1. Rhagymadrodd
Y LogTag UTRIX-16 is a high-performance, multi-use temperature data logger designed for reliable and accurate monitoring across a wide range of applications. This device records temperature data and generates comprehensive PDF reports without requiring special software or hardware. Its integrated USB connector allows for easy data transfer and configuration.
2. Gwybodaeth Diogelwch
- Do not expose the device to extreme physical shock or vibration.
- Avoid immersing the device in liquids.
- Do not attempt to open or modify the device, as this will void the warranty and may cause damage.
- Cael gwared ar fatris yn unol â rheoliadau lleol.
- Ensure the USB connector is clean and dry before connecting to a computer.
3. Cynnwys Pecyn
Gwiriwch fod yr holl eitemau yn bresennol yn y pecyn:
- LogTag UTRIX-16 PDF Temperature Data Logger
- Llawlyfr Defnyddiwr (y ddogfen hon)
4. Dyfais Drosoddview
The UTRIX-16 features a compact design with clear indicators and control buttons.
Ffigur 1: Blaen view of the LogTag UTRIX-16 PDF Temperature Data Logger. This image displays the device's front panel, showing the "ALERT" and "OK" indicator lights, and the "STOP" and "START/Mark" buttons. The LogTag brand and "USB PDF TEMPERATURE RECORDER" text are visible, along with a serial number barcode.
- ALERT Indicator: Flashes when a pre-configured temperature alert threshold has been exceeded.
- OK Indicator: Flashes to confirm normal operation and within-range temperature readings.
- Botwm STOPIO: Press to stop the current logging session.
- START/Mark Button: Press to start a new logging session or to insert a mark into the data stream during logging.
- Integrated USB Connector: Located at the bottom, used for connecting to a computer for configuration and data download.
Ffigur 2: Y LogTag UTRIX-16 with its integrated USB connector extended. This view highlights the USB-A plug, ready for connection to a computer's USB port, facilitating direct data transfer and device configuration.
5. Gosod
5.1 Ffurfweddiad Cychwynnol
The UTRIX-16 is typically pre-configured for immediate use. However, for custom settings (e.g., logging interval, alert thresholds, start delay), you will need to use the LogTag Analyzer software. This software is available for download from the official LogTag websafle.
- Download and install the LogTag Meddalwedd dadansoddwr o LogTag Recorders Software.
- Connect the UTRIX-16 to a USB port on your computer.
- Y LogTag Analyzer software should automatically detect the connected device.
- Follow the on-screen prompts within the software to configure logging parameters as needed.
Ffigur 3: Y LogTag UTRIX-16 data logger connected to a computer's USB port. This illustrates the direct connection method for data download and configuration, eliminating the need for a separate interface cradle.
5.2 Gwybodaeth Batri
The UTRIX-16 uses a CR2 battery (included). The battery is designed for long life and is generally not user-replaceable without specialized tools. If battery replacement is required, it is recommended to contact LogTag support or an authorized service center.
6. Gweithrediad
6.1 Starting a Logging Session
To start a new logging session:
- Ensure the device is not currently logging (check the OK/ALERT indicators).
- Pwyswch a dal y DECHRAU/Marc button for approximately 5 seconds until the OK indicator flashes rapidly.
- Release the button. The OK indicator will flash at regular intervals, indicating that logging has started.
6.2 Stopping a Logging Session
To stop an active logging session:
- Pwyswch a dal y AROS button for approximately 5 seconds until the ALERT indicator flashes rapidly.
- Release the button. The device will cease logging.
6.3 Marking Data
During an active logging session, you can insert a mark into the data stream:
- Pwyswch yn fyr y DECHRAU/Marc button (less than 2 seconds).
- A mark will be recorded in the data, visible when the data is downloaded and analyzed.
7. Data Retrieval and Reporting
The UTRIX-16 generates a PDF report directly when connected to a computer.
- Connect the UTRIX-16 to a USB port on your computer.
- The device will appear as a removable drive.
- Locate and open the generated PDF report file. This report contains a summary of the logging session, temperature graphs, and statistical data.
- For advanced analysis and configuration, use the LogTag Meddalwedd dadansoddwr.
8. cynnal
8.1 Glanhau
Sychwch y ddyfais yn lân gyda lliain meddal, damp brethyn. Peidiwch â defnyddio glanhawyr neu doddyddion sgraffiniol.
8.2 Batri Newydd
The battery in the UTRIX-16 is designed for extended use and is not intended for user replacement. If the battery life is depleted, contact LogTag support for service options.
9. Datrys Problemau
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Device does not start logging. | Incorrect button press duration; device already logging; battery depleted. | Ensure the START/Mark button is held for approximately 5 seconds. Check if the device is already logging. Connect to LogTag Analyzer to check battery status. |
| Computer does not recognize the device. | Loose USB connection; faulty USB port; driver issue. | Ensure the USB connector is fully inserted. Try a different USB port. Reinstall LogTag Meddalwedd dadansoddwr. |
| No PDF report generated. | Logging session not completed; device not recognized as a drive. | Ensure the logging session has been stopped. Verify the device appears as a removable drive. |
| ALERT indicator flashing. | Temperature exceeded pre-set limits. | This indicates an alert condition. Review the PDF report or LogTag Analyzer data to identify when and for how long the limits were exceeded. |
10. manylebau
| Nodwedd | Manylyn |
|---|---|
| Rhif Model | UTRIX-16 |
| Amrediad Tymheredd | -25°C i +70°C (-13°F i +158°F) |
| Cysylltedd | USB integredig |
| Ffynhonnell Pwer | 1 batri CR2 (wedi'i gynnwys) |
| Dimensiynau Cynnyrch | 3.66 x 2.15 x 0.34 modfedd |
| Pwysau | 1.27 owns |
| Deunydd | Plastig |
| Nodwedd Arbennig | High Accuracy, PDF Reporting |
11. Gwarant a Chefnogaeth
LogTag products are manufactured to high standards. For warranty information and technical support, please refer to the official LogTag websafle neu cysylltwch â'ch dosbarthwr lleol. Cadwch eich derbynneb prynu fel prawf o brynu.
Official LogTag Websafle: www.logtag-recorders.com