1. Cynnyrch Drosview
The Orbit RN-50-300 is a rigid nipple designed for use in electrical conduit systems. It provides a secure and durable connection between two threaded conduit components, ensuring proper grounding and protection of electrical wiring. This specific model features a 1/2-inch trade size and a 3-inch length, making it suitable for various standard installations.

Figure 1: Assortment of rigid nipples, similar to the Orbit RN-50-300. The product is a metallic, cylindrical pipe segment with external threads on both ends, used for connecting electrical conduits.
Nodweddion Allweddol:
- Model: RN-50-300
- Maint: 1/2 modfedd x 3 modfedd
- Deunydd: Typically galvanized steel or other corrosion-resistant metal.
- Cais: Electrical conduit systems, providing rigid connections.
- Cydymffurfiaeth: Designed to meet industry standards for electrical fittings.
2. Gwybodaeth Diogelwch
Always follow local electrical codes and safety regulations when installing electrical components. Failure to do so may result in electrical shock, fire, or property damage.
- Ensure power is disconnected before beginning any installation.
- Gwisgwch offer amddiffynnol personol (PPE) priodol, gan gynnwys sbectol ddiogelwch a menig.
- Use only tools designed for electrical work.
- Ymgynghorwch â thrydanwr cymwys os ydych yn ansicr ynghylch unrhyw ran o'r broses osod.
3. Gosod (Sefydlu)
The RN-50-300 rigid nipple is designed for straightforward installation in threaded conduit systems.
- Paratoi Cydrannau: Ensure both conduit sections or fittings you intend to connect have clean, properly threaded openings. Remove any burrs or debris.
- Apply Thread Sealant (Optional): For applications requiring a watertight or airtight seal, apply a suitable thread sealant or PTFE tape to the threads of the rigid nipple.
- Thread Nipple: Carefully thread one end of the RN-50-300 rigid nipple into the first conduit component. Hand-tighten initially to ensure proper alignment and prevent cross-threading.
- Connect Second Component: Thread the second conduit component onto the other end of the rigid nipple.
- Tynhau Cysylltiadau: Use a pipe wrench or appropriate tool to securely tighten both connections. Do not overtighten, as this can damage the threads or components. Ensure the connection is firm and stable.
- Gwirio Cysylltiad: Visually inspect the connection to ensure the nipple is fully engaged and the conduit components are aligned correctly.
4. Gweithrediad
The Orbit RN-50-300 rigid nipple is a passive component and does not have operational controls. Its function is to provide a fixed, rigid connection within an electrical conduit system, facilitating the safe routing and protection of electrical conductors.
Once installed, ensure the conduit system remains intact and free from physical damage or excessive strain that could compromise the integrity of the connections.
5. cynnal
The RN-50-300 rigid nipple requires minimal maintenance once properly installed. Regular inspections of the conduit system are recommended to ensure long-term performance and safety.
- Archwiliad gweledol: Periodically inspect the nipple and surrounding conduit for signs of corrosion, physical damage, or loosening.
- Glendid: Keep the area around the conduit connections clean and free of excessive dust, dirt, or moisture, which could contribute to corrosion.
- Gwiriad Tyndra: If accessible and safe to do so (with power disconnected), occasionally check the tightness of the connections to ensure they have not vibrated loose over time.
- Amnewid: If the nipple shows signs of significant corrosion, cracking, or other damage, it should be replaced immediately by a qualified professional.
6. Datrys Problemau
As a passive component, troubleshooting for the rigid nipple primarily involves identifying issues related to its installation or integrity within the conduit system.
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Cysylltiad Rhydd | Insufficient tightening during installation; vibration over time. | Disconnect power, then re-tighten the nipple connections using appropriate tools. |
| Corrosion/Rust | Exposure to moisture or harsh environments; damaged protective coating. | Replace the nipple if corrosion is severe. Consider using corrosion-resistant fittings or protective coatings in corrosive environments. |
| Damaged Threads | Cross-threading during installation; overtightening; physical impact. | The nipple must be replaced. Ensure proper alignment and avoid overtightening during new installation. |
| Dwfr yn Dyfodiad | Improperly sealed connections; lack of thread sealant in wet locations. | Disconnect power, disassemble, apply appropriate thread sealant (e.g., PTFE tape or pipe dope), and reassemble. Ensure proper drainage if applicable. |
Nodyn: Always ensure power is disconnected before attempting any troubleshooting or maintenance on electrical conduit systems.
7. manylebau
| Priodoledd | Manylyn |
|---|---|
| Rhif Model | RN-50-300 |
| Brand | orbit |
| Math o Gysylltydd | Deth |
| Maint Edau | 0.5 inch (1/2") |
| Hyd | 3 modfedd |
| Deunydd | Galvanized Steel (Typical for rigid nipples) |
| Cais | Electrical Conduit Systems |
8. Gwarant a Chefnogaeth
For specific warranty information and technical support regarding the Orbit RN-50-300 Rigid Nipple, please refer to the official Orbit Industries websafle neu cysylltwch â'u gwasanaeth cwsmeriaid yn uniongyrchol.
Orbit Industries Contact Information:
- Websafle: www.orbitindustries.com (Nodyn: Mae hwn yn ddaliwr lle URL as specific support links were not provided.)
- Gwasanaeth Cwsmer: Gwiriwch y swyddogol websafle am y manylion cyswllt diweddaraf, gan gynnwys rhifau ffôn a chyfeiriadau e-bost.
Always retain your purchase receipt for warranty claims.