This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your Skyking Beetech B-6020 Digital Clamp Meter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent potential hazards.

Gwybodaeth Diogelwch

Always adhere to basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, or personal injury. Keep this manual for future reference.

  • Do not exceed the maximum input limits specified for each function.
  • Ensure the test leads are in good condition and properly connected before making measurements.
  • Do not use the meter if it appears damaged or if the case is open.
  • Byddwch yn ofalus iawn wrth weithio gyda chylchedau byw.
  • Datgysylltwch y pŵer i'r gylched bob amser a rhyddhewch yr holl foltedd ucheltage cynwysorau cyn profi gwrthiant, parhad, deuodau, neu gynhwysedd.
  • Amnewidiwch y batris ar unwaith pan fydd y dangosydd batri isel yn ymddangos.
  • Peidiwch â gweithredu'r mesurydd mewn amgylcheddau nwy, anwedd neu lwch ffrwydrol.

Cynnwys Pecyn

Verify that all items listed below are present and undamaged upon opening the package:

  • Beetech B-6020 Digital Clamp Mesurydd
  • Gwifrau Prawf (Coch a Du)
  • Archwiliwr Tymheredd
  • Batris AAA (2 wedi'u cynnwys)
  • Protective Black Cover / Carrying Case
  • Llawlyfr Cyfarwyddiadau (y ddogfen hon)
Beetech B-6020 Digital Clamp Meter with test leads and temperature probe in a black carrying case.

Image: The Beetech B-6020 Digital Clamp Meter, its test leads, and temperature probe neatly arranged within its protective black carrying case.

Cynnyrch Drosview

Familiarize yourself with the components and display features of the Beetech B-6020 Digital Clamp Mesurydd.

Diagram of Beetech B-6020 Digital Clamp Meter highlighting NCV Sensor Probe, Clamp, Trigger, Clamp Corff Lamp, Range Switch, Backlight, HOLD & Flashlight, SEL button, Warning Light, LCD Display, Input Terminal, and COM Terminal.

Image: A diagram illustrating the key components of the Beetech B-6020 Clamp Meter, including the NCV sensor, clamp, trigger, display, and various function buttons.

Nodweddion Allweddol:

  • Mesuriad Cerrynt AC/DC 600A: For measuring alternating and direct current up to 600 Amperes.
  • 600V AC/DC Voltage Mesur: For measuring alternating and direct voltage hyd at 600 folt.
  • Arddangosfa LCD fawr: 6000 Count, 3 5/6 Digits with Backlight for clear readings in various lighting conditions.
  • Mesur Tymheredd: Utilizes the included temperature probe.
  • Mesur Amlder: For determining the frequency of AC signals.
  • Mesur Gwrthiant: For measuring electrical resistance.
  • Mesur Cynhwysedd: For measuring capacitance values.
  • Prawf Deuod: For checking diode functionality.
  • Prawf Parhad: Audible indication for circuit continuity.
  • Flashlight: Integrated for illuminating work areas.
  • Swyddogaeth Dal Data: To freeze the displayed reading.
  • Cyf. Di-gyswllttagCanfod e (NCV): Ar gyfer canfod AC cyftage heb gysylltiad uniongyrchol.
  • Golau Rhybudd: Visual indicator for certain conditions.

Gosod

Gosod Batri:

  1. Lleolwch glawr adran y batri ar gefn y mesurydd.
  2. Defnyddiwch sgriwdreifer i agor y compartment batri.
  3. Insert the two AAA batteries, observing the correct polarity (+ and -).
  4. Amnewid gorchudd adran y batri a'i ddiogelu gyda'r sgriw.

Cysylltu Gwifrau Prawf:

Ar gyfer cyftage, resistance, continuity, diode, capacitance, and temperature measurements, connect the test leads as follows:

  • Insert the red test lead into the "VΩHz" input terminal.
  • Insert the black test lead into the "COM" (common) input terminal.
  • For temperature measurements, connect the temperature probe to the appropriate terminals as indicated on the meter or in the specific operating section.

Cyfarwyddiadau Gweithredu

Turn the rotary switch to the desired function. The meter will automatically select the appropriate range for most measurements (auto-ranging). Use the "SEL" button to switch between functions within a single rotary switch position (e.g., AC/DC voltage, resistance/diode/continuity).

1. AC/DC Current Measurement (Clamp Function):

  1. Rotate the switch to the "600A AC/DC" position.
  2. Pwyswch y sbardun i agor y clamp enau.
  3. Enclose only one conductor (wire) within the clamp jaws. Ensure the jaws are fully closed.
  4. Read the current value on the display. Use the "SEL" button to switch between AC and DC current if necessary.

2. AC / DC Voltage Mesur:

  1. Connect the test leads as described in the "Connecting Test Leads" section.
  2. Rotate the switch to the "V" position.
  3. Use the "SEL" button to select between AC (~) and DC (---) voltage.
  4. Touch the test probes to the circuit points where voltage sydd i'w fesur.
  5. Darllenwch y cyftage gwerth ar yr arddangosfa.

3. Mesur Gwrthiant:

  1. Gwnewch yn siŵr bod y gylched wedi'i dad-egnïo cyn mesur gwrthiant.
  2. Connect the test leads.
  3. Rotate the switch to the "Ω" position.
  4. Touch the test probes across the component or circuit to be measured.
  5. Darllenwch y gwerth gwrthiant ar yr arddangosfa.

4. Prawf Parhad:

  1. Gwnewch yn siŵr bod y gylched wedi'i dad-egni.
  2. Connect the test leads.
  3. Rotate the switch to the "Ω" position and press "SEL" until the continuity symbol (speaker icon) appears.
  4. Touch the test probes across the circuit or component. An audible beep indicates continuity (low resistance).

5. Prawf Deuod:

  1. Gwnewch yn siŵr bod y gylched wedi'i dad-egni.
  2. Connect the test leads.
  3. Rotate the switch to the "Ω" position and press "SEL" until the diode symbol appears.
  4. Touch the red probe to the anode and the black probe to the cathode of the diode. A forward voltage drop will be displayed. Reverse the probes; an open circuit (OL) should be displayed.

6. Capacitance Measurement:

  1. Gwnewch yn siŵr bod y cynhwysydd wedi'i ryddhau'n llwyr cyn mesur.
  2. Connect the test leads.
  3. Rotate the switch to the "Capacitance" position (often shared with other functions, use "SEL" to select).
  4. Touch the test probes to the capacitor terminals.
  5. Darllenwch y gwerth cynhwysedd ar yr arddangosfa.

7. Mesur Tymheredd:

  1. Connect the temperature probe to the input terminals (usually VΩHz and COM, or dedicated temperature inputs if available).
  2. Rotate the switch to the "°C/°F" position.
  3. Use the "SEL" button to switch between Celsius and Fahrenheit.
  4. Place the tip of the temperature probe on the object or in the environment to be measured.
  5. Darllenwch werth y tymheredd ar yr arddangosfa.

8. Mesur Amlder:

  1. Connect the test leads.
  2. Rotate the switch to the "Hz" position (often shared with voltage or current, use "SEL" to select).
  3. Touch the test probes to the circuit where frequency is to be measured.
  4. Darllenwch y gwerth amledd ar yr arddangosfa.

9. Di-gyswllt VoltagCanfod e (NCV):

  1. Rotate the switch to the "NCV" position.
  2. Symudwch y synhwyrydd NCV (wedi'i leoli ar frig y clamp meter) close to the conductor or outlet.
  3. The meter will emit an audible beep and/or a warning light will illuminate when AC voltage yn cael ei ganfod.

10. Fflacholau:

Press the "HOLD/Flashlight" button briefly to turn the flashlight on or off. This is useful for illuminating dark work areas.

11. Cadw Data:

Press and hold the "HOLD/Flashlight" button to activate the data hold function. The current reading will be frozen on the display. Press again to release.

Cynnal a chadw

Glanhau:

Sychwch gas y mesurydd gyda hysbysebamp lliain a glanedydd ysgafn. Peidiwch â defnyddio sgraffinyddion na thoddyddion. Gwnewch yn siŵr bod y mesurydd yn hollol sych cyn ei ddefnyddio.

Amnewid Batri:

When the low battery indicator appears on the display, replace the batteries immediately to ensure accurate readings. Refer to the "Battery Installation" section under Setup for instructions.

Storio:

If the meter is not used for an extended period, remove the batteries to prevent leakage. Store the meter in its protective case in a cool, dry place, away from direct sunlight and extreme temperatures.

Datrys problemau

Problem Achos Posibl Ateb
Nid yw'r mesurydd yn troi ymlaen. Batris marw neu wedi'u gosod yn anghywir. Gwiriwch bolaredd y batri; ailosodwch y batris.
"OL" (Gorlwytho) yn cael ei arddangos. Input value exceeds the meter's range. Ensure the measurement is within the specified limits.
Darlleniadau anghywir. Low battery, damaged test leads, or incorrect function selected. Replace batteries, inspect test leads, verify correct function and range.
Dim bîp parhad. Mae'r gylched ar agor, neu nid yw'r swyddogaeth barhad wedi'i dewis. Ensure circuit is closed; select continuity function.

Manylebau

Paramedr Gwerth
Rhif Model Beetech B-6020
Brand Skyking
Gwneuthurwr BEETECH
AC / DC Cyfredol 600A
AC / DC Voltage 600V
Cyfrif Arddangos 6000 Count, 3 5/6 Digits
Nodweddion TRMS, Temperature, Frequency, Resistance, Capacitance, Diode, Continuity, Flash Light, Hold, Backlight, Warning Light, NCV
Batris 2 batris AAA (wedi'u cynnwys)
Pwysau Eitem 380 g
Dimensiynau Cynnyrch (LxWxH) 23 x 5 x 5 centimetr
Cydrannau wedi'u Cynnwys Meter, Test Leads, Temp. Probe, Battery, Manual
Gwlad Tarddiad India
Sgôr Diogelwch CAT III 600V
Beetech B-6020 Digital Clamp Meter packaging highlighting key specifications like 600A AC/DC, 600V AC/DC, 6000 counts, TRMS, NCV, Temperature, Hz, Ohm, Continuity Check, Diode Test, and Overload Protection.

Image: The product packaging displaying key specifications and features of the Beetech B-6020 Clamp Mesurydd.

Gwybodaeth Gwarant

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. The warranty period and terms may vary. Please retain your purchase receipt as proof of purchase. For specific warranty details, please contact Skyking Instruments directly.

Cefnogaeth

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Skyking Instruments customer support. Contact details can typically be found on the product packaging or the official Skyking Instruments websafle.

Manufacturer: BEETECH

Packer: Skyking Instruments, Mumbai, INDIA

© 2025 Skyking Instruments. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.