1. Rhagymadrodd
This manual provides essential information for the safe and efficient operation of your EPEVER 3000W Pure Sine Wave Inverter. This inverter converts 24V DC power to 110V AC power, suitable for various off-grid applications. It features a double closed-loop control algorithm for fast response and load impact resistance, ensuring stable and reliable power output.
Mae nodweddion allweddol yn cynnwys:
- 3000W continuous power output, 6000W surge power for 5 seconds.
- Yn gydnaws â batris lithiwm 24V ac asid plwm.
- Rotatable LCD meter for monitoring and parameter configuration.
- Remote control capability via phone apps and PC software.
- Built-in electronic safeguards for comprehensive protection.

2. Cyfarwyddiadau Diogelwch
Read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Sicrhau sylfaen gywir y gwrthdröydd.
- Do not expose the inverter to rain, snow, spray, or excessive dust.
- Install the inverter in a well-ventilated area to prevent overheating.
- Peidiwch ag agor y gwrthdröydd casing; nid oes unrhyw rannau y gall y defnyddiwr eu gwasanaethu y tu mewn.
- Disconnect all power sources before performing any wiring or maintenance.
- Defnyddiwch fesuryddion gwifren priodol ar gyfer pob cysylltiad i atal gorboethi a sicrhau trosglwyddiad pŵer effeithlon.
- Cadwch blant i ffwrdd o'r gwrthdröydd a'i gysylltiadau.

3. Cydrannau Cynnyrch
Familiarize yourself with the various parts of your EPEVER inverter:

4. Gosod a Gosod
Follow these steps for proper installation of your inverter:
4.1 Mowntio
- Dewiswch leoliad sych, wedi'i awyru'n dda, i ffwrdd o olau haul uniongyrchol a ffynonellau gwres.
- Ensure adequate clearance around the inverter for airflow (minimum 150mm on all sides for air intake and outlet).
- Mount the inverter securely to a stable surface using appropriate fasteners.
4.2 Gwifro Cysylltiadau
The inverter features a push-on terminal design for easy wire installation without a screwdriver for the AC output. For DC input, use the screw terminals.

- Sylfaen: Connect the grounding terminal (10) to an earth ground.
- Mewnbwn DC: Connect the positive (1) and negative (2) DC input terminals to your 24V battery bank. Ensure correct polarity.
- Allbwn AC: Connect your AC loads to the AC outlet (5). The push-on terminals simplify this connection.
- Cysylltiadau Dewisol: Connect the RS485 communication port (6) or USB output port (7) for remote monitoring or charging devices.
4.3 Cydnawsedd Batri
The inverter is compatible with both 24V lithium and lead-acid batteries (AGM/GEL/LFP).

5. Cyfarwyddiadau Gweithredu
5.1 Pweru Ymlaen/Diffodd
- To power on, ensure all connections are secure, then press the inverter switch (9). The LCD will illuminate.
- To power off, press the inverter switch (9) again.
5.2 Arddangosfa a Rheolaethau LCD
The rotatable LCD meter (4) provides real-time status and allows parameter configuration.

5.3 Monitro o Bell
The inverter supports remote control and monitoring via phone applications and PC software using the RS485 communication port (6) or an optional eBox-WIFI-01 module.

5.4 Load Compatibility
The inverter is suitable for a wide range of daily appliances. Ensure the total wattage of connected appliances does not exceed the inverter's rated power.

6. cynnal
Mae cynnal a chadw rheolaidd yn sicrhau perfformiad a hirhoedledd gorau posibl eich gwrthdröydd.
- Glanhau: Glanhewch du allan y gwrthdröydd o bryd i'w gilydd gyda lliain sych. Gwnewch yn siŵr bod agoriadau awyru yn rhydd o lwch a malurion.
- Cysylltiadau: Check all electrical connections regularly to ensure they are tight and free from corrosion.
- Amgylchedd: Maintain a suitable operating environment, avoiding extreme temperatures and humidity.
7. Datrys Problemau
Os byddwch chi'n dod ar draws problemau gyda'ch gwrthdröydd, cyfeiriwch at y problemau a'r atebion cyffredin canlynol:
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw'r gwrthdröydd yn troi ymlaen | No DC input power; Loose battery connections; Low battery voltage | Gwiriwch y cysylltiadau batri a chyftage; Ensure battery is charged; Verify inverter switch is ON. |
| Dim allbwn AC | Overload; Short circuit; Over-temperature; Inverter fault | Reduce load; Check for short circuits in AC wiring; Allow inverter to cool; Check fault indicator on LCD. |
| Fault indicator (red) is on | Internal fault; Input/output protection triggered | Refer to the LCD display for specific error codes if available; Disconnect loads and restart inverter; If fault persists, contact support. |
| Pŵer allbwn isel | Cyfrol batri iseltage; Excessive load; Poor DC connections | Charge battery; Reduce load; Tighten DC connections. |
8. Manylebau Technegol
| Manyleb | Gwerth |
|---|---|
| Brand | ERIOED |
| Enw Model | 3000W |
| Mewnbwn Graddedig Voltage | 24VDC |
| Allbwn Voltage | 110VAC (±3%); 120VAC (-7%~+3%) |
| Amlder Allbwn | 50/60Hz ±0.2% |
| Pwer Allbwn Parhaus | 3000 Wat |
| Peak Output Power (Surge) | 6000 Watts (am 5 eiliad) |
| Electrical Output Waveform | Ton Sine Pur |
| Allbwn USB | 5VDC/Uchafswm.1A |
| RS485 Porth Cyfathrebu | 5VDC / 200mA |
| Mathau Batri Cydnaws | 24V Lithium and Lead-acid battery |
| Nifer yr Allfeydd | 1 |
| Energy Specifications Met | IEC62109, EN61000, RoHS |
| Pwysau Eitem | 23.2 Bunt |
9. Gwybodaeth Gwarant
This EPEVER inverter comes with a Gwarant 1 mlynedd from the date of purchase. The warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications. Please retain your proof of purchase for warranty claims.
10. Cefnogaeth i Gwsmeriaid
For technical assistance, troubleshooting, or warranty inquiries, please contact EPEVER customer support through their official website or the contact information provided with your purchase. When contacting support, please have your product model number (3000W) and purchase details ready.