APC AP7921

APC AP7921 Switched Rack PDU User Manual

Model: AP7921

1. Rhagymadrodd a Throsoddview

The APC AP7921 is a Switched Rack Power Distribution Unit (PDU) designed for efficient power management in rack environments. This 1U horizontal mounting PDU provides eight (8) C13 output receptacles and accepts a 208V-230V input via an IEC-320 C20 connector, supporting a 16A single-phase load. It offers advanced features such as remote individual outlet control, local current monitoring, and remote management capabilities, making it suitable for critical IT infrastructure.

APC AP7921 Switched Rack PDU front view with 8 C13 outlets and display

Ffigur 1.1: Blaen view of the APC AP7921 Switched Rack PDU, showing the eight C13 output receptacles and the local current monitoring display.

Nodweddion Allweddol:

2. Gwybodaeth Diogelwch

Read and understand all instructions before installing or operating this equipment. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Cynnwys Pecyn

Verify that all components are present upon unpacking. If any items are missing or damaged, contact your vendor or APC support.

4. Gosod a Gosod

4.1 Mowntio rac

  1. Identify a 1U (1.75 inches) space in your standard 19-inch server rack.
  2. Attach the provided mounting brackets to the sides of the PDU using the included screws.
  3. Secure the PDU into the rack using appropriate rack screws, ensuring it is firmly seated.

4.2 Cysylltiad Pwer

  1. Connect the IEC-320 C20 input connector of the PDU to a compatible 208V-230V, 16A power source. Ensure the power source is properly grounded and capable of supplying the required current.
  2. Connect your IT equipment's power cords to the eight (8) C13 output receptacles on the PDU. Distribute the load evenly across the outlets if possible.

5. Gweithrediad

5.1 Pweru Ymlaen

Once the PDU is connected to a power source, it will power on automatically. The local current monitoring display will illuminate, showing the total current draw.

5.2 Local Current Monitoring

The integrated display on the front panel provides real-time information on the total current being drawn by all connected devices. This helps in preventing overloads and managing power capacity.

5.3 Remote Individual Outlet Control

The AP7921 allows for remote control of each individual C13 outlet. This feature enables users to power cycle, turn on, or turn off connected equipment remotely, which is beneficial for troubleshooting or managing power to specific devices without physical access.

5.4 Power Delays

The PDU supports configurable power-on and power-off delays for its outlets. This feature helps in sequencing the startup of equipment to prevent inrush current overloads and manage system dependencies.

6. Cyfluniad

The AP7921 PDU offers various configuration options through its network interface for remote management.

6.1 Mynediad Rhwydwaith

Connect the PDU to your network using an Ethernet cable. Access the PDU's web interface via its assigned IP address to configure settings, monitor status, and control outlets. Refer to the network configuration guide for initial setup.

6.2 Alarm Thresholds

Configure alarm thresholds for current draw. The PDU can send alerts via email or SNMP traps if the current exceeds or falls below specified limits, helping to prevent overloads or identify power issues.

6.3 Diweddariadau Firmware

The PDU's firmware is flash upgradeable. Regularly check the APC website for the latest firmware versions to ensure optimal performance and access to new features. Follow the provided instructions for firmware upgrade procedures.

7. cynnal

7.1 Glanhau

Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents. Ensure the PDU is disconnected from the power source before cleaning.

7.2 Ystyriaethau Amgylcheddol

Ensure the PDU operates within its specified temperature and humidity ranges. Maintain proper airflow around the unit to prevent overheating.

8. Datrys Problemau

8.1 No Power to Outlets

8.2 Overload Indication

8.3 Problemau Mynediad o Bell

9. manylebau

NodweddManyleb
Rhif ModelAP7921
Mewnbwn Voltage208V-230V
Cyfredol Mewnbwn16A
Connector MewnbwnIEC-320 C20
Derbynyddion Allbwn8 x IEC-320 C13
Ffactor Ffurf1U Horizontal Rack-Mountable
Dimensiynau Cynnyrch (H x W x D)2.7 x 18.5 x 13.5 modfedd (tua)
Pwysau Eitem1.54 pwys
Hyd Cord7.8 modfedd
Nodwedd ArbennigMountable, Switched Outlets, Remote Management
GwneuthurwrAPC

10. Gwarant a Chefnogaeth

For warranty information, technical support, or service inquiries, please refer to the official APC website or contact your local APC representative. Ensure you have your product model number (AP7921) and serial number available when contacting support.

Adnoddau Ar-lein: Ymwelwch www.apc.com for product documentation, software downloads, and support contact information.

Dogfennau Cysylltiedig - AP7921

Cynview APC Switched Rack Power Distribution Unit Installation Guide
Installation and operation guide for APC Switched Rack Power Distribution Units (PDUs), covering features, installation, configuration, access, warranty, and support.
Cynview APC Easy PDU Metered-by-Outlet Rack Power Distribution Unit Installation Guide
Installation guide for APC Easy PDU Metered-by-Outlet Rack Power Distribution Units (EPDU2116MBO, EPDU2132MBO, EPDU2216MBO, EPDU2232MBO), covering safety, installation, display interface, and specifications.
Cynview Canllaw Gosod Amnewid PDU APC SMT2200/SMT3000 | Schneider Electric
Mae'r canllaw hwn yn darparu cyfarwyddiadau ar gyfer gosod panel PDU dewisol ar gyfer systemau UPS APC SMT2200 ac SMT3000. Mae'n cynnwys negeseuon diogelwch pwysig, canllawiau trin cynnyrch, a gweithdrefnau gosod cam wrth gam.
Cynview Canllaw Cynnyrch Systemau Uwch a Rac PDU APC NetShelter Rack
Canllaw cynhwysfawr i PDUs Rac APC NetShelter, gan gynnwys y modelau allfa 4-mewn-1 uwch, opsiynau sylfaenol, mesuredig, wedi'u switsio, a mesuredig-wrth-allfa ar gyfer rheoli pŵer canolfan ddata. Nodweddion manylebau, ategolion, ac atebion system rac.
Cynview Canllaw Gosod Uned Dosbarthu Pŵer Rack APC
Installation instructions for APC Rack Power Distribution Units (PDUs), including safety precautions, mounting procedures, and display interface information.
Cynview Llawlyfr Gosod a Defnyddiwr APC NetShelter AR1000, AR1001, AR1100
Mae'r llawlyfr hwn yn darparu cyfarwyddiadau manwl ar gyfer gosod, sefydlu a chynnal a chadw raciau NetShelter American Power Conversion (APC), gan gynnwys modelau AR1000, AR1001, ac AR1100. Mae'n cwmpasu rhestr eiddo cynnyrch, rhybuddion, ffurfweddiad, lefelu, sefydlogi, a gwybodaeth am warant.