1. Rhagymadrodd
Thank you for choosing the Hilitand KG316T-II 30A Digital Programmable Timer Switch. This device is designed for precise time control of various electrical appliances and equipment, offering up to 16 ON/OFF programs per day or week. Its high-grade industrial chip ensures accurate timing, and the built-in rechargeable battery provides reliable data retention during power outages. Please read this manual thoroughly before installation and operation to ensure safe and efficient use.
2. Gwybodaeth Diogelwch
- Perygl Trydanol: Installation and wiring should only be performed by a qualified electrician or knowledgeable personnel.
- Cyftage Cydnawsedd: Ensure the timer switch's voltage rating (AC-DC 12V for this model) matches your power supply.
- Cynhwysedd Llwyth: Do not exceed the maximum resistive switching capacity of 25A or inductive capacity of 20A. For loads above 25A, an AC contactor must be used.
- Cysylltiadau Diogel: Gwnewch yn siŵr bod yr holl gysylltiadau gwifren yn dynn ac yn ddiogel i atal cysylltiadau rhydd a pheryglon posibl.
- Amgylchedd: Avoid installing the device in areas with excessive moisture, dust, or extreme temperatures outside the operating range (-10°C to 40°C).
3. Cynnyrch Drosview
The Hilitand KG316T-II is a compact and robust digital timer switch. It features an LCD display for easy programming and monitoring, along with intuitive buttons for setting time and programs.

Ffigur 1: Blaen view of the Hilitand KG316T-II Digital Timer Switch, showing the LCD display and control buttons.

Ffigur 2: Manwl view of the timer switch's internal components and labeled features, including the integrated chip, NiMH lithium battery, transformer stabilizer, 30A relay, high current terminal, and capacitive rubber keys.
Nodweddion Allweddol:
- High industrial-grade chip for accurate timing.
- Built-in rechargeable battery for power-off memory (up to 180 days).
- Maximum 16 ON-OFF programs per day or week.
- Self-locking function to prevent accidental operation.
- Capacitive rubber keys for sensitive and durable operation.
- High current terminals for robust connections.
4. manylebau

Figure 3: Image displaying the detailed technical specifications and physical dimensions of the timer switch.
| Priodoledd | Gwerth |
|---|---|
| Brand | Hilitand |
| Model | KG316T-II |
| Deunydd | Plastic case + metal |
| Gweithio Cyftage | AC-DC 12V (Voltage goddefgarwch: ±15%) |
| Cynhwysedd Newid | Resistive 25A, Inductive 20A |
| Defnydd Pŵer | ≤ 2W |
| Nifer y Gosodiadau | 16 times ON and OFF (Day/Week) |
| Gosod Amrediad Amser | 1 munud - 168 awr |
| Time-keeping Error | <0.5s/24h |
| Cof Power-off | 180 diwrnod neu fwy |
| Amgylchedd Gweithredu | -10°C to 40°C, <95%RH |
| Dimensiynau Cynnyrch | 1.77"D x 2.16"L x 3.94"U (45mm D x 55mm L x 100mm U) |
| Pwysau Eitem | 5.3 owns (Tua 150g) |
5. Gosod
5.1 Initial Reset
Upon first use or after a prolonged period without power, the timer may need to be reset. Use a pointed object (like a toothpick) to press the 'C' (Reset) button located on the front panel. This will clear all previous settings and restore the timer to its factory default state.
Video 1: Demonstrates how to reset the timer switch using the 'C' button. This video features a similar model (CN101A) but the reset procedure is identical.
5.2 Gosod yr Amser Cyfredol
To set the current day and time:
- Pwyswch a dal y Cloc button (usually labeled with a clock icon).
- While holding the Clock button, press the D+ button to adjust the current day (MO, TU, WE, TH, FR, SA, SU).
- While holding the Clock button, press the H+ button to adjust the current hour (0-23 for 24-hour format).
- While holding the Clock button, press the M+ button to adjust the current minute (0-59).
- Release the Clock button to save the current time.

Figure 4: Visual guide for setting the current time (24-hour system) on the timer switch.
5.3 Diagram Gwifro
Refer to the following diagram for proper wiring. Ensure all connections are secure and correspond to the labels on the device. For resistive loads above 25A or inductive loads above 7.5A (e.g., lamps above 5A), an external AC contactor is required.

Figure 5: Wiring diagram for a 220V single-phase AC setup, including connections for an optional AC contactor for higher loads. Note: This manual is for the AC-DC 12V model; consult the device's specific wiring labels for your voltage.
6. Cyfarwyddiadau Gweithredu
6.1 Rhaglennu Amseroedd YMLAEN/DIFFODD
The timer switch supports up to 16 ON/OFF programs. To set a program:
- Gwasgwch y P button to enter programming mode. The display will show '1 ON'.
- Defnyddiwch y D+, H+, a M+ buttons to set the desired ON time for the first program. You can select specific days or a block of days using D+.
- Gwasgwch y P botwm eto. Bydd yr arddangosfa yn dangos '1 OFF'.
- Defnyddiwch y D+, H+, a M+ buttons to set the desired OFF time for the first program.
- Repeat steps 1-4 for additional programs (up to 16 ON/OFF pairs).
- Ar ôl gosod yr holl raglenni a ddymunir, pwyswch y Cloc button to exit programming mode and save the settings. The timer will return to normal operation.

Figure 6: Visual guide for setting the 'ON' time for a program.

Figure 7: Visual guide for setting the 'OFF' time for a program.

Figure 8: Guide on how to review and adjust set programs, and switch between ON, OFF, and AUTO modes.
6.2 Modd Llawlyfr
Mae'r LLAWLYFR button allows you to override programmed settings temporarily. Pressing it cycles through different modes:
- AR: Keeps the output permanently ON.
- I FFWRDD: Keeps the output permanently OFF.
- CAR: Follows the programmed ON/OFF schedules.
To temporarily turn off the display and save battery, press and hold the LLAWLYFR button for 5 seconds. To turn it back on, press and hold for another 5 seconds. Settings are retained.
7. cynnal
7.1 Batri Wrth Gefn
The timer switch includes a built-in rechargeable NiMH lithium battery. This battery maintains the time, display, and programmed data for up to 180 days in the event of a power loss. No user maintenance is typically required for this internal battery.
7.2 Glanhau
Clean the exterior of the timer switch with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these may damage the casing neu arddangosfa.
8. Datrys Problemau
8.1 Materion ac Atebion Cyffredin
- Mae'r arddangosfa'n wag: Check the power supply connections. If power is present, the internal battery might be fully discharged. Allow time for it to recharge when connected to power.
- Timer not switching: Verify that the timer is in AWTO mode. Check your programmed ON/OFF times for accuracy. Ensure the load is within the specified capacity.
- Amser anghywir: Reset the current time as described in Section 5.2.
8.2 Codau Gwall
If there are setting errors, the LCD may display the following codes:
- E1: Indicates that the START time has not been set for a program.
- E2: Indicates that the END time has not been set for a program.
To cancel or reset programs if settings are incorrect, press the C/R button. If all buttons are locked (no response), press and hold C/R am 8 eiliad i ddatgloi.
9. Gwarant a Chefnogaeth
Specific warranty details are not provided in the product information. For warranty claims, technical support, or further assistance, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.