Skyking IR-950

Skyking WORK-ZONE IR-950 Industrial Infrared Thermometer User Manual

Model: IR-950

1. Rhagymadrodd

The Skyking WORK-ZONE IR-950 is a high-performance industrial infrared thermometer designed for non-contact temperature measurement. It is ideal for use in various industrial applications such as furnaces, kilns, forging, casting, and HVAC systems, where high temperatures need to be measured safely and accurately. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device.

WORK-ZONE IR-950 Industrial Infrared Thermometer front view

Ffigur 1.1: Blaen view of the WORK-ZONE IR-950 Industrial Infrared Thermometer, showing the display and trigger.

2. Gwybodaeth Diogelwch

Please read and understand all safety warnings and operating instructions before using this instrument. Failure to do so may result in injury or damage to the device.

  • RHYBUDD: Mae'r ddyfais hon yn NOT FOR HUMAN temperature measurement. It is designed for industrial applications only.
  • Do not point the laser directly at eyes or indirectly off reflective surfaces. Laser radiation can cause eye damage.
  • Do not use the thermometer near explosive gas, steam, or dust.
  • Avoid exposing the device to extreme temperatures, humidity, or direct sunlight for prolonged periods.
  • Do not attempt to disassemble or modify the instrument. Refer all servicing to qualified personnel.
  • Cadwch y ddyfais allan o gyrraedd plant.

3. Cydrannau Cynnyrch

The WORK-ZONE IR-950 package typically includes the following items:

  • WORK-ZONE IR-950 Industrial Infrared Thermometer
  • Llawlyfr Defnyddiwr (y ddogfen hon)
  • Batteries (may be included or sold separately, refer to packaging)

4. Gosod

4.1 Gosod Batri

  1. Lleolwch glawr adran y batri ar ddolen y thermomedr.
  2. Agorwch y clawr adran batri.
  3. Insert two 1.5V AA batteries (or No.7 batteries) according to the polarity indicators (+ and -) inside the compartment.
  4. Caewch y clawr adran batri yn ddiogel.

4.2 Pŵer Cychwynnol Ymlaen

After installing the batteries, press the trigger to power on the device. The LCD display will illuminate, showing the current temperature and other indicators.

WORK-ZONE IR-950 Industrial Infrared Thermometer display

Ffigur 4.1: Brig view of the IR-950, highlighting the digital display.

5. Cyfarwyddiadau Gweithredu

5.1 Cymryd Mesur

  1. Point the thermometer at the target surface. Ensure the target is larger than the spot size indicated by the D:S ratio (see Section 5.2).
  2. Press and hold the trigger. The laser pointer(s) will activate, indicating the measurement area.
  3. The measured temperature will be displayed on the LCD screen within 0.25 seconds.
  4. Release the trigger to hold the reading on the display. The device will automatically shut down after approximately 7 seconds of inactivity to conserve battery.

5.2 Cymhareb Pellter i Fan (D:S)

The IR-950 has a Distance to Spot Ratio (D:S) of 12:1. This means that at a distance of 12 units from the target, the measurement spot diameter will be 1 unit. For accurate readings, ensure the target area is completely within the measurement spot. Measuring closer to the target will result in a smaller spot size and more precise measurement of a specific area.

WORK-ZONE IR-950 Distance to Spot Ratio diagram

Ffigur 5.1: Diagram illustrating the 12:1 Distance to Spot Ratio.

5.3 Adjustable Emissivity

Emissivity (ε) is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. The IR-950 allows you to adjust the emissivity from 0.10 to 1.00 (preset to 0.95) to ensure accurate readings for various surfaces. Consult an emissivity table for common materials or adjust empirically for best results.

  • Gwasgwch y MODD button to cycle through settings until 'Emissivity' is displayed.
  • Defnyddiwch y I FYNY/I LAWR buttons (often combined with laser/backlight buttons) to adjust the value.
  • Gwasgwch MODD eto i gadarnhau ac ymadael.

5.4 MAX/MIN Display

The thermometer can display the maximum (MAX) or minimum (MIN) temperature recorded during a continuous measurement session. This feature is useful for monitoring temperature fluctuations.

  • While holding the trigger, press the MODD button to cycle through display modes (e.g., current, MAX, MIN).
  • The corresponding value will be shown on the display.

5.5 Unit Conversion (°C/°F)

To switch between Celsius (°C) and Fahrenheit (°F) temperature units:

  • With the device powered on, press the dedicated °C/°F button, or cycle through the MODD button until the unit option appears, then use the I FYNY/I LAWR botymau i ddewis.

6. cynnal

6.1 Glanhau

  • The lens is the most delicate part of the thermometer. Clean it with a soft, damp cloth or cotton swab. Do not use abrasive cleaners or solvents.
  • Glanhewch yr offeryn casing gyda hysbysebamp cloth and mild soap. Do not immerse the device in water.

6.2 Storio

  • Storiwch y thermomedr mewn lle oer, sych, i ffwrdd o olau haul uniongyrchol a thymheredd eithafol.
  • Tynnwch y batris os na fydd y ddyfais yn cael ei defnyddio am gyfnod hir er mwyn atal gollyngiadau.

7. Datrys Problemau

Problem Achos Posibl Ateb
Nid yw'r ddyfais yn pweru ymlaen. Batris marw neu wedi'u gosod yn anghywir. Amnewidiwch y batris neu gwnewch yn siŵr bod y polaredd yn gywir.
Darlleniadau anghywir. Incorrect emissivity setting, target too small, or lens dirty. Adjust emissivity, ensure target is within spot size, clean the lens.
"Hi" or "Lo" displayed. Temperature exceeds measurement range. Ensure the measured temperature is within the device's specified range (-50 to 950°C).
"AH" or "AL" displayed. Ambient temperature exceeds working environment limits. Operate the device within the specified working environment temperature (0°C~40°C).
Low power indicator (blank display). Batri cyftage yn is na 2.5V. Amnewid batris.

8. manylebau

Nodwedd Manylyn
Arddangos LCD lliwgar
Amrediad Tymheredd -50°C i 950°C (-58°F i 1742°F)
Gwall Mesur Tymheredd
  • <0°C (32°F): ±3°C (±5°F)
  • >0°C (32°F): ±1.5°C (±2.7°F) or ±1.5% (whichever is greater)
Ailadroddadwyedd 1% reading or 1°C (whichever is greater)
Amser Ymateb 0.5 seconds (95% response)
Allyredd 0.10 - 1.00 (Adjustable, preset to 0.95)
Cymhareb Pellter i Fan (D:S) 12:1
Tonfedd Ymateb 5µm ~ 14µm
Auto Shutdown Approximately 7 seconds of no operation
Batris 2 x 1.5V AA batteries (No.7 battery)
Dangosydd Pwer Isel Display shows blank when battery level is below 2.5V
Dangosydd Gorlwytho "Hi" / "Lo" displayed on LCD
Work Environment Limits Exceeded "AH" / "AL" displayed on LCD
Tymheredd Amgylchedd Gwaith 0°C ~ 40°C (32°F ~ 104°F)
Tymheredd Storio -10 ° C ~ 60 ° C (14 ° F ~ 140 ° F)
Deunydd Clorid Polyvinyl
Lliw Coch
Cydymffurfiad ISO 9001
Gwlad Tarddiad Tsieina

9. Gwarant a Chefnogaeth

9.1 Gwybodaeth Gwarant

This product may be eligible for an extended warranty. Please refer to your purchase documentation or contact your retailer for details regarding warranty coverage. A 1-year extended warranty by Onsitego may be available for purchase.

9.2 Cefnogaeth i Gwsmeriaid

For technical assistance, troubleshooting, or service inquiries, please contact Skyking Instruments customer support. You may find contact information on your product packaging or purchase invoice.

  • Cyswllt Gwneuthurwr: 9820050056 (WORK-ZONE)
  • Cyswllt y Pecynwr: Skyking Instruments

© 2024 Skyking Instruments. All rights reserved.

Gall y wybodaeth yn y llawlyfr hwn newid heb rybudd.

Ask a question about this manual