Philips Lighting ER55LD3WR

Llawlyfr Defnyddiwr Arwydd Allanfa LED Philips Lighting ER55LD3WR

Model: ER55LD3WR

Rhagymadrodd

This manual provides essential information for the safe and efficient use of your Philips Lighting ER55LD3WR LED Exit Sign. Please read these instructions carefully before installation and operation, and retain them for future reference. This product is designed for commercial lighting applications, specifically as a lighted exit sign.

Gwybodaeth Diogelwch

  • Always disconnect power before installing or servicing the unit.
  • Dylai trydanwr cymwys gyflawni'r gosodiad yn unol â chodau trydanol cenedlaethol a lleol.
  • Peidiwch â defnyddio'r cynnyrch hwn at ddibenion heblaw ei ddefnydd arfaethedig.
  • Sicrhewch fod pob cysylltiad yn ddiogel ac wedi'i inswleiddio'n iawn.
  • Cadwch draw oddi wrth ddŵr a lleithder gormodol.

Cynnwys Pecyn

Gwiriwch fod yr holl gydrannau yn bresennol cyn dechrau'r gosodiad:

  • Philips Lighting ER55LD3WR LED Exit Sign unit
  • Mowntio caledwedd (sgriwiau, angorau)
  • Llawlyfr Cyfarwyddiadau (y ddogfen hon)

Gosod a Gosod

The Philips Lighting ER55LD3WR LED Exit Sign is designed for wall mounting. Ensure the mounting surface is suitable to support the weight of the unit.

  1. Paratowch yr Ardal Gosod: Disconnect power to the circuit where the exit sign will be installed.
  2. Mowntio:
    • Identify the desired wall mounting location.
    • Use the provided mounting hardware to securely attach the exit sign to the wall. Ensure the unit is level.
  3. Gwifrau:
    • Connect the building's 120V AC power supply to the corresponding wires on the exit sign. Refer to the wiring diagram inside the unit's housing for specific connections.
    • Sicrhau sylfaen gywir.
    • Connect the internal battery (if not pre-connected). This is crucial for emergency operation.
  4. Cynulliad terfynol: Secure any covers or diffusers.
Philips Lighting ER55LD3WR LED Exit Sign, front view

Ffigur 1: Blaen view of the Philips Lighting ER55LD3WR LED Exit Sign. This image shows the white housing with the red "EXIT" lettering illuminated, indicating its primary function as an emergency egress indicator.

Cyfarwyddiadau Gweithredu

Once installed and power is restored, the Philips Lighting ER55LD3WR LED Exit Sign will operate automatically.

  • Gweithrediad arferol: When AC power is present, the "EXIT" sign will be illuminated by the internal LEDs. The green indicator light on the unit will be ON, signifying operating status.
  • Gweithrediad Brys: In the event of an AC power failure, the unit will automatically switch to battery backup, illuminating the "EXIT" sign for a specified duration (typically 90 minutes).
  • Botwm Prawf: A test button is provided on the unit to verify emergency operation. Press and hold the "Push to Test" button to simulate an AC power failure. The sign should remain illuminated, and the green indicator light will blink, indicating testing. Release the button to return to normal operation.
Philips Lighting ER55LD3WR LED Exit Sign, test button and indicator lights

Ffigur 2: Agos view of the test button and indicator lights on the Philips Lighting ER55LD3WR LED Exit Sign. The green indicator shows operating status (ON for ready, Blinking for testing). The red indicator shows service alerts such as battery, charger board, transformer, or LED strip faults.

Cynnal a chadw

Regular maintenance ensures the reliability and longevity of your LED Exit Sign.

  • Prawf Misol: Press the "Push to Test" button for at least 30 seconds to ensure the battery backup system is functioning. The sign should remain illuminated.
  • Prawf Blynyddol: Disconnect AC power to the unit for 90 minutes to verify the battery can sustain emergency illumination for the required duration.
  • Glanhau: Glanhewch y tu allan i'r uned gyda meddal, damp brethyn. Peidiwch â defnyddio glanhawyr neu doddyddion sgraffiniol.
  • Amnewid Batri: The internal battery has a limited lifespan. If the unit fails to hold a charge or the red "Battery fault" indicator illuminates, the battery may need replacement. Contact qualified service personnel for battery replacement.

Datrys problemau

Cyfeiriwch at y tabl canlynol am broblemau cyffredin a'u datrysiadau.

ProblemAchos PosiblAteb
Sign does not illuminate (AC power present)No AC power; faulty wiring; LED strip faultCheck circuit breaker; verify wiring connections; contact service for LED replacement.
Sign does not illuminate during power outage (emergency mode)Battery not connected; discharged battery; faulty battery; charger board faultEnsure battery is connected; allow 24 hours for initial charge; replace battery; contact service for charger board repair.
Red Service Alert indicator is ONIndicates battery, charger board, transformer, or LED strip fault (refer to unit label)Identify specific fault from unit label; perform monthly/annual tests; contact qualified service personnel.
Green Operating Status indicator is OFF (AC power present)No AC power; internal faultCheck AC power supply; contact qualified service personnel.

Manylebau

NodweddManylyn
Rhif ModelER55LD3WR
BrandGoleuadau Philips
Math o Ffynhonnell GolauLED
Cyftage120 folt
Ffynhonnell PwerTrydan Corded
Math MowntioWal Mount
DeunyddMetel
LliwGwyn
Dimensiynau Cynnyrch4.25 x 6.25 x 4.8 modfedd
Pwysau Eitem4.98 pwys
UPC781370410117

Gwarant a Chefnogaeth

For warranty information or technical support, please contact Philips Lighting customer service. Keep your purchase receipt as proof of purchase.

Gwneuthurwr: Goleuadau Philips

Websafle: Visit the PHILIPS Store on Amazon

© 2023 Philips Lighting. Cedwir pob hawl.