BMC E-20A-H

BMC RESmart GII Auto CPAP E-20A-H with Humidifier User Manual

Model: E-20A-H

1. Rhagymadrodd

This manual provides essential information for the safe and effective operation, setup, and maintenance of your BMC RESmart GII Auto CPAP System E-20A-H with Humidifier. Please read this manual thoroughly before using the device and retain it for future reference. This device is intended for the treatment of Obstructive Sleep Apnea (OSA).

2. Gwybodaeth Diogelwch

Rhybuddion Diogelwch Pwysig:

  • Always disconnect the device from the power supply before cleaning or performing any maintenance.
  • Peidiwch â throchi'r ddyfais mewn dŵr nac unrhyw hylif arall.
  • Use only accessories and parts recommended by BMC.
  • Keep the device away from direct sunlight, heat sources, and sharp objects.
  • Consult your physician or healthcare provider if you experience any unusual symptoms or discomfort during use.
  • Nid yw'r ddyfais hon wedi'i bwriadu ar gyfer cynnal bywyd.

3. Cynnyrch Drosview

The BMC RESmart GII Auto CPAP System E-20A-H is an intelligent device designed for the treatment of Obstructive Sleep Apnea. It features an integrated humidifier for enhanced comfort.

Cydrannau Allweddol:

  • Prif Uned: Houses the motor, control electronics, and display.
  • Lleithydd: Integrated unit with dual water chambers for efficient humidification.
  • Arddangosfa LCD 3.5-modfedd: Provides real-time information and access to settings.
  • Knob Rheoli: Ar gyfer llywio bwydlenni ac addasu gosodiadau.
  • Allfa Awyr: Connects to the CPAP tubing.
  • Cilfach Pwer: Ar gyfer cysylltu'r addasydd pŵer.
  • Slot Cerdyn SD: For compliance data storage and retrieval (iCode II).
  • SpO2 Kit Port (Optional): For real-time blood oxygen saturation and pulse rate monitoring.
BMC RESmart GII Auto CPAP System with Humidifier

An image showing the BMC RESmart GII Auto CPAP device, featuring its main unit, control knob, and integrated humidifier. The device is black with a clear humidifier chamber visible.

4. Gosod

4.1 Dadbacio

  1. Tynnwch yr holl gydrannau o'r pecyn yn ofalus.
  2. Inspect the device and accessories for any signs of damage. Do not use if damaged.

4.2 Pŵer Cysylltu

  1. Connect the power adapter to the power inlet on the back of the device.
  2. Plygiwch y llinyn pŵer i mewn i allfa drydanol addas.

4.3 Filling the Humidifier

  1. Open the humidifier chamber by sliding or lifting the cover.
  2. Fill the water chamber with distilled water up to the maximum fill line. Do not overfill.
  3. Close the humidifier chamber securely.

4.4 Connecting Tubing and Mask

  1. Connect one end of the CPAP tubing to the air outlet on the device.
  2. Connect the other end of the tubing to your prescribed CPAP mask.
  3. Fit the mask comfortably and securely according to its own instructions.

5. Cyfarwyddiadau Gweithredu

5.1 Starting Therapy

  1. Ensure the device is properly set up and connected.
  2. Gwisgwch eich mwgwd.
  3. Press the Start/Stop button (usually the control knob) to begin therapy. The device will automatically start delivering air.

5.2 Addasu Gosodiadau

Use the control knob to navigate the menu on the 3.5-inch LCD display. Press the knob to select an option and rotate to adjust values.

  • Amrediad Pwysedd: 4-20 cm H2O (Auto CPAP adjusts automatically within this range).
  • Ramp Amser: Adjusts the time (0-60 minutes) for the pressure to gradually increase to the prescribed level.
  • Humidification Level: Select from Off or levels 1-5 to control the humidity output.
  • Reslex: Pressure relief feature (Off/1/2/3) for exhalation comfort.
  • Auto On / Off: Can be enabled or disabled (Off by default).

5.3 Stopping Therapy

Press the Start/Stop button again to end therapy. The device will power down.

5.4 iCode II Data Retrieval

Compliance data is encoded by a QR code displayed on the device's screen. Use a compatible application to scan the QR code for quick data retrieval and monitoring.

6. cynnal

Regular cleaning and maintenance are crucial for the optimal performance and longevity of your device.

6.1 Glanhau Dyddiol

  • Humidifier Water Chamber: Empty any remaining water and rinse with distilled water. Allow to air dry.
  • Mwgwd: Wipe down the mask cushion with a damp cloth or specialized CPAP wipes.

6.2 Glanhau Wythnosol

  • Humidifier Water Chamber: Wash with mild soap and warm water. Rinse thoroughly and allow to air dry completely.
  • Tiwbiau CPAP: Wash with mild soap and warm water. Rinse thoroughly and hang to air dry.
  • Hidlydd aer: Inspect the reusable air filter (if applicable). If dirty, rinse under running water and allow to air dry. Replace disposable filters as recommended.

6.3 Gofal Cyffredinol

  • Sychwch y tu allan i'r ddyfais gyda hysbysebamp cloth. Do not use abrasive cleaners or immerse the device.
  • Replace air filters regularly as per manufacturer recommendations or if visibly dirty.

7. Datrys Problemau

Os byddwch chi'n dod ar draws problemau, cyfeiriwch at y problemau a'r atebion cyffredin canlynol:

ProblemAchos PosiblAteb
Dim pŵerPower cord disconnected; Power outageCheck power connections; Restore power supply
Air leak from maskMask not fitted correctly; Mask worn outAdjust mask straps; Replace mask cushion or mask
Dry mouth/throatHumidifier off or set too low; Water chamber emptyIncrease humidification level; Refill water chamber
Mae'r ddyfais yn swnllydAir filter dirty or blocked; Device on an uneven surfaceClean or replace air filter; Place device on a stable, flat surface
Pressure feels too high/lowIncorrect pressure setting; Ramp feature activeConsult your physician for pressure adjustments; Wait for ramp i gwblhau

If the problem persists, contact your healthcare provider or the manufacturer's customer support.

8. manylebau

NodweddManyleb
ModelE-20A-H
ModdCPAP / Auto
Ystod Pwysedd4-20 cm H2O
Pressure Increment0.5 cm H2O
Ramp Amser0-60 munud
ReslexI ffwrdd / 1/2/3
Lefel Sain<30 dBA
Humidification LevelsWedi diffodd / 1-5
ArddangosLCD 3.5-modfedd
Dimensiynau (LxWxH)170x196x118mm (device) / 290x196x134mm (with H60 humidifier)
Pwysau<1.5kg (device) / <2.5kg (with H60 humidifier)
Cyflenwad PŵerInput Range 100-240V AC, 50/60 Hz, 2.0 A max
Storio DataSD Card (iCode II)
Gwlad TarddiadTsieina

9. Gwarant a Chefnogaeth

For warranty information, please refer to the documentation provided with your purchase or contact your retailer. For technical support, service, or questions regarding your BMC RESmart GII Auto CPAP System, please contact the seller or the manufacturer directly.

© 2023 BMC. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.