SINOTIMER MC701

MC701 LCD Display Thermostat Heating Temperature Controller User Manual

Model: MC701 | Brand: SINOTIMER

1. Cynnyrch Drosview

The SINOTIMER MC701 is a versatile digital PID temperature controller designed for precise heating and cooling applications. It features an LCD display, supports various input types including PT100 and K-type thermocouples, and provides SSR/Relay output with alarm functions. This manual provides essential information for the safe and effective operation of your MC701 controller.

Blaen view of the MC701 LCD Display Thermostat

Ffigur 1.1: Blaen view of the MC701 controller showing the PV and SV displays, and control buttons.

Ongl view of the MC701 showing the model and input specifications

Ffigur 1.2: Ongl view of the MC701 controller, highlighting the model number (MC701-611) and default input type (K).

2. Nodweddion Allweddol

  • High-precision digital PID temperature control.
  • Dual LCD display for Process Value (PV) and Set Value (SV).
  • Supports multiple input types: K-type thermocouple, PT100 RTD.
  • SSR (Solid State Relay) and Relay output options.
  • Configurable heating and cooling control modes.
  • Integrated alarm functions (ALM1, ALM2).
  • Temperature unit selection: Celsius (°C) or Fahrenheit (°F).

3. Gwybodaeth Diogelwch

Darllenwch a deallwch yr holl gyfarwyddiadau diogelwch cyn eu gosod a'u gweithredu. Gall methu â dilyn y cyfarwyddiadau hyn arwain at sioc drydanol, tân neu anaf difrifol.

  • Sicrhewch y cyflenwad pŵer cyftage matches the controller's specifications (100-240V AC).
  • Dylai'r holl wifrau gael eu perfformio gan drydanwr cymwys.
  • Disconnect power before making any wiring connections or performing maintenance.
  • Do not operate the controller in environments with excessive moisture, dust, or corrosive gases.
  • Sicrhewch awyru priodol i atal gorboethi.
  • This device is not intended for life-support systems or applications where malfunction could lead to severe injury or property damage.

4. Gosod a Gosod

Proper installation is crucial for the accurate and reliable operation of the MC701 controller.

4.1 Mowntio

The MC701 is designed for panel mounting. Ensure adequate space for ventilation and wiring connections.

MC701 controller with mounting clips

Figure 4.1: MC701 controller shown with its included mounting clips for panel installation.

4.2 Gwifro Cysylltiadau

Refer to the wiring diagram on the side of the unit and the instructions below for correct connections. Use appropriate gauge wires for all connections.

Wiring diagram for MC701 temperature controller

Figure 4.2: Detailed wiring diagram on the side of the MC701 unit, showing connections for power, sensor input, SSR, and relay outputs.

  • Power Supply (85-265VAC): Connect to terminals 8 and 9.
  • SSR Output (OUT): Connect to terminals 10 (+) and 11 (-).
  • Relay Output (RELAY): Connect to terminals 13 (NO - Normally Open) and 14 (NC - Normally Closed). Terminal 12 is the common (COM).
  • RTD Input (PT100): Connect to terminals 4 (A), 5 (B), and 6 (B).
  • Thermocouple Input (TC): Connect to terminals 5 (+) and 6 (-).
  • Alarm Outputs (AL1, AL2): Connect to terminals 1, 2, and 3.

5. Cyfarwyddiadau Gweithredu

5.1 Arddangos Drosoddview

The MC701 features a dual display:

  • PV (Process Value): Displays the current measured temperature.
  • SV (Set Value): Displays the desired target temperature.

Goleuadau dangosydd:

  • OUT: Indicates output status (heating/cooling).
  • AT: Auto-tuning indicator.
  • ALM1, ALM2: Alarm indicators.

5.2 Swyddogaethau Botwm

  • SET: Enters parameter setting mode or confirms a setting.
  • < (R/S): Shifts cursor during setting, or resets alarm.
  • V (Down Arrow): Decreases value during setting.
  • ^ (Up Arrow): Increases value during setting.

5.3 Setting the Target Temperature (SV)

  1. Gwasgwch y GOSOD button once. The SV display will start flashing.
  2. Defnyddiwch y ^ a V botymau i addasu'r tymheredd a ddymunir.
  3. Defnyddiwch y < button to shift the cursor for faster adjustment.
  4. Gwasgwch GOSOD again to confirm the new SV and exit the setting mode.

5.4 Advanced Parameter Settings

To access advanced parameters (e.g., PID parameters, alarm settings, input type, temperature unit), press and hold the GOSOD button for several seconds until the first parameter code appears on the PV display.

  • Defnydd ^ a V to navigate through parameters.
  • Gwasgwch GOSOD i view or edit a parameter's value.
  • Addaswch y gwerth gan ddefnyddio ^, V, a <.
  • Gwasgwch GOSOD to save the value and return to the parameter list.
  • To exit advanced settings, press and hold GOSOD again, or wait for a timeout.

6. cynnal

Regular maintenance ensures the longevity and optimal performance of your MC701 controller.

  • Cleaning: Wipe the display and casing gyda lliain meddal, sych. Peidiwch â defnyddio glanhawyr sgraffiniol na thoddyddion.
  • Ventilation: Ensure the ventilation slots on the sides of the unit are not obstructed to prevent overheating.
  • Connections: Periodically check all wiring connections for tightness and signs of wear or corrosion.
  • Storage: If storing the unit, keep it in a dry, dust-free environment within its specified operating temperature range.

7. Datrys Problemau

ProblemAchos PosiblAteb
Display shows "HHHH" or "LLLL"Sensor open circuit or short circuit; temperature exceeds range.Check sensor wiring and connection. Verify sensor type matches setting. Ensure temperature is within range.
Controller not heating/coolingOutput wiring incorrect; SV not set correctly; PID parameters need tuning.Check output wiring (SSR/Relay). Confirm SV is set to desired temperature. Perform auto-tuning if necessary.
Mae tymheredd yn amrywio'n fawrPID parameters not optimized; sensor placement.Perform auto-tuning. Ensure sensor is placed correctly and securely.
No display/Power issueDim cyflenwad pŵer; gwifrau anghywir.Check power connections (terminals 8 & 9). Verify power source is active.

8. manylebau

Ochr view of MC701 showing detailed specifications label

Ffigur 8.1: Ochr view of the MC701 controller displaying its detailed specification label.

ParamedrGwerth
ModelMC701
BrandSINOTIMER
Math MewnbwnK-type Thermocouple (default), PT100 RTD
Amrediad Tymheredd0-1300°C (K-type), configurable for other types
Math o AllbwnRelay / SSR
Cyflenwad Pŵer100-240V AC, 50/60Hz
Math ArddangosLED (PV: Red, SV: Green)
Dosbarth Cywirdeb0.5
Tymheredd Gweithredu0-50°C (approximate, typical for electronics)
Gwlad TarddiadTsieina
UPC780744817811

9. Gwarant a Chefnogaeth

For technical support or warranty inquiries, please contact SINOTIMER customer service through the retailer or the official SINOTIMER website. Please have your product model number (MC701) and purchase details ready.

This product is manufactured by SINOTIMER.

© 2023 SINOTIMER. All rights reserved.

Fersiwn Llawlyfr: 1.0

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.