Rhagymadrodd
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Idec RH2B-UL-AC110-120V Electromechanical Relay. Please read this manual thoroughly before using the product to ensure proper function and to prevent potential hazards.
Gwybodaeth Diogelwch
WARNING: Electrical shock hazard. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working with the relay.
- Always ensure power is disconnected before installation, wiring, or maintenance.
- Gwirio cywir cyftage and current ratings before connecting the relay to a circuit.
- Do not operate the relay in environments exceeding its specified temperature or humidity limits.
- Ensure proper grounding where applicable.
Cynnyrch Drosview
The Idec RH2B-UL-AC110-120V is a general-purpose electromechanical relay designed for various industrial control applications. It features a compact design and is suitable for DIN rail mounting.

Figure 1: Idec RH2B-UL-AC110-120V Relays in their original packaging, showing a pack of four units.

Figure 2: A single Idec RH2B-UL-AC110-120V relay, providing an angled view of the transparent casing a chydrannau mewnol.
Gosod a Gosod
Follow these steps for proper installation of the Idec RH2B-UL-AC110-120V Relay:
- Datgysylltu Pŵer: Ensure all power to the circuit is completely disconnected before beginning installation.
- Mowntio: The relay is designed for DIN Rail mounting. Securely attach the relay to a standard DIN rail in your control panel.
- Gwifrau: The relay utilizes through-hole connectors. Carefully connect the control circuit wiring to the coil terminals and the load circuit wiring to the contact terminals. Refer to the wiring diagram (if available in your system documentation) for specific terminal assignments.

Ffigur 3: Gwaelod view of the relay, showing the through-hole connector pins for wiring connections.
- Cyftage Dilysu: Cadarnhewch fod y cyflenwad cyftage for the coil matches the relay's specified voltage o 110-120V AC, 50/60Hz.

Ffigur 4: Agos view of the relay's transparent casing, highlighting the model number and voltage specifications (AC110-120V, 50/60Hz).
- Load Verification: Ensure the connected load does not exceed the relay's contact ratings (e.g., 10A resistive at 240VAC).

Ffigur 5: Ochr view of the relay, displaying detailed electrical ratings and certifications.
- Gwiriad Terfynol: Before restoring power, double-check all connections for security and correctness.
Cyfarwyddiadau Gweithredu
The Idec RH2B-UL-AC110-120V Relay operates automatically based on the control signal applied to its coil. When the specified AC voltage (110-120V) is applied to the coil, the relay contacts will switch, opening or closing the connected load circuit. When the voltage is removed, the contacts return to their original state.
- Ensure the control signal is within the specified voltage range for reliable operation.
- Observe any indicator lights on the relay (if present) to confirm coil energization.
Cynnal a chadw
The Idec RH2B-UL-AC110-120V Relay is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:
- Archwiliad gweledol: Gwiriwch y ras gyfnewid o bryd i'w gilydd am unrhyw arwyddion o ddifrod corfforol, afliwiad, neu gysylltiadau rhydd.
- Glanhau: Os oes angen, glanhewch du allan y ras gyfnewid yn ysgafn gyda lliain sych, meddal. Peidiwch â defnyddio toddyddion na glanhawyr sgraffiniol.
- Contact Inspection: In critical applications, inspect contacts for pitting or wear. Replace the relay if significant wear is observed.
- Amodau Amgylcheddol: Sicrhewch fod yr amgylchedd gweithredu yn aros o fewn yr ystodau tymheredd a lleithder penodedig i atal methiant cynamserol.
Datrys problemau
If the relay is not functioning as expected, consider the following common issues:
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Relay coil does not energize. | No power to coil, incorrect voltage, faulty wiring, or damaged coil. | Check power supply, verify voltage (110-120V AC), inspect wiring connections, test coil continuity. |
| Contacts do not switch. | Coil not energizing, contacts welded, or mechanical failure. | Refer to "Relay coil does not energize" solutions. If coil is good, replace relay. |
| Load not receiving power. | Relay contacts not closing, open circuit in load wiring, or faulty load. | Verify relay operation. Check load circuit wiring and the load itself. |
If troubleshooting steps do not resolve the issue, contact Idec technical support or a qualified electrician.
Manylebau
| Paramedr | Gwerth |
|---|---|
| Rhif Model | RH2B-UL-AC110-120V |
| Brand | Idec |
| Coil Voltage | 110-120V AC |
| Amlder | 50/60 Hz |
| Current Rating (Resistive) | 10A @ 240VAC, 10A @ 30VDC |
| Current Rating (General Use) | 7.5A @ 120VAC, 7A @ 240VAC, 7.5A @ 30VDC |
| Sgôr marchnerth | 1/6 HP @ 120VAC, 1/3 HP @ 240VAC |
| Math Mowntio | Mynydd Rheilffordd DIN |
| Math o Gysylltydd | Trwy Dwll |
| Modd Gweithredu | Awtomatig |
| Pwysau Eitem | 0.01 owns |
| Gwneuthurwr | Idec |
Gwarant a Chefnogaeth
For warranty information and technical support, please contact Idec directly through their official website or customer service channels. Keep your purchase receipt for warranty claims.
Idec Official Websafle: us.idec.com