Legrand 1597TRW

Legrand 1597TRW Tamper Resistant GFCI Wall Outlet User Manual

Model: 1597TRW

Rhagymadrodd

This manual provides detailed instructions for the safe installation, operation, and maintenance of the Legrand 1597TRW Tamper Resistant GFCI Wall Outlet. This device is part of the radiant collection, designed to offer reliable electrical protection in residential and commercial environments. Please read these instructions thoroughly before beginning installation or use.

Gwybodaeth Diogelwch

WARNING: Risk of electric shock. May cause serious injury or death. Turn off power at the circuit breaker or fuse box before installation.

  • Always disconnect power at the service panel before working with electrical wiring.
  • Installation must be performed by a qualified electrician or in accordance with all local and national electrical codes.
  • Do not install in wet locations unless specifically rated for such use.
  • Gwnewch yn siŵr bod yr holl gysylltiadau gwifrau yn ddiogel ac wedi'u hinswleiddio'n iawn.
  • Test the GFCI outlet monthly to ensure proper operation.

Cynnwys Pecyn

Gwiriwch fod yr holl gydrannau yn bresennol cyn dechrau'r gosodiad:

  • Legrand 1597TRW Tamper Resistant GFCI Wall Outlet (White)
  • Sgriwiau Mowntio
  • Llawlyfr Cyfarwyddiadau (y ddogfen hon)

Note: A screwless wall plate is not included and must be purchased separately.

Gosodiad

Follow these steps for proper installation of your GFCI outlet:

  1. Diffodd Pŵer: Locate the circuit breaker or fuse that supplies power to the outlet box. Turn it off completely. Verify power is off using a voltage profwr.
  2. Dileu Hen Allfa: Carefully remove the existing wall plate and outlet from the electrical box. Disconnect the wires from the old outlet, noting which wires were connected to the "LINE" and "LOAD" terminals.
  3. Adnabod Gwifrau:
    • LINE Wires: These wires bring power from the circuit breaker to the GFCI outlet.
    • LOAD Wires: These wires carry power from the GFCI outlet to other downstream receptacles or devices that you want to protect. If there are no downstream receptacles, cap the LOAD wires individually.
    • Gwifren ddaear: Typically bare copper or green insulated.
  4. Connect Wires to GFCI:
    • Cysylltwch y LLINELL wires to the terminals marked "LINE" on the GFCI outlet.
    • Cysylltwch y LLWYTH wires to the terminals marked "LOAD" on the GFCI outlet.
    • Cysylltwch y gwifren ddaear to the green ground screw.

    Pwysig: The Legrand 1597TRW features a feed-thru wiring configuration that allows the GFCI to protect downstream receptacles. It also prevents line-load reversal miswire, meaning there will be no power to the face or downstream receptacles if wired incorrectly. An auto-ground clip assures a positive ground to a metal box.

  5. Gosodwch yr Allfa: Carefully fold the wires into the electrical box and secure the GFCI outlet to the box using the provided mounting screws.
  6. Gosod Wall Plat: Attach the screwless wall plate (not included) over the GFCI outlet.
  7. Adfer Pwer: Trowch y pŵer yn ôl ymlaen wrth y torrwr cylched.
Legrand 1597TRW GFCI Outlet, front view

Delwedd: Blaen view of the Legrand 1597TRW Tamper Resistant GFCI Wall Outlet. This image shows the two tamper-resistant receptacles, the TEST button (black), and the RESET button (red).

Gweithrediad

The GFCI outlet is designed to protect against electrical shock by quickly shutting off power if a ground fault is detected.

  • Botwm AILOSOD: After installation or a power outage, press the red RESET button to restore power to the outlet.
  • Botwm PRAWF: Press the black TEST button to simulate a ground fault. The GFCI should trip, and power to the outlet will be cut off. This confirms the GFCI is functioning correctly.

Prawf Misol:

It is recommended to test your GFCI outlet monthly to ensure it is providing continuous protection. To test:

  1. Plygiwch alamp or other device into the GFCI outlet and turn it on.
  2. Press the black TEST button. The lamp should turn off, and the red RESET button should pop out.
  3. Press the red RESET button. The lamp should turn back on.
  4. Os bydd y lamp does not turn off or on as described, the GFCI may be faulty and should be replaced.

Cynnal a chadw

The Legrand 1597TRW GFCI outlet requires minimal maintenance. Regular testing is the primary maintenance procedure.

  • Keep the outlet clean and free from dust and debris.
  • Do not paint over the GFCI outlet or its buttons, as this can impair operation.
  • If the GFCI trips frequently without an apparent cause, consult a qualified electrician to inspect your wiring.

Datrys problemau

Problem Achos Posibl Ateb
GFCI will not reset.
  • No power to the GFCI.
  • Canfod nam daear.
  • Line-load reversal miswire.
  • Faulty GFCI.
  • Gwiriwch y torrwr cylched.
  • Unplug all devices from the GFCI and downstream outlets. Try to reset. If it resets, plug devices back in one by one to identify the faulty device.
  • Verify wiring connections (LINE to LINE, LOAD to LOAD).
  • Replace the GFCI.
Mae GFCI yn teithio'n aml.
  • Faulty appliance/device.
  • Moisture in the circuit.
  • Gwifrau wedi'u difrodi.
  • Identify and remove the faulty appliance.
  • Ensure the environment is dry.
  • Consult a qualified electrician to inspect wiring.
Dim pŵer i'r allfa.
  • Baglu GFCI.
  • Torri torrwr cylched.
  • Gwifrau anghywir.
  • Pwyswch y botwm AILOSOD.
  • Gwiriwch ac ailosod y torrwr cylched.
  • Gwiriwch gysylltiadau gwifrau.

Manylebau

  • Model: 1597TRW
  • Brand: Legrand
  • Lliw: Gwyn
  • Ampdileu: 15 Amps
  • Cyftage: 125 folt
  • Cyfanswm Allfeydd Pŵer: 2
  • Math o gysylltydd: Nema 5-15
  • Deunydd: Metel
  • Nodweddion: Tamper Resistant, Auto-Ground Clip, Feed-Thru Wiring, Line-Load Reversal Miswire Prevention
  • UPC: 680147085438
  • ASIN: B079LTP7Y5

Gwarant a Chefnogaeth

Legrand products are designed and manufactured to the highest quality standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official Legrand website. For technical support or further assistance, please contact Legrand customer service.

Contact information for Legrand can typically be found on their official websafle neu becynnu cynnyrch.

© 2024 Legrand. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.