FireAngel SW1-R

FireAngel SW1-R Mains Powered Optical Smoke Alarm User Manual

Model: SW1-R

1. Cynnyrch Drosview

The FireAngel SW1-R is a mains-powered optical smoke alarm designed to provide early warning of fire. It features a 9V backup battery to ensure continuous protection during power outages. The alarm emits a loud 85dB sound at 3 meters and includes LED visual indicators for clear alerts.

This optical smoke alarm is particularly effective at detecting slow-burning fires that produce thick white smoke, making it suitable for general living areas.

Nodweddion Allweddol:

  • Mains Powered with 9V Battery Backup: Ensures continuous operation even during power failures.
  • Optical Smoke Sensor: Detects slow-burning fires and reduces false alarms.
  • Interlink Capability: Can be hardwired and interconnected with up to 12 compatible FireAngel smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms.
  • Botwm Prawf/Distawrwydd: Allows for easy testing of the alarm and temporary silencing of false alarms.
  • Loud 85dB Alarm: Provides clear audible warning.
  • Dangosyddion LED: Visual alerts for alarm status.
  • Sleep Easy Function: Temporarily silences low battery chirps for up to 8 hours.
  • Ardystiedig: Meets British Safety Standard EN 14604: 2005.
FireAngel SW1-R Smoke Alarm front view

Ffigur 1: Blaen view of the FireAngel SW1-R Mains Powered Optical Smoke Alarm.

FireAngel SW1-R Smoke Alarm with packaging and key features

Figure 2: FireAngel SW1-R Smoke Alarm highlighting its 9V backup battery, audible/visual alerts, and large test button.

2. Gwybodaeth Bwysig am Ddiogelwch

Please read all instructions carefully before installation and operation. Keep this manual for future reference.

  • Diogelwch Trydanol: Installation must be carried out by a qualified electrician in accordance with local wiring regulations. Always disconnect the mains electricity supply before installation or maintenance.
  • Lleoliad: Smoke alarms should be sited at least 300 mm (12 inches) from light fittings and walls.
  • Avoidance Areas: This smoke alarm is ddim yn addas for installation in kitchens, bathrooms, garages, or areas with high humidity, dust, or extreme temperatures, as these conditions can lead to false alarms.
  • Peidiwch â phaentio: Never paint the smoke alarm. Paint can block the smoke entry points and interfere with the sensor's operation.
  • No Cleaners: Do not use cleaning agents or solvents on the device. Wipe with a dry cloth only.
  • Rhwystrau: Ensure the alarm is not obstructed by furniture, curtains, or other objects that could prevent smoke from reaching the sensor.
  • Profi Rheolaidd: Test the alarm monthly to ensure proper function.
FireAngel SW1-R Smoke Alarm placement guidelines

Figure 3: Illustration of recommended placement guidelines for the smoke alarm, showing distance from walls and light fittings, and unsuitable locations.

3. Cynnwys Pecyn

Gwiriwch fod yr holl eitemau yn bresennol ac yn ddi-ddifrod wrth agor y pecyn:

  • 1x FireAngel SW1-R Smoke Alarm Unit
  • Plât Sylfaen 1x
  • 1x 9V Battery (for backup)
  • Sgriwiau 2x
  • 2x Rawl Plugs
  • 1x Llawlyfr Cyfarwyddiadau (y ddogfen hon)

4. Canllaw Gosod

Pwysig: Installation should only be performed by a competent person or qualified electrician. Ensure the mains power supply is switched off at the consumer unit before commencing installation.

4.1. Camau Cyn Gosod:

  1. Dewis Lleoliad: Choose a suitable location on the ceiling, adhering to the placement guidelines (refer to Section 2).
  2. Pŵer Datgysylltu: Turn off the mains electricity supply to the circuit where the alarm will be installed.
  3. Install Backup Battery: Open the battery compartment on the alarm unit and insert the supplied 9V battery, observing polarity. Close the compartment securely.

4.2. Mounting the Alarm:

  1. Marciwch Bwyntiau Drilio: Hold the base plate against the ceiling at your chosen location and mark the two drilling points.
  2. Tyllau Dril: Drill holes at the marked points and insert the rawl plugs.
  3. Plât Sylfaen Mowntio: Secure the base plate to the ceiling using the provided screws.
  4. Cysylltu Wiring: Connect the mains wiring (Live, Neutral, Earth, and Interlink if applicable) to the terminal block provided. Ensure connections are secure and correct. The alarm unit connects to this terminal block.
  5. Attach Alarm Unit: Align the smoke alarm unit with the base plate and twist clockwise until it clicks securely into place.
FireAngel SW1-R Smoke Alarm easy installation steps

Figure 4: Visual guide for easy installation, showing steps like installing the backup battery, mounting the bracket, attaching the alarm, and connecting to mains power.

4.3. Interlinking Multiple Alarms:

The SW1-R can be hardwired and interconnected with up to 12 compatible FireAngel mains-powered smoke (SW1), heat (HW1), or carbon monoxide (CW1) alarms. To interlink, connect the interlink wire between the designated terminals on each alarm's base plate. When one interlinked alarm detects a hazard, all connected alarms will sound simultaneously.

4.4. Post-Installation Check:

  1. Adfer Pwer: Turn the mains electricity supply back on.
  2. Larwm Prawf: Press and hold the Test/Silence button for 5 seconds to confirm the alarm is functioning correctly. A loud, high-pitched sound indicates proper operation.

5. Cyfarwyddiadau Gweithredu

5.1. Gweithrediad arferol:

Under normal conditions, the alarm will periodically flash its LED indicator to show it is powered and monitoring for smoke. If smoke is detected, the alarm will sound a loud siren and the LED will flash rapidly.

5.2. Test/Silence Button:

  • Profi: Press and hold the large central Test/Silence button for approximately 5 seconds. The alarm will sound a loud siren, confirming its functionality. Release the button to stop the test. Perform this test monthly.
  • Silencing False Alarms: In the event of a nuisance alarm (e.g., from cooking fumes), press and hold the Test/Silence button. This will temporarily silence the alarm for approximately 8 minutes. The alarm will automatically reset after this period. If the smoke source persists, the alarm will reactivate.

5.3. Sleep Easy Function:

If the 9V backup battery is low, the alarm will emit a regular "chirp" sound. To temporarily silence these low battery chirps for up to 8 hours, press the Test/Silence button. This allows for an uninterrupted night's sleep while still maintaining protection. Replace the battery as soon as possible after using this function.

6. cynnal

Regular maintenance ensures the continued reliability and effectiveness of your smoke alarm.

  • Prawf Misol: Press the Test/Silence button monthly to ensure the alarm is functioning correctly.
  • Quarterly Cleaning: Vacuum the alarm gently every 3 months using a soft brush attachment to remove dust and debris from the sensing chamber. This helps prevent false alarms and maintains sensor sensitivity.
  • Amnewid Batri: Replace the 9V backup battery immediately when the alarm emits low battery chirps that cannot be silenced or if the Sleep Easy function is used.
  • Osgoi Cemegau: PEIDIWCH use cleaners, solvents, or paint on the alarm.
  • Cover During DIY: Cover the alarm when performing dusty DIY tasks nearby to prevent dust ingress, then uncover and vacuum thoroughly afterwards.
FireAngel SW1-R Smoke Alarm maintenance tips

Figure 5: Visual summary of key maintenance recommendations for the smoke alarm, including monthly testing and quarterly vacuuming.

7. Datrys Problemau

If your smoke alarm is not operating as expected, refer to the following table for common issues and solutions:

ProblemAchos PosiblAteb
Alarm chirps intermittentlyLow 9V backup battery.Replace the 9V battery immediately. Use the Sleep Easy function if needed for temporary silence.
Alarm sounds without visible smoke (false alarm)Dust or debris in the sensing chamber; high humidity; cooking fumes; steam.Press the Test/Silence button to temporarily silence. Vacuum the alarm thoroughly. Relocate the alarm if it's consistently affected by cooking fumes or steam.
Nid yw'r larwm yn canu yn ystod y prawfNo mains power; flat 9V backup battery; faulty unit.Check mains power supply. Replace 9V battery. If problem persists, contact customer support.
Interlinked alarms do not all soundFaulty interlink wiring; incompatible alarms; too many alarms interlinked.Check interlink wiring connections. Ensure all interlinked alarms are compatible FireAngel models. Do not exceed 12 interlinked alarms.

8. Manylebau Technegol

Rhif ModelSW1-R
Math SynhwyryddOptical (Photoelectric)
Ffynhonnell PwerMains Powered (230V AC) with 9V DC Battery Backup
Cyfrol Larwm85dB ar 3 metr
Interlink CapabilityUp to 12 compatible FireAngel mains-powered alarms
Dimensiynau Cynnyrch (D x W x H)4.2D x 12.6W x 12.6H Centimetrau
Pwysau Eitem220 gram
Tymheredd GweithreduRefer to product packaging for specific range
Ystod LleithderRefer to product packaging for specific range
SafonauBS EN 14604:2005
UPC816317004422
FireAngel SW1-R Smoke Alarm with UKCA and CE marks

Figure 6: The FireAngel SW1-R Smoke Alarm displaying its UKCA and CE certifications, indicating compliance with safety standards.

9. Gwarant a Chymorth i Gwsmeriaid

9.1. Gwybodaeth Gwarant:

The FireAngel SW1-R Mains Smoke Alarm comes with a Gwarant 5 mlynedd o ddyddiad y pryniant. Mae'r warant hon yn cwmpasu diffygion mewn deunyddiau a chrefftwaith o dan ddefnydd arferol. Cadwch eich prawf prynu ar gyfer hawliadau gwarant.

The warranty does not cover damage caused by misuse, accidental damage, unauthorized modifications, or failure to follow the instructions in this manual.

9.2. Cefnogaeth i Gwsmeriaid:

For technical assistance, warranty claims, or further information regarding your FireAngel SW1-R smoke alarm, please contact FireAngel customer support. Refer to the FireAngel official website or product packaging for the most up-to-date contact details.

Websafle: www.fireangel.co.uk (exampy ddolen, gall y ddolen wirioneddol amrywio yn ôl rhanbarth)

© 2023 FireAngel Safety Technology Ltd. All rights reserved.

Gall y llawlyfr hwn newid heb rybudd.

Dogfennau Cysylltiedig - SW1-R

Cynview Llawlyfr Defnyddiwr Larwm Mwg Optegol FireAngel SW1
User manual for the FireAngel SW1 Optical Smoke Alarm, providing installation, operation, maintenance, troubleshooting, warranty, and disposal information.
Cynview FireAngel HW1 Mains Powered Heat Alarm User Manual
Comprehensive user manual for the FireAngel HW1 Mains Powered Heat Alarm with 9V battery backup. Includes installation, positioning, silencing features, interconnecting options, maintenance, troubleshooting, and warranty information.
Cynview FireAngel Smoke & Heat Alarm User Manual: FA6611, FA6615, FA6620, FA6720
Comprehensive user manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Covers installation, maintenance, troubleshooting, warranty, and disposal.
Cynview FireAngel ST-625-INT Smoke Alarm User Manual
Comprehensive user manual for the FireAngel ST-625-INT smoke alarm, covering installation, features, maintenance, and warranty. This guide provides essential safety information and operational instructions.
Cynview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Cynview Llawlyfr Defnyddiwr Larwm Mwg a Charbon Monocsid Cyfuniad FireAngel SCB10
User manual for the FireAngel SCB10, a combination smoke and carbon monoxide alarm, providing comprehensive instructions on installation, operation, maintenance, and safety for residential use.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.