DIGITEN G1 Water Flow Sensor (Model FL-808) Instruction Manual

Model: FL-808 | Brand: DIGITEN

Rhagymadrodd

This manual provides detailed instructions for the installation, operation, and maintenance of the DIGITEN G1 Water Flow Sensor, Model FL-808. This Hall effect flow sensor is designed for accurate measurement of liquid flow within a range of 1 to 60 liters per minute. Please read this manual thoroughly before use to ensure proper function and safety.

Cynnyrch Drosview

The DIGITEN G1 Water Flow Sensor (Model FL-808) is a robust and reliable device for measuring water flow. It features G1 (0.5 inch) threaded connections for easy integration into various systems. The sensor outputs a square wave pulse signal proportional to the flow rate, making it suitable for microcontrollers and other electronic systems.

Nodweddion Allweddol:

  • Adeiladu Gwydn: Waterproof, heat-resistant, pressure-resistant, and cold-resistant design.
  • Wide Flow Range: Measures flow from 1 to 60 Liters per minute.
  • Gosodiad Hawdd: Simple G1 (0.5 inch) threaded connections.
  • Allbwn pwls: Generates a square wave pulse signal for flow rate calculation.
  • Cydymffurfio â RoHS: Meets environmental standards.

Gwybodaeth Diogelwch

  • Sicrhewch fod y cyflenwad pŵer wedi'i ddatgysylltu cyn gosod neu gynnal a chadw.
  • Do not exceed the maximum operating pressure of 1.75 MPa.
  • Verify correct wiring connections to prevent damage to the sensor or connected equipment.
  • Avoid installing the sensor in locations with extreme vibrations or corrosive environments.
  • This device is intended for water flow measurement. Do not use with other liquids without verifying compatibility.

Cynnwys Pecyn

  • 1 x DIGITEN G1 Water Flow Sensor (Model FL-808)

Manylebau Technegol

ModelFL- 808
DeunyddMetal (Internal components), Plastic (Housing)
Inlet/Outlet Connection SizeG1 (0.5 inch) Threaded
Ystod Cyfradd Llif1 - 60 L/min
Pwysedd Gweithredu Uchaf1.75 MPa (17.5 Bar)
Vol Gweithredutage YstodDC 5 - 24 V
Cyfredol GweithredolCannot exceed 10 mA (at DC 5V)
Signal AllbwnSquare Wave Pulse
Frequency FormulaF = 4.8 * Q (L/min) ± 2%
Output Pulse per LiterApproximately 450 pulses/liter
Tymheredd Gweithredu≤ 80 ° C
Lleithder Gweithredu35% - 90% lleithder cymharol
Tymheredd Storio-25°C i +80°C
Lleithder Storio25% - 95% lleithder cymharol
Gwrthiant Inswleiddio> 100 MΩ
Hyd Cebl15 cm
Pwysau Cynnyrch80 gram

Gosod a Gosod

1. Gosodiad Mecanyddol

The flow sensor features G1 (0.5 inch) male threaded connections on both ends. Ensure the flow direction arrow on the sensor body aligns with the intended water flow in your system. Apply appropriate thread sealant (e.g., PTFE tape) to prevent leaks. Tighten connections securely but do not overtighten.

DIGITEN G1 Water Flow Sensor, front view

Ffigur 1: Blaen view of the DIGITEN G1 Water Flow Sensor, showing the G1 threaded connections and the product label.

Technical drawing of DIGITEN G1 Water Flow Sensor with dimensions

Figure 2: Technical drawing illustrating the dimensions and internal structure of the DIGITEN G1 Water Flow Sensor.

2. Gwifrau Trydanol

The sensor has a 3-wire connection. Connect the wires as follows:

  • Gwifren Goch: VCC (+) - Connect to DC 5V to 24V power supply.
  • Gwifren Ddu: GND (-) - Connect to ground.
  • Gwifren Felen: Signal Output - Connect to your microcontroller or data acquisition system's input pin.

Sicrhewch y cyfaint gweithredutage is within the specified range of DC 5-24V. The current drawn by the sensor should not exceed 10mA at 5V DC.

DIGITEN G1 Water Flow Sensor with red, black, and yellow wires connected

Ffigur 3: Agos view of the sensor's wiring connections: Red (VCC), Black (GND), and Yellow (Signal).

Close-up of the 3-pin connector for the DIGITEN G1 Water Flow Sensor

Ffigur 4: Manwl view of the 3-pin connector attached to the sensor's cable.

Cyfarwyddiadau Gweithredu

Egwyddor Gweithredu

The DIGITEN G1 Water Flow Sensor uses a Hall effect sensor to detect the rotation of an internal turbine. As water flows through the sensor, it spins a turbine, and a magnet attached to the turbine generates a series of electrical pulses. The frequency of these pulses is directly proportional to the flow rate of the water.

Flow Rate Calculation

The output signal is a square wave. The flow rate (Q in L/min) can be calculated from the measured frequency (F in Hz) using the following formula:

F = 4.8 * Q (L/min)

Therefore, to find the flow rate:

Q (L/min) = F / 4.8

The sensor provides approximately 450 pulses per liter of water. The accuracy is ±2%.

DIGITEN G1 Water Flow Sensor showing internal turbine

Ffigur 5: Mewnol view of the sensor, highlighting the turbine mechanism responsible for pulse generation.

DIGITEN G1 Water Flow Sensor with clear label and connections

Figure 6: The sensor with its label clearly visible, detailing model number, working range, and wiring information.

Cynnal a chadw

  • Arolygiad Rheolaidd: Periodically check for any signs of leaks at the connections or damage to the sensor body and wiring.
  • Glanhau: If the sensor's accuracy degrades, it may be due to debris accumulation inside the turbine. Disconnect power and water supply, then carefully remove the sensor for inspection and cleaning. Use a soft brush and clean water to remove any obstructions.
  • Storio: If storing the sensor for an extended period, ensure it is clean, dry, and kept within the specified storage temperature and humidity ranges (-25°C to +80°C, 25%-95% RH).

Datrys problemau

ProblemAchos PosiblAteb
Dim allbwn signal
  • Incorrect wiring (VCC, GND, Signal)
  • Dim cyflenwad pŵer
  • Synhwyrydd camweithio
  • Dim llif dŵr
  • Check wiring against the diagram.
  • Verify power supply (DC 5-24V) is connected and active.
  • Ensure water is flowing through the sensor.
  • Test with a known good sensor if possible.
Inaccurate flow readings
  • Debris inside the sensor
  • Air bubbles in the water line
  • Incorrect frequency calculation formula
  • Sensor installed incorrectly (e.g., against flow direction)
  • Clean the sensor as described in the Maintenance section.
  • Bleed air from the water system.
  • Double-check the calculation formula (F = 4.8 * Q).
  • Verify the flow direction arrow on the sensor.
Gollyngiadau mewn cysylltiadau
  • Insufficient thread sealant
  • Cysylltiadau rhydd
  • Edau wedi'u difrodi
  • Reapply thread sealant (PTFE tape) and retighten.
  • Ensure connections are snug.
  • Inspect threads for damage; replace if necessary.