BTMETER BT-881E

BTMETER BT-881E Digital Illuminance/Light Meter User Manual

Model: BT-881E

Brand: BTMETER

1. Rhagymadrodd

The BTMETER BT-881E is a digital illuminance meter designed for precise measurement of light intensity. It provides accurate readings in both Lux and Foot Candles (FC) across a wide range, making it suitable for various applications including home, garden, aquarium, plant cultivation, schools, offices, and LED lighting assessments. Its user-friendly design features a rotatable sensor and data recording capabilities for enhanced convenience.

2. Nodweddion Allweddol

  • Cywirdeb Uchel: Provides reliable measurements with an accuracy of +/- 4% readings +/- 0.5% f.s (at 10,000 Lux; 1,000 FC) and +/- 5% readings +/- 10 digits (at 300,000 Lux; 30,000 FC).
  • Ymateb Cyflym: Features a rapid sampling rate of 2-3 times per second, allowing for instant light measurements.
  • Ystod Mesur Eang: Capable of measuring luminance from 0.01 to 300,000 Lux (0.01 to 30,000 Foot Candles) with a resolution of 0.01.
  • Hawdd i'w Ddefnyddio: Equipped with a 270° rotatable light sensor, eliminating the need to reposition the entire meter for different measurement angles.
  • Cofnodi Data: Allows storage of up to 33 sets of readings for later review a dadansoddi.
  • Temperature Testing: Includes functionality for temperature measurement.
  • Relative Measuring Mode: Displays the difference between current and recorded data, useful for comparative analysis.
BTMETER BT-881E Digital Lux Meter with icons illustrating features like data hold, backlight, max/min hold, relative value, data storage, temperature, bar graph, and Lux/FC selection.

Ffigur 1: Drosoddview of BTMETER BT-881E features.

3. Beth sydd yn y Bocs

  • 1 x BTMETER Lux Meter (BT-881E)
  • 1 x Llawlyfr Defnyddiwr

4. Gosod

4.1 Gosod Batri

The BT-881E requires batteries for operation. To install or replace batteries:

  1. Lleolwch y compartment batri ar gefn y ddyfais.
  2. Defnyddiwch sgriwdreifer pen Phillips bach i agor clawr y batri.
  3. Mewnosodwch y batris gofynnol, gan sicrhau polaredd cywir.
  4. Caewch glawr y batri yn ddiogel a thynhau'r sgriw.

Video 1: Battery installation and basic operation demonstration for a similar BTMETER model (BT-881D). The process is identical for the BT-881E.

5. Cyfarwyddiadau Gweithredu

Familiarize yourself with the buttons and display for effective operation.

BTMETER BT-881E Digital Lux Meter with its display showing 'Light ON' and 'Light OFF' states, highlighting the green backlight.

Figure 2: BTMETER BT-881E display with backlight on and off.

5.1 Pŵer Ymlaen/Diffodd

Gwasgwch y Grym botwm (Eicon botwm pŵer) i droi'r ddyfais ymlaen neu i ffwrdd.

5.2 Unit Selection (Lux/FC)

Gwasgwch y Lux/Fc button to switch between Lux and Foot Candle measurement units.

5.3 Golau cefn

Gwasgwch y GOLAU button to toggle the display backlight on or off for visibility in different lighting conditions.

5.4 Dal Data

Gwasgwch y DALWCH botwm i rewi'r darlleniad cyfredol ar yr arddangosfa. Pwyswch eto i'w ryddhau.

5.5 Max/Min Measurement

Gwasgwch y MAX/MIN button to cycle through maximum, minimum, and current readings. This allows you to track the highest and lowest light levels detected during a measurement session.

5.6 Relative Measurement

Gwasgwch y REL button to enter relative measurement mode. This mode displays the difference between the current measurement and a previously recorded reference value.

Video 2: Demonstration of the BTMETER Digital Light Meter in use, showing light level comparisons. Note: This video is from a third-party creator.

6. Dulliau Mesur

The BT-881E supports three primary measurement modes:

  • Min Mode: Displays the lowest light intensity recorded since the mode was activated.
  • Modd Uchaf: Displays the highest light intensity recorded since the mode was activated.
  • Modd Cymharol: Shows the difference between the current light reading and a set reference point.
BTMETER BT-881E display showing Min mode, Max mode, and Relative mode readings.

Figure 3: Illustration of the three measurement modes.

7. Cofnodi Data

The meter can record up to 33 sets of data. To record a reading, press the REC button. To recall recorded data, press the REC button again and use the arrow keys (if available, or cycle through with repeated presses) to navigate through the stored values.

BTMETER BT-881E display showing data hold and multiple recorded data sets.

Figure 4: Data recording and hold functions.

8. Cywirdeb

The BT-881E is equipped with a high-precision photometric sensor for accurate light measurement. It is calibrated to a standard incandescent lamp at a color temperature of 2556K.

  • Accuracy (≤ 10,000 Lux; 1,000 FC): ±4% readings ±0.5% f.s
  • Accuracy (> 10,000 Lux; 1,000 FC): ±5% readings ±10 digits
  • Penderfyniad: 0.01 Lux / FC
Diagram illustrating the relative sensitivity of the photometric sensor across different wavelengths and accuracy specifications.

Figure 5: High-precision photometric sensor and accuracy details.

9. manylebau

NodweddManyleb
Dimensiynau Cynnyrch6.4 x 2.6 x 1.2 modfedd
Pwysau Eitem5.5 owns
Rhif Model yr EitemCA-BT-881 C/D/E (BT-881E variant)
GwneuthurwrBTMETER
Ystod Mesur0.01~300,000 Lux (0.01~30,000 FC)
Datrysiad0.01 Lux / FC
Sensor Rotation270°
Storio DataHyd at 33 set
Diagram showing the dimensions of the BTMETER BT-881E Digital Lux Meter.

Ffigur 6: Dimensiynau'r cynnyrch.

10. Datrys Problemau

If you encounter issues with your BTMETER BT-881E, consider the following common solutions:

  • Dim Problemau Arddangos/Pŵer: Gwiriwch osodiad y batri a gwnewch yn siŵr nad yw'r batris wedi'u disbyddu. Amnewidiwch os oes angen.
  • Darlleniadau Anghywir: Ensure the sensor is clean and unobstructed. Verify that the correct measurement unit (Lux/FC) is selected. Avoid measuring in rapidly changing light conditions if stable readings are required.
  • Arddangosfa Ddim yn Ymateb: Try turning the device off and on again. If the issue persists, remove and reinsert the batteries.

For persistent problems, contact BTMETER customer support.

11. cynnal

To ensure the longevity and accuracy of your BTMETER BT-881E:

  • Glanhau: Gently wipe the device, especially the light sensor, with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Storio: Store the meter in its protective carrying case in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Diogelu Synhwyrydd: Always keep the sensor cap on when the device is not in use to protect the photometric sensor from dust and damage.

12. Gwarant a Chefnogaeth

For information regarding product warranty, technical support, or service, please refer to the official BTMETER websafle neu cysylltwch â'u hadran gwasanaeth cwsmeriaid. Cadwch eich derbynneb prynu fel prawf o brynu ar gyfer hawliadau gwarant.

© 2024 BTMETER. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.