Model: UT251C

1. Cynnyrch Drosview

The UNI-T UT251C is a high-accuracy, high-sensitivity leakage current clamp meter designed for precise measurement of AC leakage current. This instrument is suitable for various applications, including checking leakage current in motors, home appliances, and other electrical equipment, with a measurement capability up to 600A.

Two UNI-T clamp meters, models UT251A and UT251C, displayed side-by-side.

Image: UNI-T UT251A and UT251C models.

2. Nodweddion Allweddol

  • Arddangos: 4-digit LCD digital display with 10000 count.
  • Mesur: Auto range for current measurement.
  • SampCyfradd ling: 2 sampllai yr eiliad.
  • Data Functions: Peaks hold and Data hold capabilities.
  • Storio Data: Stores up to 99 sets of data.
  • Cysylltedd: RS-232 interface for data transmission.
  • Rheoli Pwer: Auto power off feature.
  • Dangosyddion: Overload indication and low battery indication.

3. Beth sydd yn y Bocs

Upon unpacking, please verify that all standard accessories are present:

  • UNI-T UT251C Clamp Mesurydd
  • Llawlyfr Cyfarwyddiadau
  • Batri
  • Charger (if applicable)
  • RS-232 Interface Cable

Os oes unrhyw eitemau ar goll neu wedi'u difrodi, cysylltwch â'ch cyflenwr ar unwaith.

4. Gosod

4.1 Gosod Batri

  1. Ensure the meter is powered off.
  2. Lleolwch glawr adran y batri ar gefn y mesurydd.
  3. Use a suitable screwdriver to open the cover.
  4. Insert the battery, observing the correct polarity (+/-).
  5. Amnewid gorchudd adran y batri a'i ddiogelu gyda'r sgriw.

4.2 Pweru Ymlaen/Diffodd

  • I droi’r mesurydd ymlaen, pwyswch y GRYM botwm.
  • I ddiffodd y mesurydd, pwyswch a daliwch y GRYM button until the display turns off. The meter also features an auto power off function to conserve battery life.

5. Cyfarwyddiadau Gweithredu

5.1 Measuring AC Leakage Current

  1. Pwer ar y mesurydd.
  2. Agorwch y clamp gên trwy wasgu'r sbardun.
  3. Carefully place the conductor (e.g., power cable) within the clamp jaw. Ensure the jaw is fully closed around the conductor. For accurate leakage current measurement, clamp around both the live and neutral conductors of a single-phase circuit, or all phase conductors of a multi-phase circuit.
  4. Read the leakage current value displayed on the LCD screen.
UNI-T clamp meter measuring current on a cable.

Image: Clamp meter in use, measuring current.

5.2 Swyddogaeth Dal Data

I rewi'r darlleniad cyfredol ar yr arddangosfa, pwyswch y DALWCH botwm. Pwyswch ef eto i ryddhau'r daliad ac ailddechrau darlleniadau byw.

5.3 Peak Hold Function

The Peak Hold function captures and displays the maximum peak value of the measured current. Refer to the specific button on your device for activating this feature.

5.4 Storio Data

The meter can store up to 99 sets of measurement data. Consult the detailed manual for specific instructions on how to save and recall data sets using the device's interface.

5.5 RS-232 Data Transmission

The RS-232 interface allows for data transfer to a computer for further analysis or logging. Connect the meter to a computer using the provided RS-232 cable and use compatible software (not included) for data communication.

Video: Demonstration of UNI-T UT251 series clamp meters, including physical features, button operation, and current measurement comparison.

6. cynnal

6.1 Glanhau

Sychwch c y mesuryddasing gyda hysbysebamp lliain a glanedydd ysgafn. Peidiwch â defnyddio sgraffinyddion na thoddyddion. Gwnewch yn siŵr bod y mesurydd yn sych cyn ei storio neu ei ddefnyddio.

6.2 Batri Newydd

When the low battery indicator appears on the display, replace the battery promptly to ensure accurate measurements. Refer to section 4.1 for battery installation instructions.

6.3 Storio

When not in use for extended periods, remove the battery and store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

7. Datrys Problemau

  • No Display/Meter Not Powering On: Gwiriwch osodiad y batri a gwnewch yn siŵr bod digon o wefr ar y batri. Amnewidiwch os oes angen.
  • "OL" Indication (Overload): The measured current exceeds the meter's maximum range. Remove the clamp from the conductor immediately to prevent damage.
  • Darlleniadau Anghywir: Sicrhewch y clamp jaw is fully closed around a single conductor or a bundle of conductors for leakage measurement. Avoid external magnetic fields.
  • Arwydd Batri Isel: Replace the battery as soon as possible to maintain measurement accuracy.

8. manylebau

UNI-T UT251C clamp meter with specifications: Range 0.001mA-600A, Resolution 0.1mA, Clamp Jaw 35mm*40mm.

Image: UNI-T UT251C model with key specifications.

Manyleb Value (UT251C)
Brand UNI-T
Model UT251C
Ffynhonnell Pwer Wedi'i Bweru â Batri
Ystod Presennol 0.001mA ~ 600A
Datrysiad 0.1mA
Dimension of Clamp Gên 35mm * 40mm
Storio Data 99 set
Pwysau Eitem 0.5 Cilogram
Dimensiynau Eitem (L x W x H) 7.87 x 1.97 x 3.94 modfedd
Sgôr Diogelwch CAT III 600V
Detailed specifications table for UNI-T UT251A and UT251C clamp metrau.

Image: Comprehensive specifications for UT251 series.

9. Gwarant a Chefnogaeth

The UNI-T UT251C Current Leakage Clamp Daw'r mesurydd gyda Gwarant 1 mlynedd from the date of purchase. For warranty claims, technical support, or service inquiries, please contact your authorized UNI-T dealer or the manufacturer directly. Please retain your proof of purchase for warranty validation.

© 2023 UNI-T. Cedwir pob hawl.