MS-BDTP1A

MEET Pen Type Smart Multimeter MS-BDTP1A User Manual

Model: MS-BDTP1A | Brand: MEET

1. Rhagymadrodd

The MEET Pen Type Smart Multimeter is designed for accurate and safe electrical measurements. This device is suitable for both professional and DIY applications, offering features such as auto-ranging voltage measurement, resistance, diode, and continuity testing. It also includes Non-Contact Voltage (NCD) detection and Single Probe Test (SPT) for enhanced utility. The multimeter features Bluetooth connectivity for real-time data transmission to a smartphone or tablet application.

2. Cynnwys Pecyn

Gwiriwch fod yr holl eitemau a restrir isod yn bresennol yn eich pecyn:

  • 1 x Digital Multimeter Detector with attached Test Lead
  • 1 x Operating Manual (this document)
  • 2 x 1.5V Batteries (L1154/LR44/AG13)

3. Nodweddion Cynnyrch

  • Smart Multimeter with TX Function: Connects to Android/iOS apps for real-time measurement data viewing a recordio.
  • Amrediad awtomatig: Automatically selects the correct range for DC/AC voltagmesuriadau e, gwrthiant, a pharhad.
  • High Efficiency Single Probe Test (SPT): Patented numerical digital display for AC voltage in a circuit, improving measurement efficiency.
  • Swyddogaethau Lluosog: Measures AC/DC 300V voltage, continuity, resistance, diode, Non-Contact AC (NCD), and Single Probe Test AC (SPT).
  • Diogelwch Gwell: Features 250V Anti-Burn Protection, dual insulation, and overload protection, meeting CAT III 300V safety standards.
  • Arddangosfa a Phŵer: Digital display with backlight for dimly lit areas, 'OL' over-range display, low battery warning.
  • Cyfleustra: Software calibrated, Freeze/Hold reading function, and auto power-off after 5 minutes of inactivity (can be set to always 'On').
MEET Pen Type Smart Multimeter showing core functions and device overview

Ffigur 1: Drosoddview of the MEET Pen Type Smart Multimeter and its core functions, including AC/DC Voltage, Resistance, Diode, Continuity, NCD, SPT, Data Hold, and Bluetooth integration.

4. Gosod

4.1 Gosod Batri

  1. Lleolwch glawr adran y batri ar gefn y multimedr.
  2. Use a small screwdriver to open the battery compartment.
  3. Insert the two 1.5V (L1154/LR44/AG13) batteries, ensuring correct polarity (+/-).
  4. Amnewid gorchudd adran y batri a'i ddiogelu gyda'r sgriw.
Image showing the battery compartment of the multimeter

Figure 2: Illustration of the battery compartment for installing 1.5V batteries.

4.2 Lawrlwytho Ap a Chysylltiad Bluetooth

  1. Scan the QR code provided in the physical manual (or search for the "MEET Multimeter" app) to download the companion application for your iOS or Android smartphone/tablet.
  2. Sicrhewch fod Bluetooth wedi'i alluogi ar eich dyfais smart.
  3. Turn on the multimeter. The Bluetooth indicator on the multimeter display will activate.
  4. Open the MEET Multimeter app on your smart device and follow the in-app instructions to pair with the multimeter. The connection range is approximately 15 meters.
Image showing the multimeter connected to a smartphone app

Figure 3: The multimeter transmitting data wirelessly to a smartphone application.

5. Cyfarwyddiadau Gweithredu

Before operation, ensure the multimeter is powered on. The device features auto-ranging for most measurements, simplifying usage.

5.1 Pŵer Ymlaen/Diffodd

  • To power on, slide the switch to the 'ON' position.
  • The device will automatically power off after 5 minutes of inactivity to conserve battery. This feature can be disabled if continuous operation is required.
  • To manually power off, slide the switch to the 'OFF' position.

5.2 Mesur AC/DC Cyftage

  1. Ensure the multimeter is in the voltage measurement mode (indicated by 'V' on the display). The device automatically detects AC or DC voltage.
  2. Connect the test lead to the circuit or component you wish to measure.
  3. Darllenwch y cyftage gwerth arddangos ar y sgrin.
Arddangosfa amlfesurydd yn dangos cyfainttage darllen

Figure 4: The multimeter displaying a voltage measurement, indicating 109V.

5.3 Resistance, Diode, and Continuity Testing

  1. Press the 'Select' button to cycle through Resistance (Ω), Diode (→|), and Continuity (•))) modes.
  2. For resistance, connect the test lead across the component. The resistance value will be displayed.
  3. For diode testing, connect the test lead across the diode. The forward voltagBydd e drop yn cael ei arddangos.
  4. For continuity, connect the test lead across the circuit. A buzzer will sound if continuity is detected (typically below 50Ω).

5.4 Non-Contact AC Detection (NCD)

  1. Select the NCD mode.
  2. Bring the tip of the multimeter close to an AC voltage source (e.g., a live wire).
  3. The device will indicate the presence and strength of the AC signal (typically for voltages >25V AC) without direct contact.
Multimeter performing Non-Contact AC Detection

Figure 5: The multimeter's NCD function detecting AC voltage heb gyswllt corfforol.

5.5 Single Probe Test AC (SPT)

  1. Select the SPT mode.
  2. Use the single probe to test AC voltage in a circuit. The patented numerical digital display will show the AC voltage (for voltages >25V AC).

5.6 Dal Data

  • Press the 'Hold' button to freeze the current reading on the display.
  • Press 'Hold' again to release the reading and resume live measurements.

Arddangosiad Cynnyrch

Video 1: Official demonstration of the MEET Pen Type Digital Multimeter, highlighting its features and Bluetooth connectivity. This video is provided by MEET Electronics.

6. manylebau

NodweddManyleb
Arddangosfa Ddigidol3 ½ digits, 1999 counts
AC / DC VoltageAuto-ranging up to 300V
GwrthsafiadAuto-ranging up to 20MΩ
ParhadBuzzer sounds for <50Ω
Gwiriad DeuodYmlaen cyftage drop up to 2.0V
NCD (Non-contact AC Detector)Detects >25V AC with numerical display
SPT (Single Probe Test AC)Detects >25V AC with numerical display
Dal DataOes
Auto Power Off5 minutes (can be disabled)
Relative ReadingOes
Rhwystriant Mewnbwn10MΩ
Anti-Burn Protection (ABP)Up to 250V (AC/DC) on full range
Rhybudd Batri IselYes (<2.6V approx)
TX ConnectivityBluetooth to iOS/Android apps
Tymheredd Gweithredu0°C - 50°C (32°F - 122°F)
Lleithder Gweithredu80% RH ar y mwyaf
Math Batri2 x 1.5V (L1154/LR44/AG13)
Dimensiynau (LxWxD)161 x 24 x 24mm (6.34 x 0.94 x 0.94 modfedd)
ModelMS-BDTP1A
UPC842301100771

7. cynnal

7.1 Glanhau

Wipe the multimeter's exterior with a soft, damp lliain. Peidiwch â defnyddio glanhawyr sgraffiniol na thoddyddion. Gwnewch yn siŵr bod y ddyfais wedi'i diffodd a'i datgysylltu o unrhyw gylchedau cyn glanhau.

7.2 Batri Newydd

When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Refer to section 4.1 for battery installation instructions. Always use two new 1.5V (L1154/LR44/AG13) batteries.

7.3 Storio

If the multimeter will not be used for an extended period, remove the batteries to prevent leakage and damage. Store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Datrys Problemau

ProblemAchos PosiblAteb
Nid yw'r multimedr yn troi ymlaen.Batris marw neu wedi'u gosod yn anghywir.Gwiriwch bolaredd y batri a newidiwch y batris os oes angen.
"OL" (Over Load) displayed.The measured value exceeds the selected range.The multimeter is auto-ranging, but if the value is extremely high, it may still show "OL". Ensure the measurement is within the device's maximum capabilities (e.g., 300V for voltaga).
Darlleniadau anghywir.Low battery, poor connection, or incorrect mode.Replace batteries, ensure test lead has good contact, and verify the correct measurement mode is selected.
Cysylltiad Bluetooth yn methu.Bluetooth disabled on smart device, app not open, or out of range.Ensure Bluetooth is on, the app is running, and the multimeter is within 15m of the smart device. Restart both devices if needed.

9. Gwybodaeth Diogelwch

  • Cadw at godau diogelwch lleol a chenedlaethol bob amser.
  • Do not use the multimeter if it appears damaged or if the test lead is compromised.
  • Peidiwch â chymhwyso mwy na'r cyftage (300V AC/DC) between the terminals or between any terminal and ground.
  • Byddwch yn ofalus iawn wrth weithio gyda chyftaguwchlaw 30V AC RMS, 42V brig, neu 60V DC. Mae'r cyfrolau hyntages yn peri perygl sioc.
  • Ensure the correct function and range are selected before making measurements.
  • The device is rated CAT III 300V. Do not use it for measurements exceeding this category or voltage.
  • Keep fingers behind the finger guards on the test lead during measurements.
  • Replace batteries immediately when the low battery indicator appears to prevent inaccurate readings.

10. Gwarant a Chefnogaeth

MEET Electronics is committed to customer satisfaction. If you encounter any issues or are not 100% satisfied with your product, please contact our support team. We strive to resolve all problems and our professional support team aims to respond within 24 hours.

For support, please refer to the contact information provided with your purchase or visit the official MEET Electronics websafle.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.