SEBSON IR_ES_EA

SEBSON Recessed Ceiling Motion Detector (IR_ES_EA) - Anthracite

Llawlyfr Cyfarwyddiadau

1. Rhagymadrodd

Thank you for choosing the SEBSON Recessed Ceiling Motion Detector. This device is designed for indoor use to automatically control lighting based on motion and ambient light levels. Please read this manual carefully before installation and operation to ensure proper function and safety.

Blaen view of the SEBSON recessed ceiling motion detector with key specifications overlaid: 8m/360° detection, up to 1000W LED, IP20, 10sec-30min timer, 3-2000 LUX, 230V.
Ffigur 1: Drosoddview of the motion detector and its main features.

2. Cyfarwyddiadau Diogelwch

  • Rhaid i drydanwr cymwys gyflawni'r gosodiad yn unol â rheoliadau gwifrau lleol.
  • Disconnect power at the main circuit breaker before installation or maintenance.
  • Do not exceed the maximum load capacity of the detector (2000W for incandescent, 1000W for LED).
  • Mae'r cynnyrch hwn wedi'i gynllunio ar gyfer defnydd dan do yn unig. Osgoi amlygiad i leithder neu dymheredd eithafol.
  • Sicrhewch awyru priodol o amgylch y ddyfais.

3. Nodweddion Cynnyrch

  • Indoor motion detector for recessed ceiling mounting.
  • Wide detection range of 8 meters and 360 degrees.
  • Adjustable operating duration from 10 seconds to 30 minutes.
  • Adjustable ambient light sensitivity from 3 to 2000 lux.
  • Compatible with LED lighting (max 1000W) and incandescent bulbs (max 2000W).
  • 3-wire connection for reliable operation.

4. Cynnwys Pecyn

  • 1x SEBSON Recessed Ceiling Motion Detector (Anthracite)
  • 1x Llawlyfr Cyfarwyddiadau

5. Gosod

Pwysig: Ensure power is disconnected at the main circuit breaker before starting installation.

  1. Prepare a mounting hole in the ceiling with a diameter of 63-66 mm. Ensure there is sufficient depth (minimum 45 mm) for the detector.
  2. Connect the wiring according to the diagram below. The detector requires a 3-wire connection (Live, Neutral, Switched Live).
  3. Insert the detector into the prepared hole. The spring clips will secure it in place.
  4. Restore power and test the functionality.

5.1. Cynnyrch Drosview a Dimensiynau

Blaen view of the SEBSON recessed ceiling motion detector in anthracite color.
Ffigur 2: Blaen view of the motion detector. This image shows the anthracite-colored circular housing with the central infrared sensor dome.
Technical drawing showing the dimensions of the motion detector: 75mm diameter, 42mm height, 60mm internal width, 34mm internal height, 31mm spring length, 3mm bezel thickness.
Figure 3: Detailed dimensions of the motion detector. The overall diameter is 75mm, and the height is 42mm. The mounting hole diameter should be between 63-66mm.
Ochr view diagram illustrating the recessed installation, showing a minimum installation depth of 45mm and a ceiling thickness of up to 20mm.
Figure 4: Installation depth requirement. A minimum depth of 45mm is needed for proper recessed mounting.
Cefn view of the motion detector showing the wiring terminal block and spring clips.
Ffigur 5: Cefn view showing the wiring terminal. This is where the Live, Neutral, and Switched Live wires are connected.

6. Gweithredu ac Addasiadau

The motion detector features two adjustable dials on the back for 'TIME' (duration) and 'LUX' (light sensitivity).

Cefn view of the motion detector showing the 'TIME' and 'LUX' adjustment dials. The TIME dial ranges from 10s to 30min, and the LUX dial from 3 to 2000 lux.
Figure 6: Adjustment dials for TIME and LUX settings.

6.1. TIME Adjustment

The 'TIME' dial controls how long the connected light remains on after motion is detected and no further motion is sensed. Rotate the dial to set the desired duration:

  • 10s: Minimum duration (10 seconds).
  • 30 munud: Maximum duration (30 minutes).

6.2. LUX Adjustment

The 'LUX' dial determines the ambient light level at which the detector will activate. This allows the light to only turn on when it's dark enough.

  • 3: Activates only in very dark conditions (e.g., night).
  • 2000: Activates in all light conditions (day and night).

To set the LUX level, turn the dial to the sun symbol (2000 lux) for testing during daylight. Once satisfied with the detection, adjust the dial towards the moon symbol (3 lux) to the desired ambient light level for automatic operation.

6.3. Amrediad Canfod

Diagram showing the 360-degree detection area of the motion detector, with a maximum range of 8 meters and an installation height between 1.8m and 4m.
Figure 7: Detection range and angle. The detector covers a 360-degree area with a maximum range of 8 meters when installed at a height between 1.8m and 4m.

The detector has a 360° detection angle and a maximum range of 8 meters. Optimal installation height is between 1.8m and 4m. Avoid installing near heat sources, direct sunlight, or areas with significant air movement (e.g., air conditioning vents) to prevent false triggers.

7. cynnal

The SEBSON motion detector requires minimal maintenance. Ensure the sensor lens is kept clean and free from dust or obstructions. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.

8. Datrys Problemau

Problem Achos Posibl Ateb
Nid yw golau yn troi ymlaen.
  • Dim cyflenwad pŵer.
  • LUX setting too low (too dark).
  • Dim symudiad wedi'i ganfod o fewn yr ystod.
  • Gwifrau diffygiol.
  • Check circuit breaker and connections.
  • Adjust LUX dial towards the sun symbol.
  • Ensure motion occurs within the detection zone.
  • Gwiriwch gysylltiadau gwifrau.
Mae'r golau ymlaen yn gyson.
  • Continuous motion in detection zone.
  • Mae'r gosodiad TIME yn rhy hir.
  • Wiring error (e.g., switched live permanently connected).
  • Clear detection zone of constant movement.
  • Adjust TIME dial to a shorter duration.
  • Check wiring for correct connections.
Mae golau'n troi ymlaen heb symudiad amlwg.
  • Heat sources (e.g., heater, direct sunlight).
  • Air currents (e.g., open window, AC vent).
  • Small animals.
  • Relocate detector or remove interfering objects.
  • Ensure stable environment.
  • Adjust sensitivity if possible (this model does not have explicit sensitivity adjustment, but careful placement can help).

9. manylebau

Brand SEBSON
Rhif Model IR_ES_EA
Lliw Anthracite
Dimensiynau (L x W x H) 7.5 x 7.5 x 7.5 cm
Pwysau 110 gram
Math Mowntio Cilannog (nenfwd)
Diamedr Mowntio Twll 63-66 mm
Ffynhonnell Pwer Pŵer AC
Llwyth Uchaf (Gwynias) 2000 Gw
Max Load (LED/Energy Saving) 1000 Gw
Amrediad Canfod 8 metr
Ongl Canfod 360°
Operating Duration (TIME) 10 eiliad - 30 munud
Ambient Light Sensitivity (LUX) 3 - 2000 lux
Dyfeisiau Cydnaws Basic lighting controls
Defnyddiau a Argymhellir Residential security, commercial security, automation, energy management
Gwlad Tarddiad Tsieina

10. Gwarant a Chefnogaeth

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official SEBSON websafle. Cadwch eich prawf prynu ar gyfer hawliadau gwarant.

© 2026 SEBSON. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.