FeelTech ZT-DQ01
FeelTech ZT-DQ01 Handheld Digital LCR Meter Instruction Manual
Model: ZT-DQ01
Brand: FeelTech
1. Rhagymadrodd
This manual provides detailed instructions for the safe and effective use of the FeelTech ZT-DQ01 Handheld Digital LCR Meter. Please read this manual thoroughly before operation.
The ZT-DQ01 is a high-precision handheld digital bridge LCR meter designed for measuring capacitance, resistance, and inductance. It features a 2.8-inch full-view angle color screen and supports true four-wire measurement.

Image 1: FeelTech ZT-DQ01 LCR Meter and included accessories.
2. Nodweddion Allweddol
- Handheld digital high-precision bridge tester for LCR measurement.
- Measures resistance, capacitance, and inductance with true four-wire L/C/R/Z value display.
- Equipped with a 2.8-inch full-view angle color screen.
- Automatic identification of resistors, capacitors, and inductors.
- Features an adjustable auto power-off function for energy saving; compact and portable design.

Delwedd 2: Drosoddview of the ZT-DQ01's main features, including true four-wire measurement and L/C/R/Z value display.
3. Gosod a Defnydd Cychwynnol
3.1 Dadbacio
Carefully unpack the ZT-DQ01 LCR Meter and all accessories. Verify that all components listed in the "What's in the Box" section are present:
- ZT-DQ01 LCR Meter
- Arweinwyr prawf
- Cebl gwefru USB Math-C
- Cwdyn cario
3.2 Codi Tâl ar y Dyfais
The ZT-DQ01 is powered by a 400mA lithium battery. Before first use, fully charge the device using the provided USB Type-C cable and a compatible USB power adapter (not included).

Image 3: The 2.8-inch color screen and Type-C charging port of the ZT-DQ01.
3.3 Cysylltu Gwifrau Prawf
Connect the provided test leads to the appropriate input terminals on the LCR meter. Ensure a secure connection for accurate measurements. The meter supports true four-wire measurement for enhanced precision.

Image 4: The ZT-DQ01 LCR Meter connected to a component for testing, demonstrating automatic identification.
4. Cyfarwyddiadau Gweithredu
4.1 Pŵer Ymlaen/Diffodd
Pwyswch a dal y botwm pŵer (ⓘ) i droi'r ddyfais ymlaen neu i ffwrdd.
4.2 Mesur Sylfaenol
The ZT-DQ01 features automatic identification of resistors, capacitors, and inductors. Simply connect the component to the test leads, and the meter will automatically detect the component type and display the relevant parameters (L, C, R, Z, X, D, Q, θ, ESR).
4.3 Botymau Swyddogaeth
- FREQ: Adjusts the test frequency (100Hz, 120Hz, 1KHz, 10KHz, 100KHz).
- LEFEL: Sets the test level (0.1V, 0.3V, 0.6V).
- CYFLYMDER: Adjusts the measurement speed (Slow, Medium, Fast).
- X/D/Q/θ/ESR: Cycles through displayed sub-parameters.
- AUTO/S/P SETUP: Automatic series/parallel mode setup.
- LCRZ: Selects the main measurement parameter (Inductance, Capacitance, Resistance, Impedance).
- HOLD/REC: Holds the current measurement or enters record mode.
- REL TOL%: Relative measurement and tolerance percentage.
4.4 Discharging Capacitors
WARNING: Always discharge capacitors before testing to prevent damage to the meter or injury.

Delwedd 5: Manwl view of the ZT-DQ01's control panel and display, illustrating various functions.
5. cynnal
5.1 Glanhau
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the device is powered off before cleaning.
5.2 Storio
Store the LCR meter in a cool, dry place, away from direct sunlight and extreme temperatures. Use the provided carrying pouch for protection.
5.3 Graddnodi
The ZT-DQ01 supports bridge calibration for short circuit and open circuit. Refer to the on-screen menu for calibration procedures to maintain measurement accuracy.
6. Datrys Problemau
- Dim pŵer: Ensure the battery is charged. Connect the USB Type-C cable to charge.
- Darlleniadau Anghywir:
- Check test lead connections.
- Perform bridge calibration (short circuit, open circuit).
- Ensure the component is properly discharged before testing.
- Verify correct test frequency and level settings.
- Problemau Arddangos: Adjust backlight brightness if the screen is too dim or bright.
7. Manylebau Technegol
| Paramedr | Gwerth/Amrediad |
|---|---|
| Rhif Model | ZT-DQ01 |
| Arddangos | 2.8 modfedd yn llawn view angle color screen |
| Paramedrau Mesur | L, C, R, Z, X, D, Q, θ, ESR |
| Ystod Gwrthsefyll | 0Ω - 20MΩ |
| Ystod Cynhwysedd | 0pF - 100mF |
| Ystod Anwythiant | 0nH - 100H |
| Amlderau Prawf | 100Hz, 120Hz, 1KHz, 10KHz, 100KHz |
| Lefelau Prawf | 0.1V, 0.3V, 0.6V |
| Cywirdeb | Hyd at 0.3% |
| Batri | Batri Lithiwm 400mA |
| Rhyngwyneb Codi Tâl | USB Math-C |
| Dimensiynau | 146 x 30 x 18 mm |
| Pwysau | 1 cilogram (tua 2.2 pwys) |
| Ardystiadau | CE, RoHS |

Image 6: Detailed technical specifications table for the ZT-DQ01 LCR Meter.
8. Ceisiadau
The FeelTech ZT-DQ01 LCR Meter is suitable for a wide range of applications, including:
- Cynnal a Chadw Offer
- Scientific Research and Education
- Profi Cynhyrchu
- Electronic Engineering Development

Image 7: Illustrates various applications of the ZT-DQ01 LCR Meter in different fields.
9. Gwarant a Chefnogaeth
This product comes with a standard manufacturer's warranty. For warranty claims or technical support, please contact your retailer or the manufacturer directly. Please refer to your purchase documentation for specific warranty terms and contact information.
Hyd Argaeledd Rhannau Sbâr yr UE: 1 Flwyddyn.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.