KKmoon KKM828
KKmoon KKM828 2-in-1 Digital Multimeter with Oscilloscope User Manual
Model: KKM828
1. Rhagymadrodd
The KKmoon KKM828 is a versatile 2-in-1 device combining the functionalities of a digital multimeter and an oscilloscope. Designed for efficiency and accuracy, it features a 2.4-inch color display, a 1MHz bandwidth for AC voltage, and a 2.5Msps real-time sampling rate. This manual provides essential information for safe and effective operation of your KKM828 device.
2. Gwybodaeth Diogelwch
Please read and understand all safety instructions before using the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device or other equipment.
- Always ensure the device is in good working condition and free from damage before use.
- Peidiwch â gwneud cais cyftage or current that exceeds the maximum limits specified in the technical specifications.
- Byddwch yn ofalus wrth weithio gyda chyftages above 24V, as they pose a shock hazard. The device will emit an audible warning if the input voltage yn fwy na 24V.
- Ensure the correct function and range are selected before making measurements.
- Amnewidiwch y batris ar unwaith pan fydd y dangosydd batri isel yn ymddangos i sicrhau darlleniadau cywir.
- The device is equipped with double fuses (500mA/250V and 10A/250V) for protection. Do not bypass or use incorrect fuse types.
- Peidiwch â gweithredu'r ddyfais mewn amgylcheddau gwlyb nac awyrgylchoedd ffrwydrol.
- Refer to the "Maintenance" section for proper cleaning and storage procedures.
3. Cynnyrch Drosview
The KKmoon KKM828 integrates a digital multimeter and an oscilloscope into a compact, handheld unit. Key components and features are detailed below.
3.1 Nodweddion Allweddol
- Ymarferoldeb 2-mewn-1: Combines a digital multimeter and an oscilloscope.
- Arddangos: 2.4-inch 320x240 LCM color screen for clear readings and waveform display.
- Oscilloscope Performance: 1MHz ACV bandwidth, 2.5Msps real-time sampcyfradd ling.
- Swyddogaethau Amlfesurydd: Mesurau AC/DC cyftage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode, and continuity.
- Storio Data: Stores up to 100 sets of data and 10 waveforms.
- Rhyngwyneb defnyddiwr: Silicone buttons and a pressure-sensitive dial for precise function selection.
- Ergonomeg: Integrated back bracket for a 60° viewongl ing.
- Diogelwch: Double fuse protection (500mA/250V, 10A/250V) and input voltage rhybudd.
3.2 Cydrannau Dyfais
Refer to the image below for an overview of the device's main components.

Figure 1: KKM828 Product Details. This image highlights the device's HD color screen (01), the function dial for accurate gear changes (02), and the back bracket (03) for easy viewing.
- Sgrin HD: 2.4-inch color screen for clear display of measurements and waveforms.
- Deialu Swyddogaeth: Rotary switch for selecting measurement functions (voltage, current, resistance, etc.) and oscilloscope mode.
- Buttons (F1-F4, R, S): Used for navigating menus, selecting ranges, holding data, and other specific functions.
- Jaciau Mewnbwn: Terminals for connecting test leads for various measurements (e.g., VΩHz, mA, 10A, COM).
- Braced Cefn: Foldable stand for propping up the device at a 60° angle for convenient viewing.
4. Gosod
4.1 Gosod Batri
The KKM828 requires three AA batteries for operation. Ensure the device is powered off before installing or replacing batteries.
- Lleolwch glawr adran y batri ar gefn y ddyfais.
- Open the battery compartment cover by sliding or unscrewing it (if applicable).
- Insert three AA batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Caewch y clawr adran batri yn ddiogel.
4.2 Pweru Ymlaen/Diffodd
To power on the device, rotate the function dial from the "OFF" position to any desired measurement function. To power off, rotate the dial back to the "OFF" position.
5. Cyfarwyddiadau Gweithredu
5.1 Multimeter Functions
The KKM828 offers a comprehensive range of multimeter measurement capabilities. Always connect test leads correctly to the appropriate input jacks (e.g., COM, VΩHz, mA, 10A) for the selected function.
- AC / DC Voltage Mesur: Rotate the dial to the 'V~' or 'V=' position. Connect test leads in parallel with the circuit.
- Mesuriad Cyfredol AC/DC: Rotate the dial to the 'mA~', 'mA=', '10A~', or '10A=' position. Connect test leads in series with the circuit.
- Mesur Gwrthiant: Rotate the dial to the 'Ω' position. Ensure the circuit is de-energized before measuring resistance.
- Mesur Cynhwysedd: Rotate the dial to the 'mF' position. Discharge capacitors before measurement.
- Frequency and Duty Cycle Measurement: Rotate the dial to the 'Hz%' position.
- Prawf Deuod: Rotate the dial to the 'Diode' position. Connect leads across the diode to check forward voltage gollwng.
- Prawf Parhad: Rotate the dial to the 'Continuity' position. The device will beep if resistance is below approximately 50Ω.

Figure 2: Multimeter Measurement Examples. This image illustrates the display during Frequency, Duty Cycle, Diode Test, and Continuity measurements, demonstrating the device's various multimeter functions.
5.2 Swyddogaethau Osgilosgop
The KKM828 features a convenient one-button oscilloscope for waveform analysis.
- Rotate the function dial to the 'Graphical' (oscilloscope) mode.
- Connect the test leads to the circuit where you wish to observe the waveform.
- The device will automatically display the waveform. Use the secondary display at the bottom to view parameters such as Peak-to-Peak voltage (VP-P), average value, RMS value, frequency, time base, and ampgoleu.
- Measurement modes include 'Normal' and 'Automatic'. The device can quickly and accurately measure and display waveforms.

Figure 3: Oscilloscope Waveform Display. This image shows examples of different electrical waveforms (sine, square, pulse, complex) as displayed on the KKM828's oscilloscope screen, along with key measurement parameters.
5.3 Storio a Galw Data
The KKM828 can store up to 100 sets of measurement data and 10 waveforms for later review.
- Specific instructions for saving and recalling data are typically accessed via the function buttons (e.g., 'S' for Save, 'R' for Recall) in relevant measurement modes. Refer to the on-screen prompts for detailed operation.
- The device allows for simultaneous display of historical records and real-time data for easy comparison and analysis.
6. cynnal
6.1 Glanhau
To clean the device, wipe the casing gyda hysbysebamp cloth and a mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from any circuits before cleaning. Do not allow moisture to enter the device.
6.2 Batri Newydd
When the low battery indicator appears on the display, replace the three AA batteries as described in the "Battery Installation" section (4.1). Always use fresh batteries of the same type.
6.3 Storio
When not in use for extended periods, remove the batteries to prevent leakage. Store the device in a cool, dry place within the specified storage environment: -10°C to 60°C, with relative humidity less than 90% RH.
7. Datrys Problemau
This section addresses common issues you might encounter with your KKM828 device.
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw'r ddyfais yn pweru ymlaen. | Batris marw neu wedi'u gosod yn anghywir. | Gwiriwch bolaredd y batri a'i ddisodli â batris AA newydd. |
| No reading or "OL" (Overload) displayed. | Incorrect range selected, open circuit, or input exceeds maximum limit. | Select appropriate range, check test lead connections, ensure circuit is closed. Verify input does not exceed specifications. |
| Mesuriadau anghywir. | Low battery, incorrect connection, or environmental factors. | Replace batteries, re-check test lead connections, ensure operating environment is within specified range. |
| Oscilloscope waveform is unstable or absent. | Poor connection, signal too weak/strong, or incorrect mode. | Ensure secure test lead connection. Adjust amplitude or time base if available (though KKM828 is mostly auto-ranging). Verify signal source. |
| Mae'r ddyfais yn bipio'n barhaus. | Mewnbwn cyftage exceeds 24V (safety warning). | Immediately disconnect the device from the circuit and verify the voltage level. Do not proceed if voltage yn rhy uchel. |
8. manylebau
The following table details the technical specifications of the KKmoon KKM828.
| Paramedr | Gwerth |
|---|---|
| Model | KKM828 |
| Arddangos | 2.4-inch 320 x 240 LCM Color Screen |
| Gwrthiant Mewnbwn | 10 MΩ |
| Math Batri | 3 x batris AA (heb eu cynnwys) |
| Defnydd Pŵer | Tua. 80 mA |
| Operating Time (low brightness) | Tua. 5 awr |
| Storio Data | 100 data sets / 10 waveforms |
| Amgylchedd Gweithredu | 0 ~ 40 °C, <75% RH |
| Amgylchedd Storio | -10 ~ 60 °C, <90% RH |
| Bandwidth (ACV) | 1 MHz |
| Bandwidth (ACA) | 5 KHz |
| Max. Real-time SampCyfradd ling | 2.5 Msps |
| Multimeter Range (DC Voltage) | 400mV / 4V / 40V / 400V / 1000V (Accuracy: 0.75% rdg + 10dgt) |
| Multimeter Range (AC Voltage) | 400mV / 4V / 40V / 400V / 750V (Accuracy: 1.0% rdg + 10dgt) |
| Multimeter Range (DC Current) | 40mA / 400mA / 4A / 10A (Accuracy: 1.2% rdg + 10dgt) |
| Multimeter Range (AC Current) | 40mA / 400mA / 4A / 10A (Accuracy: 1.5% rdg + 10dgt) |
| Multimeter Range (Resistance) | 400.0 Ω ~ 40.00 MΩ (Accuracy: 1.0% rdg + 5dgt) |
| Multimeter Range (Capacitance) | 0.1nF ~ 100, 10.00mF (Accuracy: 2.0% rdg + 10dgt) |
| Multimeter Range (Frequency) | 5Hz ~ 10MHz (Accuracy: 1.0% rdg + 5dgt) |
| Multimeter Range (Duty Cycle) | 0.1 % ~ 99.9 % (Accuracy: 1.0% rdg + 5dgt) |
| Prawf Deuod | Cyftage approx. 5V, Test current approx. 1.5mA |
| Prawf Parhad | Mae'r swnyn yn swnio os yw'r gwrthiant yn < 50Ω |
| Manylebau Ffiws | 500mA / 250V, 10A / 250V |
| Dimensiynau | 160 x 83 x 32 mm |
| Pwysau | 195 g |