1. Gwybodaeth Diogelwch
Please read all safety instructions before operating this device. Failure to follow these instructions may result in electric shock, fire, or other hazards.
- Ensure the power supply matches the device's requirements (120VAC, 60Hz).
- Do not exceed the maximum load of 15A/1875W.
- Keep the controller and probe away from water or excessive moisture, except for the waterproof probe tip.
- Peidiwch â dadosod na newid y ddyfais. Cyfeiriwch yr holl waith cynnal a chadw at bersonél cymwys.
- Always unplug the controller from the power outlet before cleaning or performing maintenance.
- This device is equipped with overload protection. In case of an overload, the power output and screen display will automatically cut off to prevent damage.

Image 1.1: Overload Protection Feature. This image shows the iPower temperature controller with a visual indicator pointing to the power cord, emphasizing the 'OVERLOAD PROTECTED' text. It explains that in case of an overload, the power output and screen display will be cut off.
2. Cynnyrch Drosview
The iPower Professional Digital Heating and Cooling Temperature Controller is designed to maintain precise temperature control for various applications, including seed germination, reptile habitats, brewing, and greenhouse environments. It features dual outlets for simultaneous heating and cooling device control, a digital display, and a waterproof temperature probe.
2.1 Cynnwys Pecyn
- iPower Digital Temperature Controller (Model GLCTRLHEATCOOL15)
- Waterproof Temperature Probe
- Llawlyfr Defnyddiwr
2.2 Nodweddion Allweddol
- Ymarferoldeb Deuol: Controls both heating and cooling devices simultaneously.
- Cywirdeb Uchel: Professional-grade waterproof temperature probe.
- Arddangos Digidol: Dual readouts for measured (PV) and set (SV) temperatures.
- Dewis Uned: Supports both Fahrenheit (°F) and Celsius (°C).
- Gweithrediad Hawdd: Intuitive 6-button interface.
- Diogelu gorlwytho: Enhances safety by cutting power during overloads.

Delwedd 2.1: Blaen View of the iPower Temperature Controller. This image displays the main unit of the iPower temperature controller, showing its digital display, control buttons, heating and cooling outlets, power cord, and the attached temperature probe.

Image 2.2: Independent Heating & Cooling Functionality. This image illustrates how the controller can manage both a heating device (represented by a sun icon) and a cooling device (represented by a snowflake icon) simultaneously through its dedicated outlets.

Image 2.3: LED Display and Power Indicators. This image highlights the clear and easy-to-read LED display of the controller, showing temperature readings and indicating the status of heating and cooling operations.

Image 2.4: Wide Range of Uses. This image displays various applications for the iPower temperature controller, including aquariums, greenhouses, seed germination, and reptile enclosures, demonstrating its versatility.
3. Gosod
3.1 Lleoliad Cychwynnol
Place the controller in a dry, stable location. Ensure adequate ventilation around the unit.
3.2 Mowntio (Dewisol)
The controller can be mounted on a wall using the two keyholes located on the back of the unit. Securely fasten the controller to a suitable surface using appropriate screws (not included).

Image 3.1: Wall Mounting Option. This image shows the iPower temperature controller mounted on a wall, highlighting the keyholes on the back for secure installation.
3.3 Cysylltu'r Archwiliwr
Insert the temperature probe into the designated port on the controller. Position the probe in the environment where temperature monitoring and control are required. Ensure the probe tip is fully immersed or positioned correctly for accurate readings.
3.4 Cysylltu Dyfeisiau
- Plug your heating device into the outlet labeled 'HEATING'.
- Plug your cooling device into the outlet labeled 'COOLING'.
- Plug the controller's power cord into a standard 120VAC, 60Hz electrical outlet.
4. Cyfarwyddiadau Gweithredu
The controller features a 6-button interface for easy programming:
- PŴER: Yn troi'r uned ymlaen / i ffwrdd.
- UP: Increases values or navigates menus.
- I LAWR: Decreases values or navigates menus.
- SET: Yn mynd i mewn i'r modd rhaglennu neu'n cadarnhau gosodiadau.
- CF/ST: Toggles between Celsius and Fahrenheit, or enters specific settings.
- CLR: Clears current input or exits programming mode.
4.1 Pweru Ymlaen/Diffodd
Gwasgwch y GRYM button to turn the controller on. Press and hold the GRYM button for approximately 3 seconds to turn it off.
4.2 Darlleniadau Arddangos
- PV (Gwerth Proses): Displays the current measured temperature by the probe.
- SV (Gwerth Gosodedig): Displays the target temperature you have set.
4.3 Setting Temperature Units (°F/°C)
Gwasgwch y CF/ST button to toggle the temperature display between Fahrenheit (°F) and Celsius (°C).
4.4 Setting the Target Temperature (SV)
- Gwasgwch y GOSOD botwm unwaith. Bydd yr arddangosfa SV yn dechrau fflachio.
- Defnyddiwch y UP or I LAWR buttons to adjust the target temperature to your desired value.
- Gwasgwch y GOSOD button again to confirm the setting and exit programming mode.
4.5 Heating and Cooling Operation
Once the target temperature (SV) is set, the controller will automatically activate the heating or cooling outlet based on the current measured temperature (PV) and the set differential (hysteresis, typically pre-set). If PV is below SV, the heating outlet activates. If PV is above SV, the cooling outlet activates.
5. cynnal
5.1 Glanhau
- Always unplug the controller before cleaning.
- Wipe the controller's surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- The temperature probe can be cleaned with a damp cloth. Ensure it is dry before re-inserting into any environment.
5.2 Storio
When not in use, store the controller in a cool, dry place, away from direct sunlight and extreme temperatures.
6. Datrys Problemau
If you encounter issues with your iPower Temperature Controller, refer to the following common problems and solutions:
| Problem | Achos Posibl | Ateb |
|---|---|---|
| Nid yw'r rheolwr yn pweru ymlaen. | No power supply; Power button not pressed correctly. | Ensure the controller is securely plugged into a live outlet. Press and hold the GRYM botwm am 3 eiliad i'w droi ymlaen. |
| Controller does not turn on automatically after a power outage. | This model requires manual restart after power interruption. | Ar ôl pŵer i chitage, manually press and hold the GRYM button for 3 seconds to restart the unit. |
| Heating/Cooling device not activating. | Device not plugged in; Temperature not within activation range; Controller overload. | Check if the device is properly plugged into the correct outlet. Verify the set temperature (SV) and current temperature (PV). Check for overload condition. |
| Darlleniadau tymheredd anghywir. | Probe improperly placed; Damaged probe. | Ensure the probe is correctly positioned and clean. If readings remain inaccurate, the probe may need replacement. |
| Controller trips circuit breaker. | Overload; Faulty device connected. | Sicrhewch y cyfanswm wattage of connected devices does not exceed 1875W. Test devices individually to identify a faulty one. |
7. manylebau
| Nodwedd | Manyleb |
|---|---|
| Rhif Model | GLCTRLHEATCOOL15 |
| Graddedig Voltage | 120VAC, 60Hz |
| Llwytho Uchafswm | 15A / 1875W, 1/2HP, TV-5 |
| Probe Working Temperature | -58 i 230°F (-50 i 110°C) |
| Controller Working Temperature | -40 i 176°F (-40 i 80°C) |
| Dimensiynau Cynnyrch | 8.27 x 6.15 x 2.36 modfedd |
| Pwysau Eitem | 1.45 pwys |
| Math Arddangos | LCD |
| Hyd y Cebl Prob | 75 modfedd (tua) |
| Hyd Cebl Pŵer | 75 modfedd (tua) |

Image 7.1: Controller Dimensions and Cable Lengths. This image provides a visual representation of the controller's physical dimensions (4.55" x 4.55" x 1.6") and the lengths of both the probe cable and power cable (75" each).

Image 7.2: Temperature Working Ranges. This image visually represents the working temperature ranges for both the controller (-40 to 176°F) and the probe (-58 to 230°F).
8. Gwarant a Chefnogaeth
iPower products are manufactured to high-quality standards. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official iPower websafle. Cadwch eich prawf prynu ar gyfer hawliadau gwarant.
For further assistance, you may contact iPower customer service through their official channels. Details are typically found on the product packaging or the manufacturer's websafle.