1. Rhagymadrodd
The UNI-T UT60S is a smart, true RMS digital multimeter designed for accurate and reliable electrical measurements. Featuring 9999 counts, this device can measure AC/DC voltage, AC/DC current, resistance, diode, capacitance, temperature, and frequency. Its fully automatic anti-burn intelligent design helps prevent operational errors and device damage, making it suitable for both professional technicians and everyday users.

Ffigur 1: Blaen view of the UNI-T UT60S Digital Multimeter.
2. Gwybodaeth Diogelwch
Always adhere to safety precautions when using the multimeter. Failure to do so may result in electric shock, injury, or damage to the meter or equipment under test.
- Darllenwch y Llawlyfr: Cyn ei ddefnyddio, darllenwch a deallwch yr holl gyfarwyddiadau a rhybuddion diogelwch yn y llawlyfr hwn yn drylwyr.
- Graddedig Voltage: Peidiwch â chymhwyso mwy na'r cyftage, as marked on the meter, between terminals or between any terminal and earth ground. The UT60S is capable of withstanding a maximum overvoltage impulse of 1000V.
- Archwilio Cyn Defnydd: Before each use, inspect the meter, test leads, and accessories for any damage. Do not use if damaged.
- Proper Terminals: Ensure test leads are connected to the correct input terminals for the measurement function selected.
- Dad-egnïo Cylchdaith: Dad-egniwch y gylched bob amser a rhyddhewch yr holl foltedd ucheltage capacitors before performing resistance, continuity, diode, or capacitance measurements.
- Live Circuit Work: When working on live circuits, work alone as little as possible, and ensure another person is present to provide assistance if needed.
- Amddiffyniad Gorgyfredol: The meter features overcurrent alarms and protection functions. Do not exceed the maximum current ratings for the input terminals.
- Amodau Amgylcheddol: Use the meter only as specified in this manual. Do not use the meter in explosive gas, vapor, or dusty environments.
- Offer Diogelu Personol: Always wear appropriate personal protective equipment (PPE), such as safety glasses and insulated gloves, when working with electrical circuits.
3. Nodweddion Cynnyrch
The UNI-T UT60S Digital Multimeter offers a range of features for versatile and safe electrical testing:
- Arddangosfa 9999 o Gyfrifon: Provides high-resolution measurements for precision.
- Gwir fesur RMS: Ensures accurate readings for non-sinusoidal waveforms.
- Fully Automatic Anti-Burn Design: Intelligent protection against operational errors and potential device damage.
- Wide Measurement Capabilities: Mesurau AC/DC cyftage (up to 1000V), AC/DC current, resistance, diode, capacitance, temperature, and frequency.
- Large LCD Screen with Dual Display: Allows simultaneous display of AC voltage and frequency, enhancing readability.
- Full Button Design: Offers intuitive control and automatic recognition of current input jacks.
- Fast ADC (Analog to Digital Converter): Provides rapid measurement updates (3 times/second).
- Misoperation Protection: Capable of withstanding a maximum overvoltage impulse of 1000V, with overvoltage and overcurrent alarms.
- NCV (Cyfrol Di-gyswllttage) Function: Yn canfod AC cyftage without physical contact, featuring audible and visual alarms for safety.
- Arbed Pwer Awtomatig: Low power consumption (7mA during operation, 5uA in sleep state) and automatic backlight display in dark environments, extending battery life. Automatic shut-down feature.

Figure 2: The UT60S display with 9999 counts for precise readings.
4. Beth sydd yn y Bocs
Wrth agor y pecyn, dylech ddod o hyd i'r eitemau canlynol:
- Multimedr Digidol UNI-T UT60S
- Thermocouple (for temperature measurements)
- Multimeter Test Leads (red and black)
- 1.5V AAA Batteries (pre-installed or included separately)

Figure 3: Contents of the UNI-T UT60S package, including the multimeter, test leads, and thermocouple.
5. Gosod
5.1. Gosod Batri
The UT60S typically uses 1.5V AAA batteries. To install or replace batteries:
- Ensure the multimeter is powered off and test leads are disconnected.
- Lleolwch yr adran batri ar gefn y mesurydd.
- Defnyddiwch dyrnsgriw i agor y clawr batri compartment.
- Insert the AAA batteries, observing correct polarity (+ and -).
- Amnewid gorchudd adran y batri a'i ddiogelu gyda'r sgriw.

Ffigur 4: Cefn view of the UT60S, indicating the battery compartment location.
5.2. Cysylltu Gwifrau Prawf
Connect the test leads to the appropriate input terminals:
- The black test lead (common) should always be connected to the COM terfynell.
- Ar gyfer cyftage, resistance, capacitance, frequency, diode, and continuity measurements, connect the red test lead to the VΩHzCAP terfynell.
- For current measurements (mA/A), connect the red test lead to the mA / A. terfynell.
- For microampere current measurements (μA), connect the red test lead to the μA terfynell.

Figure 5: Input terminals of the UT60S for connecting test leads.
6. Cyfarwyddiadau Gweithredu
The UT60S features a full button design for selecting measurement functions. The meter's intelligent anti-burn design automatically recognizes the input jack and selected function.
6.1. Pŵer Ymlaen / I ffwrdd
Gwasgwch y GRYM button to turn the meter on or off. The meter will automatically shut down after a period of inactivity to save battery life.
6.2. Modd Auto
In Auto mode, the meter automatically identifies the measurement type (voltage, resistance, continuity) and selects the appropriate range. This simplifies operation for general troubleshooting.
6.3. Measuring AC/DC Voltage
I fesur cyftage:
- Cysylltwch dennyn y prawf du â'r COM terfynell a'r prawf coch yn arwain at y VΩHzCAP terfynell.
- Gwasgwch y V~ / Hz button to select AC voltage measurement, or the V= / NCV button for DC voltage. The meter may automatically select the correct mode in Auto range.
- Cysylltwch y stilwyr prawf ar draws y gylched neu'r gydran i'w mesur.
- Darllenwch y cyftage value on the display. For AC voltage, the frequency may also be displayed simultaneously.

Ffigur 6: Mesur cyfaint ACtage and frequency with the UT60S.
6.4. Measuring AC/DC Current
I fesur y presennol:
- PWYSIG: To measure current, the meter must be connected in series with the circuit. Always turn off power to the circuit before connecting the meter.
- Cysylltwch dennyn y prawf du â'r COM terfynell.
- For current up to 10A, connect the red test lead to the mA / A. terminal. For microampere current, connect to the μA terfynell.
- Gwasgwch y ACA/DCA button to select AC or DC current measurement.
- Break the circuit and connect the test leads in series with the load.
- Rhowch bŵer i'r gylched a darllenwch y gwerth cerrynt ar yr arddangosfa.
6.5. Measuring Resistance, Diode, and Continuity
To measure resistance, diode, or continuity:
- Ensure the circuit is de-energized and capacitors are discharged.
- Cysylltwch dennyn y prawf du â'r COM terfynell a'r prawf coch yn arwain at y VΩHzCAP terfynell.
- Gwasgwch y Ω→+ button to cycle through resistance, diode, and continuity functions.
- Cysylltwch y stilwyr prawf ar draws y gydran.
- Read the measurement. For continuity, an audible buzzer will sound if continuity is detected.
6.6. Mesur Cynhwysedd
I fesur cynhwysedd:
- Gwnewch yn siŵr bod y cynhwysydd wedi'i ryddhau'n llwyr cyn profi.
- Cysylltwch dennyn y prawf du â'r COM terfynell a'r prawf coch yn arwain at y VΩHzCAP terfynell.
- Gwasgwch y mV~°C°F button to select temperature measurement.
- Cysylltwch y stilwyr prawf ar draws terfynellau'r cynhwysydd.
- Darllenwch y gwerth cynhwysedd ar yr arddangosfa.

Figure 7: The UT60S performing a capacitance measurement.
6.7. Mesur Tymheredd
I fesur tymheredd:
- Connect the thermocouple to the appropriate input terminals (usually the VΩHzCAP a COM terminals, or dedicated temperature inputs if available).
- Gwasgwch y mV~°C°F button to select temperature measurement.
- Place the thermocouple probe at the point where temperature needs to be measured.
- Read the temperature value on the display in Celsius or Fahrenheit.
6.8. NCV (Non-Contact Voltage) Function
The NCV function allows detection of AC voltage without direct contact with conductors.
- Gwasgwch y V= / NCV botwm i actifadu'r swyddogaeth NCV.
- Move the top of the meter close to the conductor or outlet.
- The meter will provide an audible alarm and visual indication (flashing light) if AC voltage is detected. The intensity of the alarm and light may vary with voltage cryfder.

Figure 8: Using the NCV function to detect live AC voltage.
6.9. Dal Data
Gwasgwch y DALWCH botwm i rewi'r darlleniad cyfredol ar yr arddangosfa. Pwyswch ef eto i ryddhau'r swyddogaeth dal.
6.10. Range Selection
While the meter typically operates in Auto range, you can manually select a range by pressing the YSTOD button. This can be useful for specific applications or to speed up measurements in stable conditions. Press and hold the YSTOD button to return to Auto range.
6.11. USB Communication (if applicable)
The UT60S series may support USB communication for data logging and analysis on a computer. If your model includes this feature, connect the meter to your computer using the provided USB cable and install the UNI-T software. Refer to the software manual for detailed instructions.
Video 1: Demonstration of features like NCV, LoZ, and USB communication on a UNI-T UT161 series multimeter. The UT60S shares similar functionalities.
7. cynnal
7.1. Glanhau
Sychwch gas y mesurydd gyda hysbysebamp lliain a glanedydd ysgafn. Peidiwch â defnyddio sgraffinyddion na thoddyddion. Gwnewch yn siŵr bod y mesurydd yn hollol sych cyn ei ddefnyddio.
7.2. Amnewid Batri
Rhowch y batris newydd yn lle'r rhai eraill pan fydd y dangosydd batri isel yn ymddangos ar yr arddangosfa. Cyfeiriwch at Adran 5.1 am gyfarwyddiadau gosod batris.
7.3. Amnewid Ffiws
If the current measurement function stops working, the fuse may need replacement. Refer to the full user manual for specific fuse ratings and replacement procedures. Always use fuses with the specified voltage a graddfeydd cyfredol.
8. Datrys Problemau
If you encounter issues with your UNI-T UT60S, try the following basic troubleshooting steps:
- Dim Arddangosfa/Pŵer Ymlaen: Gwiriwch osodiad y batri a gwnewch yn siŵr nad yw'r batris wedi'u disbyddu. Amnewidiwch os oes angen.
- Darlleniadau anghywir: Verify that the test leads are correctly connected to the appropriate terminals for the selected function. Ensure the function dial is set correctly. Check for damaged test leads.
- Mesuriad Cyfredol Ddim yn Gweithio: Check the fuse. If blown, replace it with a fuse of the correct rating. Ensure the meter is connected in series with the circuit.
- "OL" neu Arwydd Gorlwytho: This indicates that the measured value is outside the selected range or the maximum capability of the meter. Try selecting a higher range (if in manual range mode) or ensure the component is within the meter's specifications.
- NCV Heb ei Ganfod: Ensure the NCV function is activated and the meter is brought close enough to the AC voltage ffynhonnell.
For more complex issues, refer to the detailed troubleshooting section in the complete user manual or contact UNI-T customer support.
9. manylebau
Key specifications for the UNI-T UT60S Digital Multimeter:
| Nodwedd | Manyleb |
|---|---|
| Cyfrif Arddangos | 9999 |
| Gwir RMS | Oes |
| AC / DC Voltage | Hyd at 1000V |
| AC / DC Cyfredol | Up to 10A (mA/A terminals), Up to 1000μA (μA terminal) |
| Gwrthsafiad | 0.1Ω - 40MΩ |
| Cynhwysedd | 1nF - 4000μF |
| Tymheredd | Yes (with thermocouple) |
| Amlder | Oes |
| Prawf Deuod | Oes |
| Prawf Parhad | Oes |
| NCV (Cyfrol Di-gyswllttage) | Oes |
| Ffynhonnell Pwer | Battery Powered (1.5V AAA batteries) |
| Pwysau Eitem | 370 gram |
| Cydymffurfiaeth Diogelwch | UL 61010-1, IEC 61010-2-030, CAT III 1000V, CAT II 600V |
10. Gwarant a Chefnogaeth
UNI-T provides customer support for their products. If you encounter any problems during use, please contact UNI-T customer service directly via email. They offer 7/24 1-to-1 user support to address your concerns promptly.
For specific warranty details, please refer to the warranty card included with your product or visit the official UNI-T websafle.