnyrch: Ethyl Isobutyrylacetate

Model: E0882-25G

Brand: TCI America

1. Cynnyrch Drosview

This manual provides essential information for the safe and effective handling, storage, and use of Ethyl Isobutyrylacetate (E0882-25G) supplied by TCI America.

Ethyl Isobutyrylacetate is an organic reagent primarily intended for laboratory research and development applications. It is a carbonyl compound and a key building block in organic chemistry.

Product packaging for Ethyl Isobutyrylacetate

Image: Typical packaging for TCI America chemical reagents, including Ethyl Isobutyrylacetate.

2. Gwybodaeth Diogelwch a Rhagofalon

WARNING: This product is for laboratory research use only. It is not intended for human or animal use, or as a component in food, drugs, medical devices, cosmetics, or pesticides.

Always consult the Safety Data Sheet (SDS) for comprehensive safety information before handling this chemical. Key precautions include:

  • Wear appropriate Personal Protective Equipment (PPE), including safety goggles, gloves, and a lab coat.
  • Work in a well-ventilated area or under a fume hood to avoid inhalation of vapors.
  • Avoid contact with skin, eyes, and clothing. In case of contact, rinse immediately with plenty of water and seek medical advice.
  • Peidiwch â llyncu. Os caiff ei lyncu, ceisiwch sylw meddygol ar unwaith.
  • Cadwch y cynhwysydd ar gau'n dynn pan nad yw'n cael ei ddefnyddio.
  • Storio i ffwrdd o ddeunyddiau anghydnaws.

3. Manylebau Cynnyrch

Detailed chemical and physical properties of Ethyl Isobutyrylacetate (E0882-25G):

EiddoGwerth
Enw CemegolEthyl Isobutyrylacetate
Rhif CAS7152-15-0
MDL NumberMFCD00009198
Purity (GC)>95.0%
Fformiwla MoleciwlaiddC8H14O3
Pwysau Moleciwlaidd158.20
Berwbwynt90 °C
CyfystyronIsobutyrylacetic Acid Ethyl Ester, Ethyl 4-Methyl-3-oxovalerate, 4-Methyl-3-oxovaleric Acid Ethyl Ester
Chemical structure of Ethyl Isobutyrylacetate

Image: Chemical structure of Ethyl Isobutyrylacetate (C8H14O3).

4. Trin a Storio

4.1. Receiving and Initial Inspection

Upon receipt, inspect the packaging for any signs of damage or leakage. Ensure the product label matches the order and the container is sealed. Store immediately according to recommended conditions.

4.2. Amodau Storio

Store Ethyl Isobutyrylacetate at a temperature range of 15-25 °C (room temperature). Keep the container tightly closed in a dry, well-ventilated place. Protect from light and moisture. Ensure storage area is secure and accessible only to authorized personnel.

4.3. General Handling Guidelines

  • Handle with care to prevent spills.
  • Use clean, dry glassware and equipment.
  • Avoid cross-contamination with other chemicals.
  • Always return unused material to its original container if possible, or dispose of properly.

5. Canllawiau Defnydd

Ethyl Isobutyrylacetate is used as an organic reagent in various chemical synthesis and research applications. Specific usage protocols will depend on the intended experimental design.

5.1. Cais

This chemical is categorized under Organic Reagents and Carbonyl Compounds [Non-Heterocyclic Building Blocks]. It serves as a versatile building block for synthesizing more complex organic molecules.

5.2. Purity Considerations

The product is supplied with a purity of >95.0% (GC). For sensitive applications, users should consider verifying purity before use. Impurities may affect reaction outcomes.

6. Emergency Procedures and Disposal

6.1. Spill Response

In case of a spill, immediately evacuate the area if necessary and ensure proper ventilation. Wear appropriate PPE. Absorb the spilled material with an inert absorbent (e.g., sand, vermiculite, diatomaceous earth). Collect in a suitable container for disposal. Do not allow product to enter drains or watercourses.

6.2. First Aid

  • Anadlu: Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
  • Cyswllt croen: Wash off with soap and plenty of water. Consult a physician if irritation develops.
  • Cyswllt Llygaid: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
  • Amlyncu: Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

6.3. Gwaredu Gwastraff

Dispose of contents and container in accordance with local, regional, national, and international regulations. Chemical waste should be handled by licensed waste disposal contractors.

7. Ymwadiad Cyfreithiol

TCI America's products are intended primarily for laboratory use and, unless otherwise indicated on TCI America's invoice, other writings, or on product labels, are not to be used for other purposes, including, but not limited to, human or animal use, or a component in, a food, drug, or medical device (including in vitro diagnostic reagents) or cosmetics as defined in the Federal Food, Drug and Cosmetic Act, as amended, nor as a pesticide as defined in the Federal Insecticide, Fungicide and Rodenticide Act, as amended. Buyer acknowledges that the products purchased hereunder have not been tested by TCI America for safety and efficacy in a food, drug, cosmetic or pesticide unless otherwise stated by TCI America in writing furnished to Buyer. Buyer expressly represents and warrants to TCI America that Buyer will properly test, use, manufacture and market any products purchased from TCI America. For full disclaimer, see TCI Terms and conditions.

8. Cymorth a Chyswllt

For technical support, product inquiries, or to access the Safety Data Sheet (SDS), please visit the official TCI America website or contact their customer service. TCI America is a division of Tokyo Chemical Industry, offering a wide range of high-quality organic reagents for research and development.

Assortment of TCI America chemical products

Image: A selection of chemical products from TCI America.

Gallwch ddod o hyd i ragor o wybodaeth a manylion cyswllt drwy ymweld â’r TCI Store on Amazon neu eu corfforaethol swyddogol websafle.

Dogfennau Cysylltiedig - E0882-25G

Cynview TCI TCI-2500D 2-Channel Class D Power AmpLlawlyfr Defnyddiwr lifier
Comprehensive user manual for the TCI TCI-2500D 2-Channel Class D Power Amplifier, covering safety, features, installation, connections, and detailed specifications for models TCI-2120D, TCI-2240D, TCI-2350D, and TCI-2500D.
Cynview TCI BT/USB/TF/FM Mixer Amplifier User Manual - Features, Specifications, and Connections
Comprehensive user manual for the TCI BT/USB/TF/FM Mixer Amplifier series (TCI-60CMT, TCI-120CMT, TCI-240CMT), covering setup, operation, safety, specifications, connection diagrams, speaker wiring, and Bluetooth pairing.
Cynview TCI Outdoor Column Speaker User Manual (TCI-L603, TCI-L604)
User manual for TCI Outdoor Column Speakers, models TCI-L603 and TCI-L604. Includes installation steps, exterior design details, specifications, wiring instructions, and technical parameters.
Cynview Siaradwr Nenfwd Gwrth-ddŵr TCI-406W - Manylebau Technegol a Gosod
Manylebau technegol manwl, nodweddion, a chanllaw gosod ar gyfer y siaradwr nenfwd gwrth-ddŵr TCI-406W, wedi'i gynllunio ar gyfer atgynhyrchu sain o ansawdd uchel mewn amgylcheddau dan do.
Cynview TCI TCI-IP532 Alarm Signal Collector User Manual
User manual for the TCI TCI-IP532 Alarm Signal Collector, detailing its product description, features, front and rear panel layouts, and technical specifications for network alarm input and output.
Cynview 16 Zone Selector TCI-1608Z User Manual and Safety Instructions
Detailed information on the TCI-1608Z 16 Zone Selector, including safety instructions, features, front and rear panel descriptions, system diagram, and specifications. This device allows for flexible management of audio zones for background music and paging.