UNI-T UT665

UNI-T UT665 Industrial Endoscope Instruction Manual

Model: UT665

1. Cynnyrch Drosview

The UNI-T UT665 Industrial Endoscope is a non-destructive testing device designed for inspecting hard-to-reach areas. It features a high-definition probe, a 2.4-inch display, and IP67 waterproofing for reliable performance in various environments.

UNI-T UT665 Industrial Endoscope main unit with flexible probe

Image: The UNI-T UT665 Industrial Endoscope, showcasing its handheld unit and flexible camera probe.

2. Nodweddion Allweddol

  • Real-time Clear Display: Equipped with a 2.4-inch TFT screen (480x234 resolution) for immediate viewing.
  • Rotatable Images: Allows for image rotation to adjust viewcyfeiriadedd ing.
  • Flexible Camera Probe: Features a 1-meter coil length probe that can be bent and shaped for various inspection needs.
  • Adjustable Image Saturation: 6 levels of image saturation adjustment for optimal visual clarity.
  • Disgleirdeb LED Addasadwy: 4 levels of LED light intensity for illuminating dark inspection areas.
  • Probydd Gwrth-ddŵr IP67: The 9mm diameter probe is waterproof, suitable for wet environments.
  • Pellter Canolbwyntio: Optimal focus range of 20mm to 100mm.
  • Adeiladu Gwydn: Outer shell wrapped with soft rubber for shock-proof, waterproof, wear-resistant, and corrosion-resistant performance.
  • Dyluniad ergonomig: Handheld unit designed for comfortable and non-slip grip, lightweight and portable.
  • Bywyd batri hir: Provides 6-8 hours of operation on a single set of batteries.
UNI-T UT665 Endoscope held comfortably in hand

Image: The UT665 endoscope designed for portable and comfortable use, highlighting its ergonomic grip.

Close-up of the UT665 endoscope probe and main unit, emphasizing durability

Image: Detail of the UT665 endoscope, illustrating its robust and waterproof probe construction.

3. Cyfarwyddiadau Gosod

3.1 Cynnwys Pecyn

Mae'r pecyn yn cynnwys:

  • UT665 Main Unit
  • Flexible Camera Probe
  • Lithium Metal Batteries (4x 1.5V R6)
  • Llawlyfr Defnyddiwr

3.2 Gosod Batri

  1. Locate the battery compartment cover on the handle of the main unit.
  2. Open the cover and insert four 1.5V R6 (AA) batteries, ensuring correct polarity (+/-).
  3. Caewch y clawr adran batri yn ddiogel.

3.3 Cysylltiad Profi

  1. Align the connector of the flexible camera probe with the port on the top of the main unit.
  2. Gently push the probe connector into the port.
  3. Tighten the threaded collar on the probe connector to secure it to the main unit. Ensure it is firmly attached to prevent disconnection during use.
Diagram showing battery and probe installation steps for the UT665 endoscope

Image: Visual guide for installing batteries and connecting the probe to the UT665 main unit.

Video: A demonstration of the battery installation and probe connection process for the UNI-T UT665 Endoscope.

4. Cyfarwyddiadau Gweithredu

4.1 Pweru Ymlaen/Diffodd

  • I droi’r ddyfais ymlaen, pwyswch a daliwch y Grym botwm (Eicon botwm pŵer) until the screen illuminates.
  • I bweru i ffwrdd, pwyswch a dal y Grym botwm eto nes bod y sgrin yn diffodd.

4.2 Addasu Disgleirdeb LED

  • Gwasgwch y Ysgafn botwm (Eicon bylbiau golau) to cycle through the 4 levels of LED brightness.
  • Select the appropriate brightness for your inspection environment.

4.3 Adjusting Image Saturation

  • Gwasgwch y Dirlawnder botwm (Saturation icon) to adjust the image saturation through 6 available levels.
  • This helps optimize color representation for clearer viewing.

4.4 Cylchdro Delwedd

  • The device supports image rotation. Refer to the on-screen indicators or specific button functions for rotating the displayed image if needed.

4.5 Defnydd Cyffredinol

  • Once powered on and the probe is connected, carefully insert the flexible probe into the area you wish to inspect.
  • Observe the real-time image on the 2.4-inch display.
  • Maneuver the probe as needed to get the desired view.
Hands operating the UT665 endoscope, showing adjustments to LED brightness and image saturation

Image: The UT665 endoscope in use, demonstrating the clear imaging capabilities and adjustable settings.

5. cynnal

  • Glanhau: After each use, gently wipe the probe and main unit with a soft, dry cloth. For stubborn dirt on the probe, use a slightly damp cloth and ensure it is completely dry before storage. Do not use abrasive cleaners or solvents.
  • Storio: Store the endoscope in a cool, dry place away from direct sunlight and extreme temperatures. Disconnect the probe from the main unit and remove batteries if storing for extended periods.
  • Gofal Batri: Replace batteries when the low battery indicator appears. Always use fresh, high-quality batteries.
  • Trin y Chwiban: Avoid sharp bends or excessive force on the flexible probe to prevent internal damage.

6. Datrys Problemau

ProblemAchos PosiblAteb
Nid yw'r ddyfais yn pweru ymlaenLow or dead batteries; Incorrect battery installationReplace batteries with new ones; Check battery polarity.
Dim delwedd ar y sgrinProbe not connected securely; Damaged probe cableEnsure probe is firmly connected and collar is tightened; Contact support if probe is damaged.
Mae'r ddelwedd yn aneglur neu'n aneglurLens is dirty; Object is outside focusing distance; Insufficient lightingClean the probe lens; Adjust the distance to the object (20mm-100mm); Increase LED brightness.
Goleuadau LED ddim yn gweithioLED brightness set to minimum; Faulty LEDsPress the Light button to increase brightness; Contact support if LEDs remain non-functional.

7. manylebau

NodweddManylyn
Cydraniad Arddangos640x480 picsel
Diamedr Lens9mm (Max. 10mm)
Maint LCD2.4 modfedd
Hyd y Probe1m (3m opsiynol)
Math o SgrinTFT
Hyd Ffocal>20mm (Optimal: 20mm-100mm)
Arwydd FideoAnalog
Viewongl ing60°
Disgleirdeb Delwedd6 lefel y gellir eu haddasu
Goleuo4 LED lights, 4 levels adjustable
Graddfa dal dwrIP67 (prob yn unig)
Flippable ImageOes
Dangosydd Pŵer BatriOes
Ffynhonnell Pwer4x 1.5V R6 (AA) batteries
Lliw CynnyrchCoch a Llwyd
Pwysau Net Cynnyrch500g
Maint Cynnyrch196mm x 74mm x 38mm
Table of technical specifications for the UNI-T UT665 endoscope

Image: A detailed table outlining the technical specifications of the UT665 endoscope.

8. Ceisiadau

The UNI-T UT665 Industrial Endoscope is suitable for various inspection tasks across multiple fields:

  • Modurol: Inspecting engine components, exhaust systems, and other vehicle parts.
  • Aelwyd: Checking pipes, drains, and hard-to-reach areas in homes.
  • Peiriannau: Examining internal components of industrial machinery for wear or damage.
  • HVAC: Inspecting ducts, vents, and air conditioning units.
  • Plymio: Visual inspection of pipes and drainage systems.
  • Adeiladu: Checking structural integrity in confined spaces.
Four images depicting various applications of the UT665 endoscope: auto repair, mechanics, conduit inspection, and hard-to-see places

Delwedd: Examples of the UT665 endoscope being used in auto repair, mechanical inspections, conduit checks, and other difficult-to-access locations.

UNI-T UT665 endoscope inspecting an automobile engine bay

Image: The UT665 endoscope being used to inspect components within an automobile engine bay.

UNI-T UT665 endoscope inspecting a pipe or conduit

Image: The UT665 endoscope inspecting the interior of a pipe or conduit.

9. Gwarant a Chefnogaeth

For warranty information and technical support, please refer to the documentation included with your product or contact the manufacturer directly. Keep your purchase receipt as proof of purchase.

© 2023 UNI-T. Cedwir pob hawl.