This manual provides essential instructions for the safe and effective use of your VEVOR Premium 3 Function Full Electric Hospital Bed. This bed is designed to offer adjustable positioning for patient comfort and care in various settings, including home, rehabilitation centers, and medical facilities. Please read this manual thoroughly before assembly, operation, or maintenance to ensure proper usage and to prevent injury or damage.

Image: The VEVOR Premium 3 Function Full Electric Hospital Bed with mattress and IV pole, shown in a slightly elevated position.
Gwybodaeth Diogelwch
Adherence to the following safety guidelines is crucial for preventing accidents and ensuring the longevity of your hospital bed:
- Dilynwch y cyfarwyddiadau cydosod yn ofalus bob amser.
- Keep the bed area clear of children and pets when the bed is in use or being adjusted.
- Peidiwch â bod yn fwy na'r capasiti pwysau uchaf o 440 pwys (200 kg).
- Ensure the control panel and all electrical components remain dry. Avoid contact with liquids.
- Regularly inspect the bed for any signs of damage, wear, or loose components. Address any issues immediately.
- Always turn off the bed and unplug the power cord when not in use, during cleaning, or when leaving the room for extended periods.
- Ensure all casters are locked when the bed is stationary to prevent unintended movement.
- Use side rails appropriately to prevent falls, but be aware that side rails are not a substitute for supervision.
Cynnyrch Drosview a Nodweddion
The VEVOR Premium 3 Function Full Electric Hospital Bed offers advanced features for patient comfort and caregiver convenience:
- 3 Adjustable Functions:
- Full bed elevation: 15.7 - 28.0 inches (400 - 710 mm)
- Backrest angle adjustment: 0-84°
- Leg position adjustment: 0-47°
- User-Friendly Handheld Controller: Intuitive controls for easy adjustment of bed positions.
- High-Quality Mattress: 15cm (approximately 5.9 inches) memory foam mattress designed for comfort, support, and liquid penetration prevention.
- Integrated IV Pole: Convenient for medical and home care needs.
- 5-Inch Locking Casters: Provides smooth mobility and secure locking for stability.
- Adeiladu Cadarn: Supports a strong load-bearing capacity of 440 lbs (200 kg).

Image: A patient comfortably seated in the VEVOR hospital bed, demonstrating the adjustable backrest and legrest angles, along with the overall bed elevation range.

Delwedd: Ffrwydrad view diagram highlighting key components of the VEVOR hospital bed, including footboard, casters, guardrails, bed surface board, bed frame, mattress holder, and headboard.
Cyfarwyddiadau Gosod
Assembly of the VEVOR hospital bed requires careful attention. It is recommended that dau berson perform the assembly due to the bed's weight and size. Ensure you have adequate space and the necessary tools (e.g., two wrenches) before beginning.
- Dadbacio: Carefully unpack all components from the packaging. Retain packaging materials until assembly is complete, as they can protect flooring during the process.
- Initial Positioning: Place the main bed frame upside down in the desired assembly area.
- Atodwch olwynion: Securely attach the 5-inch locking casters to the designated points on the underside of the bed frame. Ensure they are firmly tightened.
- Flip the Bed: With the assistance of another person, carefully flip the bed frame right-side up, resting it on its newly installed casters.
- Gosod Rheiliau Ochr: Attach the safety guardrails to both sides of the bed frame. Ensure they are properly aligned and secured according to the specific hardware provided.
- Attach Head and Foot Boards: Slide or attach the headboard and footboard into their respective slots or mounting points.
- Matres Lle: Position the 15cm memory foam mattress onto the bed surface.
- Install IV Pole: Insert the IV pole into its designated receptacle on the bed frame.
- Pwer Cysylltu: Plug the bed's power cord into a grounded electrical outlet.
- Swyddogaethau Prawf: Before use, test all adjustable functions using the handheld controller to ensure proper operation.

Delwedd: Manwl view of the 5-inch aluminum locking casters, illustrating their robust design and locking mechanism for secure positioning.
Cyfarwyddiadau Gweithredu
The VEVOR hospital bed is operated using a handheld controller. Familiarize yourself with the buttons before adjusting the bed with a patient on it.

Image: The handheld controller for the VEVOR hospital bed, showing eight distinct buttons for various adjustments. Each button is labeled with its function, such as "Back up," "Back down," "Leg up," "Leg down," "Back and leg linkage up (auto-contour)," "Back and leg linkage down (auto-contour)," "Whole bed up," and "Whole bed down."
- Addasiad cynhalydd cefn: Use the "Back up button" to raise the backrest and the "Back down button" to lower it.
- Leg Position Adjustment: Use the "Leg up button" to raise the leg section and the "Leg down button" to lower it.
- Auto-Contour Function: The "Back and leg linkage up (auto-contour) button" simultaneously raises both the backrest and leg section for a comfortable seated position. The "Back and leg linkage down (auto-contour) button" lowers both sections.
- Whole Bed Elevation: Use the "Whole bed up button" to raise the entire bed frame and the "Whole bed down button" to lower it.
- Castrau Cloi: To prevent accidental movement, always engage the locks on all four casters when the bed is in a stationary position.
- Rheiliau Ochr: Raise the side rails when the patient is unattended or requires fall prevention. Ensure they are securely locked in the upright position. Lower them for patient entry/exit or caregiver access.
Cynnal a chadw
Regular maintenance ensures the safe and efficient operation of your VEVOR hospital bed.
- Glanhau:
- Datgysylltu pŵer cyn glanhau.
- Wipe down all surfaces of the bed frame, headboard, footboard, and side rails with a mild, non-abrasive cleaner and a damp brethyn.
- The mattress cover is designed to prevent liquid penetration and can be wiped clean with a damp cloth and mild disinfectant. Do not immerse the mattress in water.
- Ensure all components are dry before reconnecting power.
- Arolygiad:
- Periodically check all bolts, screws, and fasteners to ensure they are tight.
- Inspect the power cord for any cuts, fraying, or damage. Replace immediately if damaged.
- Verify that all casters roll freely and that their locking mechanisms function correctly.
- Check the functionality of the handheld controller and all bed adjustments.
- Ensure side rails move smoothly and lock securely in both raised and lowered positions.
- Iro: Moving parts may occasionally benefit from light lubrication with a silicone-based spray, as recommended by the manufacturer. Avoid over-lubrication.
Datrys problemau
If you encounter issues with your VEVOR hospital bed, refer to the following common troubleshooting steps:
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Bed does not respond to controller. |
|
|
| Bed makes unusual noises during adjustment. |
|
|
| Bed functions are sluggish or inconsistent. |
|
|
| Casters do not lock or roll smoothly. |
|
|
Os yw'r broblem yn parhau ar ôl rhoi cynnig ar yr atebion hyn, cysylltwch â chymorth cwsmeriaid VEVOR.
Manylebau
| Nodwedd | Manylyn |
|---|---|
| Rhif Model | 3 Swyddogaethau |
| Dimensiynau Eitem (L x W x H) | 83.1 x 38.6 x 15.7-28.0 inches (2110 x 980 x 400-710 mm) |
| Dimensiynau Matres | 75.6 x 32.3 modfedd (1920 x 820 mm) |
| Deunydd | Dur Plastig |
| Gallu Pwysau | 440 pwys (200 kg) |
| Pwysau Net | 217.2 pwys (98.5 kg) |
| Whole Bed Elevation | 15.7 - 28.0 modfedd (400 - 710 mm) |
| Backrest Elevation Angle | 0 - 84° |
| Legrest Elevation Angle | 0 - 47° |
| Maint Caster | 5 modfedd |
| Lliw | Multi-color (White and Blue accents) |
| UPC | 197988846697 |

Image: A diagram illustrating the key dimensions of the VEVOR hospital bed, including length, width, and height ranges, along with backrest and legrest elevation angles.
Gwarant a Chefnogaeth
VEVOR is committed to providing quality products. For information regarding product warranty, please refer to the documentation included with your purchase or visit the official VEVOR websafle.
- Yn dychwelyd: Mae'r cynnyrch hwn fel arfer yn cynnwys polisi dychwelyd hawdd 30 diwrnod. Gwiriwch fanylion eich pryniant am delerau penodol.
- Cynlluniau Diogelu: Extended protection plans may be available for purchase separately to cover potential issues beyond the standard warranty period.
- Cefnogaeth i Gwsmeriaid: For technical assistance, troubleshooting not covered in this manual, or warranty claims, please contact VEVOR customer support. Refer to your purchase documentation or the VEVOR websafle ar gyfer gwybodaeth cyswllt.