SEBSON IR_OUT_D

SEBSON IR_OUT_D Outdoor Motion Detector User Manual

Model: IR_OUT_D

1. Rhagymadrodd

Thank you for choosing the SEBSON IR_OUT_D Outdoor Motion Detector. This device is designed to provide reliable motion detection for outdoor lighting applications, offering enhanced security and convenience. This manual provides essential information for the safe installation, operation, and maintenance of your motion detector. Please read these instructions carefully before installation and retain them for future reference.

2. Cyfarwyddiadau Diogelwch

  • Installation must be performed by a qualified electrician in accordance with national wiring regulations.
  • Ensure the power supply is disconnected before installation, maintenance, or repair.
  • Do not open or modify the device. Unauthorized modifications may compromise safety and void the warranty.
  • This product is designed for outdoor use with an IP65 rating, protecting against dust and water jets. Ensure proper sealing during installation.
  • Avoid installing the detector near heat sources, air conditioning units, or objects that may cause rapid temperature changes, as this can lead to false triggers.
  • Do not point the sensor directly at sunlight or reflective surfaces.

3. Cynnyrch Drosview

3.1 Nodweddion Allweddol

  • Integrated infrared sensor for targeted detection of people, large animals, and vehicles.
  • IP65 protection rating for outdoor use.
  • Ceiling surface mount design.
  • Adjustable ambient brightness (LUX) and lighting duration (TIME).
  • Wide detection area of 20x4m with a 360° angle.
  • Yn gydnaws â LED lamps and other energy-saving bulbs up to 1000W, and incandescent lamps hyd at 2000W.

3.2 Cydran Cynnyrch

The SEBSON IR_OUT_D motion detector consists of a main housing, an infrared sensor dome, and internal wiring terminals. Adjustment dials for TIME and LUX settings are located on the unit.

SEBSON IR_OUT_D Motion Detector front view gyda manylebau allweddol

Delwedd 1: Blaen view of the SEBSON IR_OUT_D motion detector, highlighting its 360° detection, IP65 rating, LED compatibility up to 1000W, 10 sec - 30 min time setting, 3-2000 LUX brightness range, and 230V operation.

SEBSON IR_OUT_D Motion Detector with detection range and adjustment dials

Delwedd 2: The motion detector showing its maximum detection range of 20m and maximum detection height of 4m. The image also indicates the location of the TIME and LUX adjustment dials.

4. manylebau

Rhif Model IR_OUT_D
Dimensiynau (L x W x H) 10.1 x 10.1 x 5.5 cm
Pwysau 170 gram
Lliw Gwyn
Deunydd Plastig
Math Pwer AC
Cyftage 230 folt
Llwyth Uchaf (Gwynias) 2000 Wat
Max Load (LED/Energy-saving) 1000 Wat
Dull Gosod Mynydd Nenfwd
Cwmpas Canfod max. 20x4m / 360°
Uchder Gosod 4m (min) to 10m (max)
Gosod Amser 10 eiliad i 30 munud
Brightness Setting (LUX) 3-2000 LUX
Graddfa Diogelu IP65
Tymheredd Gweithredu Hyd at 40°C
Technical drawing of SEBSON IR_OUT_D Motion Detector with dimensions

Delwedd 3: Technical drawing showing the dimensions of the motion detector: 101mm x 101mm x 55mm.

5. Gosod

5.1 Lleoliad Mowntio

The motion detector is designed for ceiling surface mounting. Choose a location that provides the desired detection coverage and is free from obstructions. The optimal installation height is between 4 meters and 10 meters to achieve the specified 20x4m detection area.

Diagram illustrating the detection area and installation height of the motion detector

Delwedd 4: Diagram showing the recommended installation height of 4-10m and the detection area of 20m width and 4m depth from the sensor.

5.2 Gwifrau

RHYBUDD: Ensure the main power supply is switched off before commencing any wiring work.

  1. Open the housing of the motion detector carefully.
  2. Connect the power supply wires to the appropriate terminals as shown in the wiring diagram below.
  3. Connect the load (e.g., light fixture) wires to the designated output terminals.
  4. Sicrhewch fod pob cysylltiad yn ddiogel ac wedi'i inswleiddio'n iawn.
  5. Close the housing, ensuring a tight seal to maintain the IP65 rating.
Cefn view of SEBSON IR_OUT_D Motion Detector showing wiring terminals

Delwedd 5: Cefn view of the motion detector, illustrating the wiring terminals for power input and load output. Typically, blue is neutral, brown is live, and red is the switched live to the load.

6. Gweithrediad a Gosodiadau

After successful installation and power-up, the motion detector will enter a warm-up phase for approximately 30-60 seconds. During this time, it may trigger randomly. Once the warm-up is complete, you can adjust the settings using the two dials:

6.1 TIME Setting (Lighting Duration)

Mae'r AMSER dial controls how long the connected light remains on after motion is detected and no further motion is sensed. You can adjust it from approximately 10 seconds to 30 minutes.

  • Turn the dial clockwise for a longer duration.
  • Turn the dial counter-clockwise for a shorter duration.

6.2 LUX Setting (Ambient Brightness)

Mae'r LUX dial determines the ambient light level at which the detector will activate the connected light. This setting allows the light to only turn on when it's dark enough. The range is from 3 LUX (darkness) to 2000 LUX (daylight).

  • Turn the dial towards the symbol lleuad (lower LUX value) for activation only in darker conditions.
  • Turn the dial towards the symbol haul (higher LUX value) for activation even in brighter conditions (e.g., during the day for testing).

7. cynnal

The SEBSON motion detector requires minimal maintenance. To ensure optimal performance:

  • Regularly clean the sensor lens with a soft, damp cloth to remove dust, dirt, or spiderwebs that may obstruct detection. Do not use abrasive cleaners.
  • Periodically check the mounting and wiring connections for any signs of wear or damage.
  • Ensure the area around the sensor remains clear of moving objects (e.g., tree branches) that could cause false triggers.

8. Datrys Problemau

Problem Achos Posibl Ateb
Nid yw'r golau'n troi ymlaen pan ganfyddir symudiad.
  • Dim cyflenwad pŵer.
  • LUX setting is too high (daylight mode).
  • Faulty bulb or wiring.
  • Synhwyrydd wedi'i rwystro.
  • Gwiriwch y cysylltiad pŵer.
  • Adjust LUX dial towards the moon symbol.
  • Check bulb and wiring connections.
  • Cliriwch unrhyw rwystrau o lens y synhwyrydd.
Mae golau yn aros ymlaen yn barhaus.
  • Symudiad cyson yn yr ardal ganfod.
  • TIME setting is too long.
  • Gwall weirio.
  • Adjust sensor angle or sensitivity.
  • Adjust TIME dial for a shorter duration.
  • Gwiriwch gysylltiadau gwifrau.
False triggers (light turns on without apparent motion).
  • Heat sources (e.g., exhaust vents, direct sunlight).
  • Moving objects (e.g., tree branches, small animals).
  • Sensitifrwydd y synhwyrydd yn rhy uchel.
  • Relocate sensor or shield from heat sources.
  • Clear obstructions or adjust detection area.
  • Adjust sensor sensitivity (if available, otherwise adjust angle).

9. Gwarant a Chefnogaeth