1. Gwybodaeth Diogelwch

Gosodiad Proffesiynol Angenrheidiol: This DELLA Mini Split AC system mandates professional installation. It is not designed for DIY installation. Improper installation can lead to serious injury, property damage, or void the warranty.

Always ensure all power connections are turned off before performing any installation or maintenance procedures.

Refer to local electrical codes and regulations for proper wiring and safety standards.

2. Cynnyrch Drosview

The DELLA 20K BTU Dual Zone Mini Split AC Heat Pump (Model 1D2-TL+D99) is an energy-efficient, multi-zone ductless system designed to provide personalized climate control for up to 800 sq. ft. (400 sq. ft. per indoor unit). It features Wi-Fi connectivity and compatibility with smart home assistants like Alexa.

Nodweddion Allweddol:

  • Ynni Effeithlon: 20 SEER2 rating, DC Inverter technology for up to 30% power savings.
  • Dual Zone Comfort: Two 9,000 BTU indoor air handlers with separate controllers for individual room temperature control.
  • Cwmpas Eang: Cools and heats up to 800 sq. ft. (400 sq. ft. per indoor unit).
  • Swyddogaeth Pwmp Gwres: Operates effectively in temperatures as low as -13°F (-25°C).
  • Rheoli Clyfar: Wi-Fi enabled, compatible with Alexa and Google Assistant via the Della+ app.
  • Gweithrediad Tawel: Ultra-silent at only 29 dBa.
  • Moddau Lluosog: 4D air flow (up-down, left-right), I Feel mode, 24-hour timer, sleep mode, eco energy saving mode, multiple fan speeds, turbo function, heating, cooling, and dry mode for dehumidifying.
  • Cyfeillgar i'r amgylchedd: Uses R454B refrigerant.

Cydrannau Cynnyrch:

Diagram showing all components included with the Della Mini Split AC unit.

Disgrifiad o'r Delwedd: A detailed diagram illustrating the various components included with the Della Mini Split AC system. These include the indoor unit, outdoor unit, refrigerant pipes, drain lines, remote control, rubber feet, insulation foam, mounting plate, wall sleeve, plasticine putty, anchors, wall cap, plastic wrap, communication cable, and bracket template.

  • Uned Dan Do
  • Uned Awyr Agored
  • Pibell Rheweiddio
  • Llinellau Drain
  • Rheolaeth Anghysbell
  • Traed Rwber
  • Ewyn Inswleiddio
  • Plât Mowntio
  • Cap Wal
  • Llawes Wal
  • Plasticine Putty
  • Sgriwiau
  • Angorau
  • Lapio plastig
  • Cebl Cyfathrebu
  • Templed Brac

3. Gosod a Gosod

Proper installation is crucial for the optimal performance and longevity of your DELLA Mini Split AC. It is strongly recommended that installation be performed by a qualified HVAC professional.

Ystyriaethau Cyn Gosod:

Cyn dechrau gosod, ailview these critical steps to ensure proper setup:

Disgrifiad o'r Fideo: This video outlines 5 urgent steps to consider before installing your Della Mini Split AC. It covers critical aspects like choosing the correct installation location for both indoor and outdoor units, proper handling of refrigerant pipes to prevent damage, correctly bundling the line set for efficient drainage, the importance of vacuum pumping the refrigerant circuit to remove air and moisture, and ensuring a safe electrical connection with the correct voltage and UL-listed wiring.

  • Lleoliad Gosod: The indoor unit must be at least 6 inches below the ceiling for proper airflow. Verify proper clearances in the user manual's installation preview section. Ensure the wall is sturdy enough to hold the unit's weight without vibration. Keep inlet and outlet clear of obstructions.
  • Pibellau Oergell: Handle with care. Use a bending tool if possible, or bend slowly to avoid damage. Damaged pipes can lead to leaks.
  • Line Set Bundling: After installing the indoor unit, ensure the line set is angled downward and the drain pipe points straight down to allow proper liquid flow and prevent leaks.
  • Pwmpio gwactod: This is a critical step to remove air and moisture for maximum efficiency. Vacuum for at least 15 minutes per line set. For multi-zone systems, vacuum each line set separately. Aim for 500 microns with a micron gauge or -30 PSI with a manifold gauge.
  • Cysylltiad Trydanol: Always verify your connection for safety. Check your home's voltage (110V or 220V) and select the appropriate breaker size and UL-listed wire for the mini split system.

Camau Gosod:

Follow these general steps for installing your Della Mini Split unit. For detailed instructions, consult the full user manual and consider professional assistance.

Disgrifiad o'r Fideo: This video provides a step-by-step guide on how to install a Della Mini Split AC unit. It covers marking and drilling holes using a template, mounting the indoor unit bracket, routing line sets and electrical wiring, connecting refrigerant lines, tightening connections with a torque wrench, and performing the vacuum process. The video concludes with activating the unit and checking for proper operation.

Gwifrau Trydanol:

Ensure all electrical connections are made correctly and safely. Refer to the video below for guidance.

Disgrifiad o'r Fideo: This video demonstrates the correct procedure for wiring your Della Mini Split unit. It emphasizes turning off all power connections before starting, removing electrical compartment covers, and connecting numbered wires (black, white, yellow) to their corresponding terminals on both the indoor and outdoor units, ensuring proper grounding (green to green).

4. Cyfarwyddiadau Gweithredu

Your DELLA Mini Split AC offers various modes and control options for optimal comfort.

Rheolaeth Anghysbell:

The included remote control allows you to easily adjust settings. Familiarize yourself with its functions:

Della Mini Split AC remote control with labeled buttons.

Disgrifiad o'r Delwedd: A close-up image of the Della Mini Split AC remote control, highlighting various buttons and their functions such as On/Off, Temperature Up/Down, Fan Speed, Vertical Swing, Horizontal Swing, Turbo On/Off, ECO Mode, Timer Setting, Display Light, Quiet Mode, Sleep Mode, Vicinity Sensor, and PureClean.

Ap Clyfar a Rheoli Llais:

Control your unit remotely using the Della+ app on your smartphone or through voice commands with Alexa or Google Assistant.

Smartphone screen showing the Della+ app interface for controlling the AC unit.

Disgrifiad o'r Delwedd: A smartphone displaying the Della+ app interface, showing various control options for the AC unit including mode selection, fan speed, sleep mode, and airflow adjustments. The image also indicates compatibility with Google Assistant and Alexa.

The Della+ app allows for advanced features like Geo Location, which automatically adjusts your AC based on your proximity to home.

Disgrifiad o'r Fideo: This video explains how to set up and customize the Geo Location feature in the Della+ app. It demonstrates how to define a preset location on a map and configure the AC unit to automatically turn on or off when you arrive at or leave that location, enhancing convenience and energy efficiency.

Dulliau Gweithredu:

  • Modd Cŵl: Provides cooling to your desired temperature.
  • Modd Gwres: Provides heating, effective down to -13°F (-25°C).
  • Modd Sych: Yn dadleithio'r awyr.
  • Modd Auto: Automatically selects cooling or heating based on the set temperature.
  • Modd ECO: Optimizes energy consumption for savings.
  • Modd Cwsg: Adjusts temperature for comfortable sleep at a quiet 29 dBa.
  • Swyddogaeth Turbo: Yn darparu oeri neu wresogi cyflym.
  • 4D Air Flow: Adjusts airflow direction both horizontally and vertically.

5. cynnal

Regular maintenance ensures efficient operation and extends the lifespan of your DELLA Mini Split AC. Always disconnect power before performing any maintenance.

  • Glanhau hidlydd: Clean the air filters regularly (e.g., every 2-4 weeks, depending on usage) to maintain airflow and efficiency. Refer to the user manual for specific filter removal and cleaning instructions.
  • Glanhau Uned Awyr Agored: Keep the outdoor condenser unit clear of debris, leaves, and other obstructions to ensure proper airflow and heat exchange.
  • Gwasanaethu Proffesiynol: Schedule annual professional maintenance to check refrigerant levels, clean coils, and inspect all components.

6. Datrys Problemau

If you encounter issues with your DELLA Mini Split AC, refer to the following common troubleshooting tips. For complex problems, contact professional support.

  • Uned Ddim yn Troi Ymlaen: Gwiriwch y cyflenwad pŵer, y torrwr cylched, a sicrhewch fod batris y teclyn rheoli o bell yn gweithio'n iawn.
  • Oeri/Gwresogi Annigonol: Verify the set temperature, ensure air filters are clean, and check for any obstructions to airflow. Ensure windows and doors are closed.
  • Sŵn Anarferol: Mae synau bach yn ystod y llawdriniaeth yn normal. Os bydd synau uchel neu anarferol yn digwydd, cysylltwch â gweithiwr proffesiynol.
  • Gollyngiad dŵr: Check the drain hose for blockages or improper angling. Ensure the indoor unit is properly leveled.
  • Codau Gwall: Refer to the specific error code section in your full user manual for detailed explanations and solutions.

7. manylebau

NodweddManylyn
BrandDella
Rhif Model1D2-TL+D99
Gallu20,000 BTU (Dual Zone: 9,000 BTU + 9,000 BTU)
Pŵer Oeri9,000 British Thermal Units (per indoor unit)
Sgôr SEER220 GWELER2
Cyftage208-230V
OergellR-454B
Lefel Sŵn29 dBa (Indoor Unit)
Maes CwmpasUp to 800 Sq. Ft. (400 Sq. Ft. per indoor unit)
Gweithrediad Pwmp GwresI lawr i -13°F (-25°C)
Dull RheoliAp, Rheolydd o Bell, Llais (Alexa, Cynorthwyydd Google)
Dimensiynau Cynnyrch (Dan Do)8.07"D x 31.92"W x 11.49"H
Deunydd CraiddCopr
Maint Ffiws Uchaf25A

8. Gwarant a Chefnogaeth

DELLA offers best-in-class support and lifetime coverage for your product.

  • Gwarant: Gwarant Cyfyngedig.
  • Cefnogaeth i Gwsmeriaid: For any questions or technical assistance, please contact Della customer support.
  • In-house Technicians: Available Monday to Friday.
  • Sgwrs Fyw: 24/7 support available.

Ask a question about this manual