BTMETER GC-01

BTMETER GC-01 Nuclear Radiation Detector User Manual

Model: GC-01

1. Rhagymadrodd

This manual provides instructions for the BTMETER GC-01 Nuclear Radiation Detector. This device is designed for detecting, measuring, and monitoring radiation levels, including alpha, beta, gamma, and X-ray radiation. It is equipped with a Geiger-Müller tube for sensitive and precise measurements.

2. Cynnyrch Drosview

2.1. Nodweddion Allweddol

  • Equipped with an energy compensation GM tube for sensitive and accurate detection.
  • Measures Dose Equivalent Rates from 0.0-10000µSv/h and Cumulative Dose Equivalent up to 500.0mSv.
  • Detects Beta, Gamma, and X-rays.
  • Adjustable alarm settings for cumulative and current dose equivalent rates with sound, vibration, and flash light alerts.
  • Displays real-time, average, and maximum CPM readings.
  • Five selectable dosage units: µSv/h, µGy/h, mR/h, CPS, CPM.
  • Powered by a 1100mAh USB Type-C rechargeable lithium battery, providing up to 10 hours of operation.
  • Adjustable screen brightness for varied lighting conditions.

2.2. Cydrannau

BTMETER GC-01 Nuclear Radiation Detector with USB-C cable

Delwedd 2.2.1: Blaen view of the BTMETER GC-01 Nuclear Radiation Detector, showing the display, control buttons, and included USB-C charging cable. The device is yellow and black with a clear digital screen.

BTMETER GC-01 Nuclear Radiation Detector dimensions and battery information

Delwedd 2.2.2: Diagram illustrating the dimensions (120mm x 78mm x 27mm) and highlighting the 1100mAh rechargeable lithium battery and USB Type-C charging port. The image also shows the anti-drop and non-slip silicon material of the device casing.

2.3. Beth sydd yn y Bocs

  • BTMETER GC-01 Nuclear Radiation Detector
  • Cebl Codi Tâl USB Math-C
  • Llawlyfr Defnyddiwr (y ddogfen hon)

3. Gosod

3.1. Gwefru Cychwynnol

Before first use, fully charge the device. Connect the supplied USB Type-C cable to the detector's charging port and to a standard USB power adapter (not included). The battery indicator on the display will show charging status. A full charge provides approximately 10 hours of continuous operation.

3.2. Pweru Ymlaen / I ffwrdd

  • I droi ymlaen: Pwyswch a daliwch y Iawn / Pŵer botwm nes bod yr arddangosfa'n goleuo.
  • I ddiffodd y pŵer: Pwyswch a daliwch y Iawn / Pŵer botwm nes bod yr arddangosfa wedi diffodd.

4. Cyfarwyddiadau Gweithredu

4.1. Deall yr Arddangosfa

BTMETER GC-01 Nuclear Radiation Detector display showing readings and features

Delwedd 4.1.1: The main display of the GC-01, showing real-time radiation levels, current alarm settings, cumulative alarm, and various measurement units. Icons for X, Y, β-RAY detection are visible.

The display provides real-time radiation readings, along with average and maximum values. It also shows the cumulative dose equivalent and current alarm settings.

4.2. Dewis Uned

The device supports five dosage units. To change the unit:

  1. Navigate to the 'Set Unit' option in the menu using the navigation buttons.
  2. Gwasgwch OK i ddewis.
  3. Choose from µSv/h, µGy/h, mR/h, CPS, or CPM.
  4. Gwasgwch OK i gadarnhau eich dewis.
BTMETER GC-01 Nuclear Radiation Detector showing unit selection menu

Delwedd 4.2.1: The device display showing the menu for selecting measurement units (µSv/h, µGy/h, mR/h, CPS, CPM) and demonstrating the dimmable brightness feature.

4.3. Gosodiadau Larwm

The GC-01 features adjustable alarm thresholds for both current and cumulative dose equivalent rates. When a threshold is exceeded, the device can alert via sound, vibration, or flashing light.

  1. Access the 'Set Alarm' option in the menu.
  2. Adjust the desired threshold for current dose and cumulative dose using the navigation buttons.
  3. Select the preferred alarm method(s): sound, vibration, or light.
  4. Gwasgwch OK i arbed gosodiadau.
BTMETER GC-01 Nuclear Radiation Detector showing adjustable alarm settings

Delwedd 4.3.1: The device display showing the menu for adjustable alarm settings, including current alarm and cumulative alarm thresholds. Icons for sound, vibration, and LED flash light alarm modes are displayed.

4.4. Clearing Cumulative Dose

To reset the cumulative dose equivalent value, navigate to the appropriate option in the settings menu and confirm the action.

4.5. Addasiad Disgleirdeb

The screen brightness can be adjusted to improve visibility in various lighting conditions. Access the 'Set Disp' (Display Settings) option in the menu to modify brightness levels.

5. cynnal

5.1. Glanhau

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the casing neu arddangosfa.

5.2. Gofal Batri

Er mwyn ymestyn oes y batri, osgoi rhyddhau'r ddyfais yn llwyr yn aml. Os ydych chi'n ei storio am gyfnod hir, gwefrwch y batri i tua 50% ac ailwefrwch bob ychydig fisoedd.

5.3. Storio

Store the detector in a cool, dry place away from direct sunlight and extreme temperatures. Keep it away from strong magnetic fields and corrosive substances.

6. Datrys Problemau

6.1. Device Does Not Turn On

  • Gwnewch yn siŵr bod y batri wedi'i wefru. Cysylltwch y ddyfais â ffynhonnell bŵer gan ddefnyddio'r cebl USB-C a gadewch iddi wefru am o leiaf 30 munud cyn ceisio ei throi ymlaen eto.
  • Gwiriwch fod y botwm pŵer wedi'i wasgu a'i ddal yn gywir.

6.2. Readings Appear Slow or Unresponsive

  • The device updates readings every second. In environments with very low radiation levels, changes may not be immediately apparent.
  • Ensure the device is not obstructed or placed in an area that could interfere with its sensor.

6.3. Darlleniadau Anghywir

  • Ensure the device is used within its specified operating temperature and humidity ranges.
  • Avoid exposing the device to strong electromagnetic interference.
  • If persistent issues occur, contact customer support.

7. manylebau

BTMETER GC-01 Nuclear Radiation Detector professional specifications

Delwedd 7.1.1: Detailed specifications of the GC-01, including detector type, detection rays, dose equivalent rate, cumulative dose equivalent, energy range, sensitivity, and dosage units.

SynhwyryddEnergy Compensation GM Tube
Mathau o Belydrau CanfodPelydrau γ, pelydrau x, pelydrau β
Cyfradd Cyfwerth Dos0.0-10000µSv/awr (10mSv/awr)
Cyfwerth Dos Cronnus0.00µSv-500.0mSv
Ystod Ynni48keV-1.5Mev ≤±30% (for 137Csγ)
Sensitifrwydd80CPM/µSv (Ar gyfer Co-60)
Unedau DosµSv/h, µGy/h, mR/h, CPS, CPM
Dull LarwmGolau, Dirgryniad, Sain
Batri1100mAh USB Type-C Rechargeable Lithium Battery
Bywyd BatriHyd at 10 awr (ar ôl gwefru'n llawn)
Dimensiynau120 x 78 x 27mm
Pwysau250g

8. Gwarant a Chefnogaeth

8.1. Gwybodaeth Gwarant

The BTMETER GC-01 Nuclear Radiation Detector comes with a 365-day quality warranty from the date of purchase. This warranty covers manufacturing defects and ensures the product functions as described under normal use.

8.2. Cymorth Technegol

Lifetime technical support is provided for this product. For assistance with setup, operation, troubleshooting, or any other inquiries, please contact BTMETER customer service. Refer to the product packaging or the official BTMETER websafle am fanylion cyswllt.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.