The CONTEC SP70B Handheld Spirometer is a portable device designed for checking lung conditions. It utilizes an infrared measurement mode to assess various respiratory parameters. This device is suitable for routine testing in hospitals, clinics, and home environments.

Mae nodweddion allweddol yn cynnwys:

  • Measurement of parameters such as FVC (Forced Vital Capacity), FEV1 (Forced Expiratory Volume in 1 second), FEV1/FVC ratio, and PEF (Peak Expiratory Flow).
  • Ability to set up personal information including height, age, and gender for accurate readings.
  • Health status indication based on measured data.
  • Bluetooth transmission for data transfer.
  • Data memory and case review functions for tracking progress.
Contec SP70B Handheld Spirometer front view with display showing readings

Ffigur 1: Blaen view of the CONTEC SP70B Handheld Spirometer, displaying measurement results and control buttons.

2. Gosod

2.1 Gosod Batri

The SP70B Spirometer requires two AAA batteries for operation. These batteries are typically included with the device.

  1. Lleolwch y compartment batri ar gefn y ddyfais.
  2. Agorwch y clawr adran batri.
  3. Mewnosodwch ddau fatri AAA, gan sicrhau'r polaredd cywir (+ a -).
  4. Caewch y clawr adran batri yn ddiogel.

2.2 Mouthpiece Attachment

Attach the disposable mouthpiece to the designated port on the spirometer. Ensure it is firmly seated to prevent air leakage during measurement.

Contec SP70B Handheld Spirometer side view with mouthpiece attached

Ffigur 2: Ochr view of the spirometer showing the mouthpiece attachment point.

2.3 Personal Information Setup

Before first use, or for a new user, it is essential to input personal information to ensure accurate and personalized readings. This typically includes:

  • Uchder
  • Oed
  • Rhyw
  • Ethnicity (if applicable for specific reference values)

Refer to the on-screen menu of the device to navigate to the personal settings and input the required data.

3. Cyfarwyddiadau Gweithredu

3.1 Performing a Spirometry Test

  1. Ensure the device is powered on and a clean mouthpiece is attached.
  2. Sit upright in a comfortable position.
  3. Take a deep breath, filling your lungs completely.
  4. Place your lips tightly around the mouthpiece, ensuring no air escapes.
  5. Exhale as hard and as fast as you can, emptying your lungs completely. Continue exhaling for at least 6 seconds, or until instructed by the device.
  6. Repeat the test as necessary, typically three times, to obtain consistent readings.

The device will display key parameters such as FVC, FEV1, FEV1/FVC, and PEF after each test. It may also provide a health status indication based on these measurements compared to predicted values for your personal information.

3.2 Rheoli Data

The SP70B spirometer features data memory and case review functions. You can browse previous test results directly on the device. For more detailed analysis and long-term tracking, the device supports Bluetooth transmission to compatible software or applications.

Refer to the device's on-screen menu or accompanying software instructions for pairing and data transfer procedures.

4. cynnal

4.1 Cleaning the Device and Mouthpiece

Regular cleaning is essential for hygiene and accurate operation.

  • Corff Dyfais: Sychwch y brif uned gyda meddal, damp lliain. Peidiwch â throchi'r ddyfais mewn dŵr na defnyddio glanhawyr sgraffiniol.
  • Darn y geg: The mouthpiece should be cleaned or replaced after each use, especially if used by multiple individuals. Disposable mouthpieces are recommended. If using a reusable mouthpiece, clean it thoroughly with mild soap and water, rinse, and allow it to air dry completely before storage or next use.
Close-up of a clear plastic spirometer mouthpiece

Ffigur 3: Example of a disposable spirometer mouthpiece.

4.2 Storio

Store the spirometer in a clean, dry place away from direct sunlight, extreme temperatures, and humidity. Remove batteries if the device will not be used for an extended period to prevent leakage.

5. Datrys Problemau

If you encounter issues with your CONTEC SP70B Spirometer, refer to the following common troubleshooting steps:

ProblemAchos PosiblAteb
Nid yw'r ddyfais yn pweru ymlaen.Batris isel neu farw; gosod batris yn anghywir.Amnewidiwch y batris gyda batris AAA newydd; gwnewch yn siŵr bod y polaredd yn gywir.
Darlleniadau anghywir neu anghyson.Improper mouthpiece attachment; incorrect breathing technique; dirty mouthpiece; incorrect personal information settings.Ensure mouthpiece is securely attached; review operating instructions for proper technique; clean or replace mouthpiece; verify personal information.
Problemau cysylltiad Bluetooth.Device not in pairing mode; Bluetooth disabled on receiving device; interference.Ensure spirometer is in Bluetooth pairing mode; enable Bluetooth on your smartphone/computer; move closer to the receiving device; restart both devices.

If the problem persists after attempting these solutions, please contact CONTEC customer support for further assistance.

6. manylebau

ParamedrGwerth
BrandCONTEC
Rhif ModelSP70B
GwneuthurwrContec
Batris2 batris AAA (wedi'u cynnwys)
Memory Sticks1
ASINB09773FDCY
Dyddiad Cyntaf Ar Gael14 Mehefin 2021
Swm Net1.0 cyfrif

7. Gwarant a Chefnogaeth

Specific warranty information for the CONTEC SP70B Handheld Spirometer is typically provided with the product packaging or can be found on the official CONTEC websafle. Cyfeiriwch at yr adnoddau hyn am fanylion ynghylch cwmpas gwarant, telerau ac amodau.

For technical support, service, or inquiries about your device, please contact CONTEC customer service through their official channels. Contact information can usually be found on the manufacturer's websafle neu yn y ddogfennaeth sydd wedi'i chynnwys gyda'ch cynnyrch.

© 2024 CONTEC. Cedwir pob hawl.

At ddibenion gwybodaeth yn unig y mae'r llawlyfr hwn. Gall manylebau newid heb rybudd.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.