1. Rhagymadrodd
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Generic QDX1.5-32-0.75 Submersible Pump. Please read these instructions carefully before using the pump and retain this manual for future reference.
The QDX1.5-32-0.75 is a robust electric submersible pump designed for various water transfer applications, featuring a 1-inch outlet, a maximum head of 30 meters, and a maximum flow rate of 135 liters per minute. It operates on a 220V single-phase 60Hz AC power supply with a 0.75 kW (1 HP) motor.
2. Gwybodaeth Diogelwch
RHYBUDD: Gall methu â dilyn y cyfarwyddiadau diogelwch hyn arwain at sioc drydanol, tân, anaf difrifol, neu farwolaeth.
- Always disconnect the pump from the power supply before performing any maintenance, installation, or cleaning.
- Sicrhewch y cyflenwad pŵer cyftage matches the pump's specifications (220V, 60Hz).
- Do not operate the pump with a damaged power cord or plug. Replace immediately if damaged.
- Never run the pump dry. Ensure it is fully submerged in water during operation to prevent overheating and damage.
- Keep hands, feet, and clothing clear of the pump's intake and outlet during operation.
- Do not use the pump for flammable, corrosive, or explosive liquids. It is designed for clean water only.
- Sicrhewch sylfaen gywir i atal peryglon trydanol.
- Dylid goruchwylio plant i sicrhau nad ydynt yn chwarae gyda'r teclyn.
3. Cynnyrch Drosview
The Generic QDX1.5-32-0.75 Submersible Pump is constructed from durable aluminum, iron, and plastic components, designed for reliable performance in water pumping tasks.

Delwedd 1: Blaen view of the Generic QDX1.5-32-0.75 Submersible Pump, showing the silver-colored pump body, black power cable, blue float switch, and the 1-inch outlet connection.
Nodweddion Allweddol:
- Math o fodur: Tanddwr
- Ffynhonnell Pwer: Electric (220V, 60Hz, Single Phase)
- Allbwn Pwer: 0.75 kW (1 Horsepower)
- Uchafswm Pennaeth: 30 metr
- Cyfradd Llif Uchaf: 135 litr y funud
- Cyflymder: 3600 RPM
- Deunyddiau Adeiladu: Alwminiwm, Haearn, Plastig
- Cydrannau wedi'u Cynnwys: Submersible Pump unit
4. Gosod
- Dadbacio: Carefully remove the pump from its packaging. Inspect for any signs of damage during transit.
- Lleoliad: Position the pump in the desired location, ensuring it is on a stable, level surface and can be fully submerged in the water to be pumped. Avoid placing it directly on mud or sand to prevent clogging.
- Cysylltiad pibell: Connect a suitable discharge hose to the 1-inch outlet of the pump. Secure the hose with a clamp to prevent leaks and disconnections during operation.
- Cysylltiad Trydanol: Ensure the power outlet is properly grounded and matches the pump's electrical requirements (220V, 60Hz). Plug the pump into the power outlet. If a float switch is present, ensure it has free movement.
- boddi: Lower the pump into the water. Ensure the pump is completely submerged before connecting to power or starting operation.
5. Cyfarwyddiadau Gweithredu
- Cychwyn Cychwynnol: After completing the setup steps, plug the pump into the power source. The pump will start automatically if equipped with a float switch and the water level is sufficient.
- Monitro: Observe the pump's operation. Ensure water is being discharged smoothly and there are no unusual noises or vibrations.
- Float Switch Operation: If your pump has a float switch, it will automatically turn the pump on when the water level rises and turn it off when the water level drops below a certain point. Ensure the float switch can move freely.
- Cau i Lawr: To stop the pump, simply unplug it from the power source. If using a float switch, the pump will stop automatically when the water level is low.
- Rhedeg Sych: Avoid dry running the pump. Prolonged operation without water will cause severe damage to the motor and seals.
6. cynnal
Regular maintenance ensures the longevity and optimal performance of your submersible pump.
- Cyn Cynnal a Chadw: Always disconnect the pump from the power supply before any inspection or maintenance.
- Glanhau: Periodically clean the pump's intake screen to remove debris, leaves, or sediment that may obstruct water flow.
- Arolygiad: Regularly inspect the power cord and plug for any signs of damage, cuts, or fraying. Check the discharge hose for blockages or wear.
- Storio: If the pump will not be used for an extended period, clean it thoroughly, drain all water, and store it in a dry, frost-free location.
- Newid arnofio: Ensure the float switch is clean and moves freely.
7. Datrys Problemau
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw pwmp yn dechrau | No power supply; Float switch not activated; Clogged impeller | Check power connection; Ensure water level is high enough for float switch; Clean impeller and intake screen. |
| Pump runs but no water is discharged | Air lock; Clogged intake/discharge hose; Insufficient water level | Raise and lower pump to release air; Clear blockages; Ensure pump is fully submerged. |
| Cyfradd llif is | Partial blockage; Worn impeller; Low voltage | Clean pump and hose; Inspect impeller for wear (contact service); Check power supply voltage. |
| Mae pwmp yn stopio'n annisgwyl | Overheating (thermal overload); Float switch deactivation; Power interruption | Allow pump to cool down; Check water level; Verify power supply. |
8. manylebau
| Manyleb | Gwerth |
|---|---|
| Rhif Model | QDX1.5-32-0.75 |
| Enw Brand | Generig |
| Gwneuthurwr | Alfa |
| Math o Gynnyrch | Pwmp tanddwr |
| Ffynhonnell Pwer | Trydan |
| Cyftage | 220 folt |
| Amlder | 60 Hz |
| marchnerth | 1 HP |
| Cyfradd Llif Uchaf | 135 litr y funud |
| Maximum Lift Height (Head) | 30 o Fesurau |
| Defnyddiau | Alwminiwm, Haearn, Plastig |
| Lliw | Arian |
| Dimensiynau Cynnyrch | 430 x 200 x 260 cm |
| Pwysau Eitem | 14.7 kg |
| Rhif Rhan | BIN_01_107 |
9. Gwarant a Chefnogaeth
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the retailer. Standard return policies, such as a 15-day return period, may apply.