1. Rhagymadrodd
The Skyking WORK-ZONE IR-950 is a high-performance industrial infrared thermometer designed for non-contact temperature measurement. It is ideal for use in various industrial applications such as furnaces, kilns, forging, casting, and HVAC systems, where high temperatures need to be measured safely and accurately. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device.
Ffigur 1.1: Blaen view of the WORK-ZONE IR-950 Industrial Infrared Thermometer, showing the display and trigger.
2. Gwybodaeth Diogelwch
Please read and understand all safety warnings and operating instructions before using this instrument. Failure to do so may result in injury or damage to the device.
- RHYBUDD: Mae'r ddyfais hon yn NOT FOR HUMAN temperature measurement. It is designed for industrial applications only.
- Do not point the laser directly at eyes or indirectly off reflective surfaces. Laser radiation can cause eye damage.
- Do not use the thermometer near explosive gas, steam, or dust.
- Avoid exposing the device to extreme temperatures, humidity, or direct sunlight for prolonged periods.
- Do not attempt to disassemble or modify the instrument. Refer all servicing to qualified personnel.
- Cadwch y ddyfais allan o gyrraedd plant.
3. Cydrannau Cynnyrch
The WORK-ZONE IR-950 package typically includes the following items:
- WORK-ZONE IR-950 Industrial Infrared Thermometer
- Llawlyfr Defnyddiwr (y ddogfen hon)
- Batteries (may be included or sold separately, refer to packaging)
4. Gosod
4.1 Gosod Batri
- Lleolwch glawr adran y batri ar ddolen y thermomedr.
- Agorwch y clawr adran batri.
- Insert two 1.5V AA batteries (or No.7 batteries) according to the polarity indicators (+ and -) inside the compartment.
- Caewch y clawr adran batri yn ddiogel.
4.2 Pŵer Cychwynnol Ymlaen
After installing the batteries, press the trigger to power on the device. The LCD display will illuminate, showing the current temperature and other indicators.
Ffigur 4.1: Brig view of the IR-950, highlighting the digital display.
5. Cyfarwyddiadau Gweithredu
5.1 Cymryd Mesur
- Point the thermometer at the target surface. Ensure the target is larger than the spot size indicated by the D:S ratio (see Section 5.2).
- Press and hold the trigger. The laser pointer(s) will activate, indicating the measurement area.
- The measured temperature will be displayed on the LCD screen within 0.25 seconds.
- Release the trigger to hold the reading on the display. The device will automatically shut down after approximately 7 seconds of inactivity to conserve battery.
5.2 Cymhareb Pellter i Fan (D:S)
The IR-950 has a Distance to Spot Ratio (D:S) of 12:1. This means that at a distance of 12 units from the target, the measurement spot diameter will be 1 unit. For accurate readings, ensure the target area is completely within the measurement spot. Measuring closer to the target will result in a smaller spot size and more precise measurement of a specific area.
Ffigur 5.1: Diagram illustrating the 12:1 Distance to Spot Ratio.
5.3 Adjustable Emissivity
Emissivity (ε) is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. The IR-950 allows you to adjust the emissivity from 0.10 to 1.00 (preset to 0.95) to ensure accurate readings for various surfaces. Consult an emissivity table for common materials or adjust empirically for best results.
- Gwasgwch y MODD button to cycle through settings until 'Emissivity' is displayed.
- Defnyddiwch y I FYNY/I LAWR buttons (often combined with laser/backlight buttons) to adjust the value.
- Gwasgwch MODD eto i gadarnhau ac ymadael.
5.4 MAX/MIN Display
The thermometer can display the maximum (MAX) or minimum (MIN) temperature recorded during a continuous measurement session. This feature is useful for monitoring temperature fluctuations.
- While holding the trigger, press the MODD button to cycle through display modes (e.g., current, MAX, MIN).
- The corresponding value will be shown on the display.
5.5 Unit Conversion (°C/°F)
To switch between Celsius (°C) and Fahrenheit (°F) temperature units:
- With the device powered on, press the dedicated °C/°F button, or cycle through the MODD button until the unit option appears, then use the I FYNY/I LAWR botymau i ddewis.
6. cynnal
6.1 Glanhau
- The lens is the most delicate part of the thermometer. Clean it with a soft, damp cloth or cotton swab. Do not use abrasive cleaners or solvents.
- Glanhewch yr offeryn casing gyda hysbysebamp cloth and mild soap. Do not immerse the device in water.
6.2 Storio
- Storiwch y thermomedr mewn lle oer, sych, i ffwrdd o olau haul uniongyrchol a thymheredd eithafol.
- Tynnwch y batris os na fydd y ddyfais yn cael ei defnyddio am gyfnod hir er mwyn atal gollyngiadau.
7. Datrys Problemau
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw'r ddyfais yn pweru ymlaen. | Batris marw neu wedi'u gosod yn anghywir. | Amnewidiwch y batris neu gwnewch yn siŵr bod y polaredd yn gywir. |
| Darlleniadau anghywir. | Incorrect emissivity setting, target too small, or lens dirty. | Adjust emissivity, ensure target is within spot size, clean the lens. |
| "Hi" or "Lo" displayed. | Temperature exceeds measurement range. | Ensure the measured temperature is within the device's specified range (-50 to 950°C). |
| "AH" or "AL" displayed. | Ambient temperature exceeds working environment limits. | Operate the device within the specified working environment temperature (0°C~40°C). |
| Low power indicator (blank display). | Batri cyftage yn is na 2.5V. | Amnewid batris. |
8. manylebau
| Nodwedd | Manylyn |
|---|---|
| Arddangos | LCD lliwgar |
| Amrediad Tymheredd | -50°C i 950°C (-58°F i 1742°F) |
| Gwall Mesur Tymheredd |
|
| Ailadroddadwyedd | 1% reading or 1°C (whichever is greater) |
| Amser Ymateb | 0.5 seconds (95% response) |
| Allyredd | 0.10 - 1.00 (Adjustable, preset to 0.95) |
| Cymhareb Pellter i Fan (D:S) | 12:1 |
| Tonfedd Ymateb | 5µm ~ 14µm |
| Auto Shutdown | Approximately 7 seconds of no operation |
| Batris | 2 x 1.5V AA batteries (No.7 battery) |
| Dangosydd Pwer Isel | Display shows blank when battery level is below 2.5V |
| Dangosydd Gorlwytho | "Hi" / "Lo" displayed on LCD |
| Work Environment Limits Exceeded | "AH" / "AL" displayed on LCD |
| Tymheredd Amgylchedd Gwaith | 0°C ~ 40°C (32°F ~ 104°F) |
| Tymheredd Storio | -10 ° C ~ 60 ° C (14 ° F ~ 140 ° F) |
| Deunydd | Clorid Polyvinyl |
| Lliw | Coch |
| Cydymffurfiad | ISO 9001 |
| Gwlad Tarddiad | Tsieina |
9. Gwarant a Chefnogaeth
9.1 Gwybodaeth Gwarant
This product may be eligible for an extended warranty. Please refer to your purchase documentation or contact your retailer for details regarding warranty coverage. A 1-year extended warranty by Onsitego may be available for purchase.
9.2 Cefnogaeth i Gwsmeriaid
For technical assistance, troubleshooting, or service inquiries, please contact Skyking Instruments customer support. You may find contact information on your product packaging or purchase invoice.
- Cyswllt Gwneuthurwr: 9820050056 (WORK-ZONE)
- Cyswllt y Pecynwr: Skyking Instruments