This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Metabo TBP 6200/8 INOX submersible borehole pump. Please read these instructions carefully before using the pump for the first time. Keep this manual in a safe place for future reference.
Cyfarwyddiadau Diogelwch
Dilynwch y rhagofalon diogelwch canlynol bob amser i atal anaf personol a difrod i'r offer:
- Ensure the power supply matches the specifications on the pump's rating plate.
- Never operate the pump without water. Dry running can cause severe damage.
- Do not use the power cable to lift or lower the pump. Always use a suitable rope or chain.
- Disconnect the pump from the power supply before performing any maintenance or cleaning.
- Cadwch blant a phobl heb awdurdod i ffwrdd o'r pwmp sy'n gweithredu.
- Ensure proper grounding of the electrical connection.
- Do not pump flammable, explosive, or corrosive liquids.
Gosod
1. Dadbacio ac Arolygu
Carefully remove the pump from its packaging. Inspect the pump for any signs of damage that may have occurred during transit. If any damage is found, do not use the pump and contact your supplier.
2. Attaching the Suspension Rope
Attach a strong, non-stretchable rope or chain to the designated eyelets on the pump. This rope will be used to lower and retrieve the pump from the borehole. Ensure the knot is secure.

Image: Securely tying a suspension rope to the pump's attachment point. This rope is crucial for safe installation and retrieval of the pump from the borehole.
3. Connecting the Discharge Hose/Pipe
Connect a suitable discharge hose or pipe to the pump's outlet. Ensure all connections are tight and leak-free. Use appropriate sealing materials if necessary.

Image: Connecting the discharge hose to the pump. Proper sealing ensures efficient water transfer and prevents leaks.
4. Lowering the Pump into the Borehole
Carefully lower the pump into the borehole using the attached suspension rope. Ensure the pump is fully submerged and positioned correctly, avoiding contact with the bottom or sides of the well to prevent sediment intake or damage.

Image: Lowering the submersible pump into a borehole. The pump must be fully submerged for proper operation.
5. Cysylltiad Trydanol
Connect the pump's power cable to a suitable, grounded electrical outlet. Ensure the circuit is protected by a residual current device (RCD) for safety.
Cyfarwyddiadau Gweithredu
1. Cychwyn y Pwmp
Once the pump is fully submerged and all connections are secure, switch on the power supply. The pump will begin to draw water. Monitor the initial operation for any unusual noises or vibrations.
2. Monitoring Operation
Regularly check the water flow and pressure. If the flow decreases significantly or the pump makes unusual noises, switch it off immediately and investigate the cause.

Image: The pump in operation, supplying water for garden irrigation. Ensure consistent water flow during use.

Image: The pump effectively powering a sprinkler system for garden watering, demonstrating its application.
3. Cau i Lawr
To stop the pump, simply switch off the power supply. If the pump will not be used for an extended period, disconnect it from the power source and follow the maintenance and storage guidelines.
Cynnal a chadw
1. Glanhau Rheolaidd
Periodically remove the pump from the borehole and clean its exterior, especially the intake screen, to prevent blockages. Use clean water and a soft brush. Do not use harsh chemicals.
2. Paratoi ar gyfer y gaeaf
In regions with freezing temperatures, remove the pump from the borehole before winter. Drain all water from the pump and hoses to prevent damage from freezing. Store the pump in a dry, frost-free location.
3. Storio
When not in use, store the pump in a clean, dry, and well-ventilated area, protected from direct sunlight and extreme temperatures.
Datrys problemau
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw pwmp yn dechrau | Dim cyflenwad pŵer Gorlwytho thermol wedi'i actifadu Impeller rhwystro | Gwiriwch y cysylltiad pŵer a'r torrwr cylched Allow pump to cool down Datgysylltwch y pŵer a chliriwch y rhwystr |
| Llif dŵr llai | Sgrin cymeriant rhwystredig Pibell wedi'i chicio neu wedi'i rhwystro Lefel dŵr isel yn y ffynnon | Clean intake screen Check and clear hose Wait for water level to rise or reposition pump |
| Pump runs but no water | Nid yw'r pwmp wedi'i foddi'n llawn System aer i mewn Check valve faulty | Ensure pump is submerged Gwaedu aer o'r system Inspect or replace check valve |
| Gormod o sŵn/dirgryniad | Gwrthrych tramor yn y pwmp Bearings gwisgo Pump touching well walls | Disconnect power and inspect impeller Cysylltwch â phersonél gwasanaeth cymwys Adjust pump position |
Manylebau

Image: The Metabo TBP 6200/8 INOX submersible pump. Its robust stainless steel construction is designed for durability.
- Rhif Model: 610217000
- Dimensiynau (L x W x H): 45 x 24 x 24 cm
- Pwysau: 9.3 Cilogram
- Deunydd: Dur Di-staen
- Power (Motor): 1100 Wat
- Ffynhonnell Pwer: Cebl Trydan
- Gwneuthurwr: Metabo
- Gwlad Tarddiad: Almaen
Cromlin Perfformiad

Image: Performance curve for the TBP 6200/8 INOX pump. This graph illustrates the relationship between flow rate, head, and pressure, indicating the pump's operational capabilities under various conditions.
Gwarant a Chefnogaeth
For warranty information, technical support, or spare parts, please contact your authorized Metabo dealer or visit the official Metabo websafle. Cadwch eich derbynneb prynu fel prawf o brynu.