Rhagymadrodd
Welcome to your APC Back-UPS Pro 1500VA 230V Power Saving Uninterruptible Power Supply. This manual provides essential information for the safe and efficient operation of your UPS, designed to protect your electronic equipment from power outages, surges, and fluctuations. Please read this manual thoroughly before installation and use.
Rhagofalon Diogelwch
- Perygl Sioc Drydanol: Mae'r UPS hwn yn cynnwys cyfaint peryglustagPeidiwch â cheisio dadosod yr uned. Dim ond personél cymwys ddylai wneud y gwaith cynnal a chadw.
- Seiliau priodol: Always connect the UPS to a grounded outlet. Do not remove the grounding prong from the power cord.
- Defnydd Dan Do yn Unig: This product is intended for indoor use only. Do not install the UPS in direct sunlight, near heat sources, or in areas with excessive moisture.
- Awyru: Sicrhewch fod digon o lif aer o amgylch yr UPS. Peidiwch â rhwystro agoriadau awyru.
- Diogelwch Batri: Batteries can present a risk of electrical shock and high short-circuit current. Observe all precautions when replacing batteries. Use only APC-approved replacement batteries (RBC154).
- Diogelu gorlwytho: Peidiwch â gorlwytho'r UPS. Gwnewch yn siŵr nad yw cyfanswm y pŵer a dynnir gan yr offer cysylltiedig yn fwy na chynhwysedd yr UPS.
Cynnwys Pecyn
Gwiriwch fod yr holl eitemau a restrir isod wedi'u cynnwys yn eich pecyn:
- APC Back-UPS Pro 1500VA 230V UPS Unit
- Llawlyfr Defnyddiwr (y ddogfen hon)
- Cord Pŵer
- Cebl Cyfathrebu USB
Cynnyrch Drosview
The APC Back-UPS Pro 1500VA 230V is a tower form factor UPS providing reliable battery backup and surge protection for your critical electronic equipment.
Nodweddion Panel Blaen

Blaen view of the APC Back-UPS Pro 1500VA unit, showing the LCD display and control buttons.
- Arddangosfa LCD: Provides real-time status information including input/output voltage, load level, battery charge, and estimated runtime.
- Botwm Pŵer: Turns the UPS unit on or off.
- Botwm Arddangos: Cycles through various display screens to show different operational parameters.
- Mute/Setup Button: Mutes audible alarms or enters setup mode for configuration.
- USB-A and USB-C Charging Ports: Conveniently located for charging mobile devices.
Nodweddion Panel Cefn

Cefn view of the APC Back-UPS Pro 1500VA unit, showing the power outlets, data ports, and main power input.
- Allfeydd Wrth Gefn Batri a Gwarchodaeth rhag Ymchwydd: Provide power from the battery during outages and protect against surges. Connect critical equipment here.
- Allfeydd Ymchwydd yn Unig: Provide surge protection only. Connect non-critical equipment here.
- Prif Mewnbwn Pŵer: Connects the UPS to the wall outlet.
- Torri Cylchdaith: Provides overload protection for the UPS. Press to reset if tripped.
- Porth Cyfathrebu USB: Connects the UPS to a computer for power management software.
- Ethernet/Network Protection Ports: Protects network connections from surges.
Gosod
- Dadbacio ac Archwilio: Carefully unpack the UPS and all accessories. Inspect for any shipping damage.
- Cysylltu Batri Mewnol: The UPS battery may be disconnected for shipping. Refer to the battery compartment access panel (usually at the bottom or rear) and connect the battery terminals as indicated.
- Position the UPS: Place the UPS in a location with adequate ventilation, away from direct sunlight, excessive heat, or moisture. Ensure the front and rear vents are unobstructed.
- Cysylltu â Wall Outlet: Plug the UPS power cord directly into a grounded 230V wall outlet. Avoid using extension cords or surge protectors with the UPS input.
- Tâl Cychwynnol: Allow the UPS to charge for at least 24 hours before connecting any equipment to ensure maximum battery runtime. The battery indicator on the LCD will show charging status.
- Offer Cyswllt:
- Plug critical equipment (e.g., computer, monitor, router) into the Battery Backup & Surge Protected allfeydd.
- Plug non-critical equipment (e.g., printer, scanner) into the Ymchwydd yn Unig allfeydd.
- Connect Data Lines (Optional): Connect your USB communication cable from the UPS to your computer to enable power management software features. Connect network cables to the Ethernet protection ports if desired.
Cyfarwyddiadau Gweithredu
Troi Ymlaen/Diffodd
- I droi ymlaen: Press and hold the Power button on the front panel until you hear a beep and the LCD display illuminates.
- I'w Diffodd: Press and hold the Power button until the LCD display turns off.
Llywio Arddangos LCD
- Press the Display button repeatedly to cycle through various information screens, including: Input Voltage, Allbwn Voltage, Load in Watts, Load in VA, Battery Charge Percentage, and Estimated Runtime.
Rheoli Larwm
- Yn ystod pŵer chitage, the UPS will emit an audible alarm. Press the Mute/Setup button briefly to temporarily silence the alarm.
- To permanently disable or enable alarms, refer to the detailed instructions in the full user manual or power management software.
Cynnal a chadw
Amnewid Batri
- The typical battery life is 3-5 years, depending on usage and environmental conditions.
- When the battery needs replacement, the UPS will indicate this on the LCD display and may emit an alarm.
- Use only genuine APC replacement battery cartridges (RBC154) to ensure optimal performance and safety. Refer to the full user manual for detailed battery replacement instructions.
Glanhau
- Regularly clean the exterior of the UPS with a dry cloth.
- Ensure ventilation openings are free from dust and debris to prevent overheating.
Storio
- If storing the UPS for an extended period, ensure the battery is fully charged.
- Store the unit in a cool, dry location with adequate ventilation.
- Recharge the battery every 3-6 months to prevent permanent damage.
Datrys problemau
Isod mae problemau cyffredin a'u datrysiadau posibl:
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Ni fydd UPS yn troi ymlaen | Battery disconnected or low charge; UPS not plugged in. | Ensure battery is connected. Plug UPS into a live wall outlet and allow to charge. |
| Amser rhedeg batri byr | Overloaded; battery old or not fully charged. | Reduce connected load. Allow battery to charge for 24 hours. Replace battery if old. |
| UPS emits continuous alarm | On battery mode; overload; battery fault. | Check power source. Reduce load. Check battery status on LCD. |
| Dim pŵer i allfeydd | UPS off; circuit breaker tripped; battery fault. | Turn UPS on. Reset circuit breaker. Check battery status. |
Manylebau Technegol
| Nodwedd | Manyleb |
|---|---|
| Rhif Model | BR1500GI |
| Dimensiynau Cynnyrch | 4.41 x 15.04 x 11.89 modfedd |
| Pwysau Eitem | 27.9 pwys |
| Cyftage | 230 folt |
| Batris | Mae angen 1 batri 12V (wedi'u cynnwys) |
| Cyfansoddiad Cell Batri | Asid Plwm |
| Lliw | Du |
| Deunydd | Metel |
| Ffactor Ffurf | Twr |
Gwarant a Chefnogaeth
For detailed warranty information, product registration, and technical support, please visit the official APC by Schneider Electric websafle neu cysylltwch â'u hadran gwasanaeth cwsmeriaid. Cadwch eich derbynneb prynu fel prawf o brynu ar gyfer unrhyw hawliadau gwarant.
Gallwch ddod o hyd i adnoddau ychwanegol a gwybodaeth gyswllt yn Siop APC gan Schneider Electric ar Amazon.