1. Rhagymadrodd

The INKBIRDPLUS INK-IFT03 is a non-contact infrared thermometer designed for accurate surface temperature measurement across a wide range of applications. This device utilizes laser technology to provide quick and precise readings, making it suitable for cooking, pizza ovens, reptile enclosures, automotive diagnostics, and various industrial and household tasks. It features adjustable emissivity, a backlit LCD, and unit switching between Celsius and Fahrenheit.

INKBIRDPLUS INK-IFT03 Infrared Thermometer being used for various applications like cooking, grilling, and checking engine temperature.

Image 1.1: The INKBIRDPLUS INK-IFT03 Infrared Thermometer is versatile for many uses.

2. Gwybodaeth Diogelwch

Darllenwch yr holl rybuddion diogelwch yn ofalus cyn defnyddio'r cynnyrch hwn.

  • Nid at ddefnydd dynol: This infrared thermometer is designed for measuring surface temperatures of objects only. It is NID intended for measuring human body temperature.
  • Diogelwch laser: The device emits a laser beam. Do not irradiate human eyes directly or indirectly with the laser at any time. Avoid pointing the laser at reflective surfaces that could redirect the beam into eyes.
  • Amgylchedd Gweithredu: Defnyddiwch y ddyfais o fewn ei hystod tymheredd gweithredu penodedig. Osgowch ddod i gysylltiad â thymheredd eithafol, lleithder, neu olau haul uniongyrchol.
  • Glanhau: Do not immerse the device in water. Clean with a damp cloth as instructed in the Maintenance section.
  • Trin Batri: Ensure correct battery polarity. Remove batteries if the device will not be used for an extended period to prevent leakage. Dispose of used batteries responsibly.
A child wearing a face mask with a red circle and cross over the thermometer, indicating 'Not For Human'.

Image 2.1: This device is not intended for measuring human body temperature.

3. Cynnyrch Drosview

Familiarize yourself with the components of your INKBIRDPLUS INK-IFT03 Infrared Thermometer:

Diagram of the INKBIRDPLUS INK-IFT03 Infrared Thermometer with labels for LCD Display, Backlight/Laser Button, Down Key, Mode Switch Button, Up Key, Measurement Trigger, Battery Compartment, IR Sensor, and Infrared Lens.

Image 3.1: Labeled components of the INKBIRDPLUS INK-IFT03.

  1. Sbardun Mesur: Press and hold to activate the laser and take a temperature reading.
  2. Arddangosfa LCD: Shows temperature readings, unit, emissivity, and other indicators.
  3. Backlight/Laser Button: Toggles the backlight and laser on/off. Press and hold for 2-3 seconds to switch between °C and °F.
  4. Allwedd i Fyny: Used to increase values when adjusting settings like emissivity.
  5. Allwedd Down: Used to decrease values when adjusting settings like emissivity.
  6. Botwm Newid Modd: Cycles through various display modes and settings (e.g., Emissivity, High/Low Alarm).
  7. Synhwyrydd IR: Detects infrared radiation emitted by the target object.
  8. Lens isgoch: Focuses infrared radiation onto the sensor.
  9. Adran Batri: Yn gartrefu'r batri 9V.

4. Gosod

4.1 Gosod Batri

The INKBIRDPLUS INK-IFT03 requires one 9V battery (included). To install or replace the battery:

  1. Lleolwch glawr adran y batri ar ddolen y thermomedr.
  2. Agorwch y clawr adran batri.
  3. Insert a new 9V battery, ensuring the correct polarity (+/-).
  4. Caewch y clawr adran batri yn ddiogel.

Mae'r ddyfais bellach yn barod i'w defnyddio.

5. Cyfarwyddiadau Gweithredu

5.1 Mesur Tymheredd Sylfaenol

  1. Pwyntiwch y thermomedr at y gwrthrych targed.
  2. Pwyswch a dal y Sbardun Mesur. The laser pointer will activate, indicating the measurement area.
  3. The temperature reading will appear on the LCD display. For more accurate readings, hold the trigger for 2-3 seconds.
  4. Release the trigger to hold the reading on the display. The device will automatically shut off after 30 seconds of inactivity to conserve battery.

5.2 Cymhareb Pellter i Fan (D:S)

The INK-IFT03 has a Distance to Spot Ratio (D:S) of 16:1. This means that at a distance of 16 units from the target, the measurement spot size will be 1 unit. For example, if you are 16 inches away from an object, the thermometer will measure a 1-inch diameter spot. To ensure accurate readings, make sure the target area is larger than the spot size, especially when measuring from a distance.

Diagram illustrating the 16:1 Distance to Spot Ratio of the infrared thermometer, showing how the measurement spot size increases with distance.

Image 5.1: Understanding the 16:1 Distance to Spot Ratio.

5.3 Newid Unedau Tymheredd (°C/°F)

I newid rhwng Celsius (°C) a Fahrenheit (°F):

  1. Gyda'r ddyfais wedi'i throi ymlaen, pwyswch a daliwch y Backlight / Botwm Laser for approximately 2-3 seconds.
  2. The unit displayed on the LCD will change.
Two images of the thermometer display, one showing temperature in Celsius (28.9°C) and the other in Fahrenheit (84.0°F), with arrows indicating selectable display.

Image 5.2: Switching between Celsius and Fahrenheit display.

5.4 Adjustable Emissivity

Emissivity (E) is a measure of an object's ability to emit infrared energy. Different materials have different emissivity values. For accurate temperature readings, it is important to adjust the thermometer's emissivity setting to match the target material. The INK-IFT03 has an adjustable emissivity range of 0.1 to 1.0.

To adjust emissivity:

  1. Gwasgwch y Botwm Newid Modd repeatedly until "EMS" appears on the bottom of the LCD display.
  2. Defnyddiwch y Allwedd Up or Allwedd Down to adjust the emissivity value (e.g., 0.95 for most organic materials, 0.98 for ice, 0.94 for oil).
  3. Gwasgwch y Sbardun Mesur i achub y lleoliad a dychwelyd i'r modd mesur.
Two images of the thermometer measuring different surfaces: one measuring oil with Emissivity=0.94, and another measuring ice with Emissivity=0.98, demonstrating adjustable emissivity.

Image 5.3: Adjusting emissivity for different materials like oil and ice.

Refer to the table below for common emissivity values:

DeunyddAllyreddDeunyddAllyredd
Alwminiwm (wedi'i ocsideiddio)0.20-0.40Papur0.90
Brass (oxidized)0.61Tywod0.90
Iron (oxidized)0.78Clai0.92-0.96
Asffalt0.95Dwfr0.93
Concrit0.950.98
Pren0.90Plastig0.95
Rwber0.95Olew0.94
Paent0.93Croen Dynol0.98

5.5 Swyddogaethau Eraill

  • Golau cefn: The LCD screen has a backlight for easy reading in low-light conditions.
  • Dangosydd Batri Isel: An icon will appear on the display when the battery level is low, indicating it's time for replacement.
  • Larwm Tymheredd Uchel/Isel: The device may feature adjustable high and low temperature alarms. Consult the on-screen prompts using the Mode button to set these if available.

6. cynnal

6.1 Glanhau'r Dyfais

I sicrhau darlleniadau cywir ac ymestyn oes eich thermomedr:

  1. Glanhau Lens: The infrared lens is the most delicate part. Clean it carefully using a soft, damp cloth or cotton swab with a small amount of rubbing alcohol. Do not use abrasive cleaners or solvents.
  2. Glanhau Tai: Glanhewch y ddyfais dyfais gydag adamp cloth and mild soap. Do not immerse the device in water.

6.2 Batri Newydd

When the low battery indicator appears on the display, replace the 9V battery as described in Section 4.1. Always use a fresh, high-quality 9V battery.

6.3 Storio

Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for an extended period, remove the battery to prevent leakage.

7. Datrys Problemau

ProblemAchos PosiblAteb
Nid yw dyfais yn troi ymlaenBatri marw neu wedi'i osod yn anghywirAmnewidiwch y batri 9V, gan sicrhau'r polaredd cywir.
Darlleniadau anghywirGosodiad emissivity anghywir
Distance to spot ratio exceeded
Mae'r lens yn fudr
Target object is too small
Adjust emissivity to match the material (Section 5.4).
Move closer to the target object.
Clean the infrared lens (Section 6.1).
Ensure the target is larger than the measurement spot.
"HI" or "LO" displayedTemperature is outside the measurement rangeThe device cannot measure temperatures beyond -50°C~750°C / -58°F~1328°F.
Laser ddim yn gweithioLaser disabled or malfunctionPress the Backlight/Laser button to toggle the laser. If it still doesn't work, contact support.

8. manylebau

NodweddManyleb
Enw ModelINK-IFT03
Amrediad Tymheredd-50°C~750°C/-58°F~1328°F
Cymhareb Smotiau Pellter (D:S)16:1
AllyreddAddasadwy 0.1-1.0
Amser Ymateb0.5 Eiliad
Math ArddangosSgrin LCD gyda Backlight
Ffynhonnell Pwer1 x Batri 9V (wedi'i gynnwys)
Shutdown Awtomatig30 eiliad
Nodweddion ArbennigBacklit, Unit Switch (°C/°F), Low Battery Indicator, High/Low Temp Alarm
DeunyddPlastig
Pwysau Eitem340 g
Technoleg CysyllteddIsgoch
GwneuthurwrINKBIRDPLUS
Gwlad TarddiadTsieina

9. Gwybodaeth Gwarant

INKBIRDPLUS products are manufactured to high-quality standards. This product typically comes with a standard manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official INKBIRDPLUS website for detailed warranty terms and conditions, including duration and coverage specifics. Keep your purchase receipt as proof of purchase for warranty claims.

10. Cefnogaeth

For technical assistance, product inquiries, or warranty claims, please contact INKBIRDPLUS customer support through their official website or the contact information provided in your product packaging. When contacting support, please have your product model (INK-IFT03) and purchase details ready.

Swyddogol Websafle: www.inkbird.com (Note: This is a general Inkbird website, specific support contact may vary by region.)

© 2024 INKBIRDPLUS. Cedwir pob hawl.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.