1. Rhagymadrodd
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of your Garvee 18,000 BTU Mini Split Air Conditioner with Heat Pump, 19 SEER2. Please read this manual thoroughly before installation and use to ensure safe and efficient operation. Keep this manual for future reference.
The Garvee Mini Split Air Conditioner offers:
- Fast Cooling Capability: Engineered for rapid cooling, effectively covering spaces up to 1,250 square feet.
- Ideal for Home Offices: Maintains a comfortable working temperature to enhance focus and efficiency.
- Smart and User-Friendly Operation: Operates within a temperature range of 61℉ to 88℉ with easy adjustments via remote control, including fan speed and sleep mode.
- Ultra Quiet Performance: Operates at noise levels between 27-42 dBa, suitable for bedrooms and quiet spaces.
- Versatile Home Cooling Solution: Adapts to various rooms and usage scenarios for customized comfort.
2. Gwybodaeth Diogelwch
Pwysig: Installation and servicing of this air conditioner must be performed by qualified personnel. Improper installation or servicing can result in electric shock, fire, or water leakage. Always follow local electrical codes and safety regulations.
- Gwnewch yn siŵr bod y cyflenwad pŵer wedi'i ddatgysylltu cyn unrhyw osod neu gynnal a chadw.
- Wear appropriate personal protective equipment (PPE), including safety glasses, gloves, and a hard hat when working at heights.
- Do not install the unit near heat sources, steam sources, or in areas with flammable or explosive gases.
- Sicrhewch sylfaen gywir i atal sioc drydanol.
- Keep the area around the indoor and outdoor units free from obstructions to ensure proper airflow.
3. Cynnwys Pecyn
Gwiriwch fod yr holl gydrannau yn bresennol ac yn ddi-ddifrod cyn bwrw ymlaen â'r gosodiad:
- Uned Dan Do
- Uned Awyr Agored
- Rheolaeth Anghysbell
- Installation Kit (including copper tubing, drain hose, electrical wiring)
- Mounting Plate for Indoor Unit
- Outdoor Unit Brackets
- Llawlyfr Defnyddiwr
Note: Additional tools and materials for installation are listed in the Installation section.
4. Gosod
4.1. Offer a Deunyddiau Angenrheidiol
The following tools and materials are required for proper installation:
- Gwelodd twll
- Amlfesurydd
- Torrwr pibell
- wrenches hecs
- Refrigerant (R410A or R32, depending on unit specifications)
- Wrench torque
- Wrench gymwysadwy
- Mesur tâp
- Mesurydd pwysau
- Safety Belt (for outdoor unit installation at height)
- Teclyn fflachio
- Bracket (for outdoor unit)
- Lefel
- Phillips sgriwdreifer
- Electroprobe
- Pwmp gwactod
- gefail
- Copper tube (if not pre-charged or included)
4.2. Paratoi Cyn Gosod
Before beginning installation, ensure the environment meets the following criteria:
- No heat source or steam source nearby.
- No obstructions around the inlet and outlet of both indoor and outdoor units.
- No flammable or explosive gas, or corrosive gas present.
The wall for the indoor unit should be hard, flat, and firm to avoid vibration and noise.
Indoor Unit Position Requirements:
- To ceiling: > 15cm
- To obstacle (sides): > 20cm
- To floor: 230~260cm
4.3. Indoor Unit Installation Steps
- Fix Mounting Plate:
Put the mounting plate on the wall and use a level to ensure it is horizontal. Select the position for screws, using no less than 5 screws. Punch holes in the wall. Use expansion screw kits to firmly fix the plate to the wall. Note: Do not use nails to fix the plate.
Image: A worker installing the indoor unit mounting plate on a wall, ensuring it is level and secured with screws.
- Twll Wal Dril:
After determining where the pipe will go through the wall, drill a wall hole. Notes: When drilling holes, make sure to avoid wires, plumbing, gas, and other sensitive components. The wall hole should be inclined outward by 5-10 degrees, with a diameter of 60-80mm. Use an anti-dust bag to avoid dust when drilling the hole.Video: A technician drilling a hole in a wall for the refrigerant piping, demonstrating the use of a dust bag and proper angle.
- Installation of Connection Cable:
Pass the power cable out from the back of the indoor unit and fix it on the terminal board. Fix the cable with a clamp. Note: Must follow the wiring diagram inside the box cover. - Knock-out Panel:
According to the piping direction, remove the knock-out panel with a knife, and remove burrs to prevent the drain pipe from being broken. - Connection of Refrigerant Piping:
Use both hands to turn the pipe in the desired direction. Note: It is forbidden to operate with one hand, which will make the tube to deform and rupture. Aim at the pipe center, tighten the taper nut with fingers, then tighten the taper nut with 2 wrenches. Note: It's better to use a torque wrench to tighten the taper nut, the required torque is shown in the picture.Torque Specifications for Taper Nuts Size of pipe (mm) Torque (Nm) Φ6/Φ6.35 15-25 Φ9/Φ9.52 35-40 Φ12/Φ12.7 45-60 Φ15.88 73-78 Φ19.05 75-80 - Install the Drain Hose:
Connect the drain hose with the water outlet pipe, and fix it firmly with adhesive tape. The length should be more than 5cm to prevent water leakage. - Wrap the Piping:
Wrap refrigerant piping, wires, and drain pipe with wrapping tape. - Uned Dan Do Mowntio:
Put the refrigerant piping out of the wall hole. Put the indoor unit on the mounting plate. Push the lower part of the indoor unit until a 'click' sound is heard to make sure the indoor unit is firmly fixed to the wall. To protect piping and wires, a pipe protecting ring shall be installed sealed with putty.
4.4. Outdoor Unit Installation Steps
Outdoor Unit Position Requirements:
- Outdoor unit must be installed in a firm and flat place to prevent vibration and noise.
- To the obstruction (top): > 20cm
- To the obstruction (sides): > 30cm
- Air in side: > 10cm
- Air out side: > 200cm
If installing the air conditioner to a higher place, the operator should wear a safety belt and helmet.
- Install Outdoor Unit Bracket:
Use a level to ensure the bracket is horizontal and vertical. Use at least 6 expansion bolts to make sure brackets are fixed firmly on the wall. - Fix Outdoor Unit:
Put the outdoor unit onto the brackets. Use 4 screws to fix the feet of the outdoor unit. - Connect Refrigerant Piping:
Remove the nut from the stop valves. Aim at the pipe center of the stop valve, tighten the taper nut with fingers. Tighten the taper nut with 2 wrenches. Note: It's better to use a torque wrench to tighten the taper nut, the required torque is shown in the table above. - Vacuumize:
Connect the stop valve, charging hose, manifold valve, and vacuum pump as shown in the diagram. Before vacuuming, check all the nuts of the indoor and outdoor unit are tightened. Turn on handle Lo to vacuumize. Vacuumize for 15 minutes at least, make sure the value on the pressure gauge is ≤0.1MPa. Pressure keep for 3-5 minutes after vacuumizing, make sure pressure springback ≤0.05MPa. Open 1/4 liquid valve, and remove charging hose. Open all the liquid valves and gas valves. Screw all the caps and tighten up. - Fix Cables:
Remove the electrical box cover. Fix cables to the terminal board according to the wiring diagram on the E-parts cover. Use a clamp to fix the cables. Put the electrical box cover back.
5. Cyfarwyddiadau Gweithredu
Your Garvee Mini Split AC unit can be operated using the included remote control or a compatible smart app. Familiarize yourself with the remote control functions for optimal use.
5.1. Swyddogaethau Sylfaenol
- Pŵer ymlaen / i ffwrdd: Pwyswch y botwm pŵer ar y teclyn rheoli o bell.
- Dewis Modd: Cycle through modes (Cool, Heat, Fan, Dry) using the Mode button.
- Addasiad Tymheredd: Use the Up/Down arrows to set your desired temperature (61℉ to 88℉).
- Cyflymder Fan: Adjust fan speed (Auto, Low, Medium, High) to your preference.
5.2. Nodweddion Uwch
- Modd Cwsg: Yn optimeiddio tymheredd a chyflymder ffan ar gyfer cwsg cyfforddus ac arbed ynni.
- Swyddogaeth Amserydd: Set the unit to turn on or off automatically at specific times.
- Swyddogaeth swing: Adjust the airflow direction for even distribution.

Image: A hand holding a remote control for the AC unit, with an illustration of a smartphone app, indicating multiple control methods.
6. cynnal
Mae cynnal a chadw rheolaidd yn sicrhau perfformiad a hirhoedledd gorau posibl eich cyflyrydd aer.
6.1. Glanhau Hidlo
The air filters should be cleaned regularly, typically every two weeks, or more often if the unit is used frequently or in dusty environments.
- Diffoddwch y cyflenwad pŵer i'r uned.
- Agorwch banel blaen yr uned dan do.
- Tynnwch yr hidlyddion aer.
- Glanhewch y hidlwyr gyda sugnwr llwch neu golchwch nhw â dŵr llugoer.
- Gadewch i'r hidlwyr sychu'n llwyr cyn eu hailosod.
- Caewch y panel blaen.

Image: A man removing and cleaning the air filter of an indoor AC unit, illustrating the filter cleaning reminder feature.
6.2. Self-Cleaning & Sterilization
This unit features a 56℃ high-temperature self-cleaning and sterilization function to ensure fresh and clean air.

Image: An AC unit with icons representing frosting, defrosting, high-temperature drying, and 56℃ high-temperature sterilization features.
7. Datrys Problemau
If you encounter issues with your air conditioner, refer to the following common problems and solutions. If the problem persists, contact qualified service personnel.
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw'r uned yn troi ymlaen | Dim cyflenwad pŵer; Batris teclyn rheoli o bell wedi marw | Check power connection and circuit breaker; Replace remote control batteries |
| Oeri/gwresogi annigonol | Dirty air filters; Blocked outdoor unit; Incorrect mode setting; Room size exceeds capacity | Clean air filters; Clear obstructions from outdoor unit; Select correct mode; Ensure unit matches room size |
| Swn anarferol | Rhannau rhydd; Uned heb fod yn lefel; Rhwystr yn y ffan | Check for loose screws; Ensure unit is level; Remove any obstructions |
| Gollyngiad dŵr o'r uned dan do | Clogged drain hose; Improperly installed drain hose | Clear drain hose; Ensure drain hose is sloped correctly and securely connected |
| Rheolaeth bell ddim yn gweithio | Batteries dead; Obstruction between remote and unit; Remote sensor blocked | Replace batteries; Remove obstructions; Clean remote sensor area |
8. manylebau
| Nodwedd | Manylyn |
|---|---|
| Dimensiynau Cynnyrch | 37.01 x 24.25 x 30.67 modfedd |
| Pwysau Eitem | 104.6 pwys |
| Gwneuthurwr | Garvee |
| ASIN | B0F489283Z |
| Rhif model yr eitem | 49wDhS_yXcLoAb9PUhN4yAKJS2O7H |
| Gallu | 67.5 Peint |
| Cyftage | 230 |
| Lefel Sŵn | 56 Desibel |
| Pŵer Oeri | 18000 o Unedau Thermol Prydain |
| Nodwedd Arbennig | Oeri Cyflym |
| Lliw | Gwyn |
| Enw Model | HJ5CESWK0 |

Image: Diagram showing the dimensions of the indoor and outdoor units of the Garvee Mini Split AC.
9. Gwarant a Chefnogaeth